The Resistor,variable,wire Wound,pre, cataloged under National Stock Number 5905-00-936-8402, is classified within Federal Supply Class 5905 (No Item Name Available) of the Electrical and Electronic Equipment Components group. The primary manufacturer of record is Trw Inc Trw Intl Trade Government Sales Dept. Government technical data includes 29 verified specifications, sourced from the Federal Logistics Information System (FLIS). This item has 5 commercial cross-references from 4 manufacturers, enabling identification through both NSN and commercial part number lookups. 2 verified substitutes exist in the FLIS interchangeability database. Current acquisition status: Cancelled.
| Parameter | Value |
|---|---|
| NSN | 5905-00-936-8402 |
| Primary Part Number | 1000-502J |
| Item Name | Resistor,variable,wire Wound,pre |
| FSC / FSG | 5905 / 59 — No Item Name Available |
| Manufacturer | Trw Inc Trw Intl Trade Government Sales Dept |
| Status | CANCELLED |
| Actuator Type | SINGLE SHAFT |
| Rotary Actuator Travel in Angular Deg | 3600.0 MINIMUM |
| Body Length | 1.344 INCHES NOMINAL IN |
| Function Conformity Per Section | SINGLE SECTION INDEPENDENT LINEARITY |
| Actuator Travel Control Feature | STOPS |
| Electrical Resistance Per Section | 5.0 KILOHMS SINGLE SECTION |
| Temp Coefficient of Resistance Wire Per Section in Ppm Per Deg Celsius | -20.0 TO 20.0 SINGLE SECTION |
| Terminal Type and Quantity | 3 TURRET |
| Resistance Tolerance Per Section in Percent | -5.0 TO 5.0 SINGLE SECTION |
| Terminal Location | REAR END LOCATION NOT OTHERWISE SPECIFIED |
| Function Characteristic Per Section | SINGLE SECTION LINEAR |
| Ambient Temp in Deg Celsius Per Section at Full Rated Power | 40.0 SINGLE SECTION |
| Power Dissipation Rating Per Section in Watts | 3.0 FREE AIR SINGLE SECTION |
| Ambient Temp in Deg Celsius Per Section at Zero Percent Rated Power | 125.0 SINGLE SECTION |
| Mounting Method | STANDARD BUSHING |
| Reliability Indicator | NOT ESTABLISHED |
| Body Style | CYLINDRICAL BUSHING MOUNTED |
| Screw Thread Series Designator | UNEF |
| Body Diameter | 1.000 INCHES NOMINAL IN |
| Shaft Length | 1.000 INCHES NOMINAL IN |
| Screw Thread Quantity Per Inch | 32.0 |
| Maximum Starting Torque | 2.00 INCH-OUNCES IN |
| Screw Thread Diameter | 0.375 INCHES NOMINAL IN |
| Shaft Diameter | 0.250 INCHES NOMINAL IN |
| Shaft Style | ROUND |
| Mounting Bushing Length | 0.500 INCHES NOMINAL IN |
| Function Conformity Tolerance Per Section | -0.50 TO 0.50 SINGLE SECTION |
| Effective Electrical Rotation in Deg Angular Rotation | 3600.0 NOMINAL |
| Maximum Running Torque | 2.00 INCH-OUNCES IN |
| Acquisition Status | CANCELLED |
| HAZMAT | No |
| Part Number | Manufacturer |
|---|---|
| 1000-5000 | Trw Inc Trw Electronic Components Irc Fixed Resistors Philadelphia Div (USA) |
| 1000+5K | Vernitron Corp Vrn International Div (USA) |
| X1001003 | S P S Inc (USA) |
| 1000-502J | Trw Inc Trw Electronic Components Irc Fixed Resistors Philadelphia Div (USA) |
| 1000-502J PRIMARY | Trw Inc Trw Intl Trade Government Sales Dept (USA) |
NSN 5905-00-936-8402 is a Resistor,variable,wire Wound,pre, manufactured by Trw Inc Trw Intl Trade Government Sales Dept, classified under FSC 5905 (No Item Name Available). Status: cancelled.
NSN 5905-00-936-8402 has 5 cross-referenced part numbers: 1000-5000 (Trw Inc Trw Electronic Components Irc Fixed Resistors Philadelphia Div), 1000+5K (Vernitron Corp Vrn International Div), X1001003 (S P S Inc), 1000-502J (Trw Inc Trw Electronic Components Irc Fixed Resistors Philadelphia Div), 1000-502J (Trw Inc Trw Intl Trade Government Sales Dept).
There are 2 known substitutes for 5905-00-936-8402: 5998-00-794-2131, 4720-01-588-1569. Verify interchangeability with system specifications before substitution.
Key specifications for 1000-502J: Actuator Type: SINGLE SHAFT; Overall Length: 2.547 INCHES NOMINAL IN; Rotary Actuator Travel in Angular Deg: 3600.0 MINIMUM; Body Length: 1.344 INCHES NOMINAL IN. 30 total characteristics are documented in the Federal Logistics Information System.
NSN 5905-00-936-8402 is currently cancelled. Check with the Defense Logistics Agency for current availability and authorized substitutes.