The Resistor,variable,wire Wound,pre, cataloged under National Stock Number 5905-01-019-3462, is classified within Federal Supply Class 5905 (No Item Name Available) of the Electrical and Electronic Equipment Components group. The primary manufacturer of record is Vishay Sprague Inc. Government technical data includes 30 verified specifications, sourced from the Federal Logistics Information System (FLIS). This item has 11 commercial cross-references from 6 manufacturers, enabling identification through both NSN and commercial part number lookups. 12 verified substitutes exist in the FLIS interchangeability database. Current acquisition status: Cancelled.
| Parameter | Value |
|---|---|
| NSN | 5905-01-019-3462 |
| Primary Part Number | 534B5KSS |
| Item Name | Resistor,variable,wire Wound,pre |
| FSC / FSG | 5905 / 59 — No Item Name Available |
| Manufacturer | Vishay Sprague Inc |
| Status | CANCELLED |
| Actuator Type | SINGLE SHAFT |
| Rotary Actuator Travel in Angular Deg | 3600.0 MINIMUM AND 3610.0 MAXIMUM |
| Features Provided | HUMIDITY PROOF |
| Shaft Diameter | 0.2497 INCHES NOMINAL IN |
| Terminal Type and Quantity | 3 TAB, SOLDER LUG |
| Function Characteristic Per Section | SINGLE SECTION LINEAR |
| Shaft Radial Play | 0.003 INCHES IN |
| Lateral Runout | 0.005 INCHES IN |
| Mounting Method | STANDARD BUSHING |
| Maximum Running Torque | 0.40 INCH-OUNCES IN |
| Shaft Runout | 0.003 INCHES IN |
| Screw Thread Quantity Per Inch | 32.0 |
| Shaft End Play | 0.010 INCHES IN |
| Screw Thread Diameter | 0.375 INCHES NOMINAL IN |
| Resistance Tolerance Per Section in Percent | -5.0 TO 5.0 SINGLE SECTION |
| Maximum Stop Torque | 75.00 INCH-OUNCES IN |
| Effective Electrical Rotation in Deg Angular Rotation | 3600.0 MINIMUM AND 3610.0 MAXIMUM |
| Maximum Starting Torque | 0.50 INCH-OUNCES IN |
| Fragility Factor | MODERATELY RUGGED |
| Pilot Diameter Runout | 0.003 INCHES IN |
| Screw Thread Series Designator | UNEF |
| Electrical Resistance Per Section | 5.0 KILOHMS SINGLE SECTION |
| Shaft Length | 0.812 INCHES NOMINAL IN |
| Function Conformity Tolerance Per Section | -0.25 TO 0.25 SINGLE SECTION |
| Shaft Style | ROUND, SLOTTED |
| Power Dissipation Rating Per Section in Watts | 2.0 FREE AIR SINGLE SECTION |
| Reliability Indicator | NOT ESTABLISHED |
| Body Diameter | 0.860 INCHES MINIMUM AND 0.890 INCHES MAXIMUM IN |
| Function Conformity Per Section | SINGLE SECTION INDEPENDENT LINEARITY |
| Mounting Bushing Length | 0.297 INCHES MINIMUM AND 0.327 INCHES MAXIMUM IN |
| Acquisition Status | CANCELLED |
| HAZMAT | No |
| Part Number | Manufacturer |
|---|---|
| 534B5KSS | Vishay Sprague Inc (USA) |
| 534BUSHING5K0HM | Vishay Sprague Inc (USA) |
| 536-2-1-502 | Vishay Sprague Inc (USA) |
| 534-1-1-502 | Vishay Sprague Inc (USA) |
| 534 | Vishay Sprague Inc (USA) |
| 1356AS1187-1 | Naval Air Systems Command Managed Original Design Activity Not Material/parts Supplier (USA) |
| 109201 | Kontron Europe Gmbh (DEU) |
| 534BM502 | Vishay Sprague Inc (USA) |
| 534PANNEAU5K1SECTION | Tekelec Systemes (FRA) |
| 914122202-001 | Cubic Simulation Systems, Inc. (USA) |
| 109201 | Systron-Donner Corp Microwave/instrument Div (USA) |
NSN 5905-01-019-3462 is a Resistor,variable,wire Wound,pre, manufactured by Vishay Sprague Inc, classified under FSC 5905 (No Item Name Available). Status: cancelled.
NSN 5905-01-019-3462 has 11 cross-referenced part numbers: 534B5KSS (Vishay Sprague Inc), 534BUSHING5K0HM (Vishay Sprague Inc), 536-2-1-502 (Vishay Sprague Inc), 534-1-1-502 (Vishay Sprague Inc), 534 (Vishay Sprague Inc) and 6 more.
There are 12 known substitutes for 5905-01-019-3462: 5330-00-162-5961, 5365-00-241-9980, 4130-00-422-5140 and 9 more. Verify interchangeability with system specifications before substitution.
Key specifications for 534B5KSS: Actuator Type: SINGLE SHAFT; Rotary Actuator Travel in Angular Deg: 3600.0 MINIMUM AND 3610.0 MAXIMUM; Features Provided: HUMIDITY PROOF; Shaft Diameter: 0.2497 INCHES NOMINAL IN. 30 total characteristics are documented in the Federal Logistics Information System.
NSN 5905-01-019-3462 is currently cancelled. Check with the Defense Logistics Agency for current availability and authorized substitutes.