The Resistor,thermal, cataloged under National Stock Number 5905-00-912-0327, is classified within Federal Supply Class 5905 (No Item Name Available) of the Electrical and Electronic Equipment Components group. The primary manufacturer of record is Ysi Inc. Government technical data includes 30 verified specifications, sourced from the Federal Logistics Information System (FLIS). This item has 3 commercial cross-references from 3 manufacturers, enabling identification through both NSN and commercial part number lookups. 11 verified substitutes exist in the FLIS interchangeability database. Current acquisition status: Active.
| Parameter | Value |
|---|---|
| NSN | 5905-00-912-0327 |
| Primary Part Number | 44005 |
| Item Name | Resistor,thermal |
| FSC / FSG | 5905 / 59 — No Item Name Available |
| Manufacturer | Ysi Inc |
| Status | ACTIVE |
| Zero Power Resistance at Specified Temp | 833.7 OHMS SIXTH RESISTANCE-TEMPERATURE POINT |
| Zero Power Resistance at Specified Temp | 1.8 KILOHMS FOURTH RESISTANCE-TEMPERATURE POINT |
| Temp Points for Resistance Readings at Zero Power | -40.0 CELSIUS FIRST RESISTANCE-TEMPERATURE POINT DEGC |
| Zero Power Resistance at Specified Temp | 174.5 OHMS TENTH RESISTANCE-TEMPERATURE POINT |
| Maximum Operating Temp | 80.0 CELSIUS DEGC |
| Zero Power Resistance | 1.000 KILOHMS |
| Ambient Temp at Full Rated Power | 25.0 CELSIUS DEGC |
| Power Dissipation Constant in Milliwatts Per Deg Celsius | 1.0 |
| Terminal Diameter | 0.020 INCHES NOMINAL IN |
| Thermal Time Constant in Seconds | 10.0 |
| Terminal Length | 3.000 INCHES NOMINAL IN |
| Body Outside Diameter | 0.095 INCHES MAXIMUM IN |
| Temp Points for Resistance Readings at Zero Power | 0.0 CELSIUS THIRD RESISTANCE-TEMPERATURE POINT DEGC |
| Temp Points for Resistance Readings at Zero Power | 70.0 CELSIUS NINTH RESISTANCE-TEMPERATURE POINT DEGC |
| Temp Points for Resistance Readings at Zero Power | 10.0 CELSIUS FOURTH RESISTANCE-TEMPERATURE POINT DEGC |
| Reference Temp in Deg Celsius | 25.0 |
| Zero Power Resistance at Specified Temp | 2.7 KILOHMS THIRD RESISTANCE-TEMPERATURE POINT |
| Temp Points for Resistance Readings at Zero Power | 20.0 CELSIUS FIFTH RESISTANCE-TEMPERATURE POINT DEGC |
| Resistance Tolerance at a Specified Temp in Percent | -1.0 TO 1.0 SEVENTH RESISTANCE-TEMPERATURE POINT |
| Resistance Tolerance at a Specified Temp in Percent | -1.0 TO 1.0 TENTH RESISTANCE-TEMPERATURE POINT |
| Resistance Tolerance at a Specified Temp in Percent | -1.3 TO 1.3 FOURTH RESISTANCE-TEMPERATURE POINT |
| Zero Power Resistance at Specified Temp | 6.6 KILOHMS SECOND RESISTANCE-TEMPERATURE POINT |
| Resistance Tolerance at a Specified Temp in Percent | -1.4 TO 1.4 THIRD RESISTANCE-TEMPERATURE POINT |
| Zero Power Resistance at Specified Temp | 310.5 OHMS EIGHTH RESISTANCE-TEMPERATURE POINT |
| Terminal Type and Quantity | 2 WIRE LEAD |
| Resistance Tolerance at a Specified Temp in Percent | -1.1 TO 1.1 FIFTH RESISTANCE-TEMPERATURE POINT |
| Zero Power Resistance at Specified Temp | 1.2 KILOHMS FIFTH RESISTANCE-TEMPERATURE POINT |
| Temp Points for Resistance Readings at Zero Power | 80.0 CELSIUS TENTH RESISTANCE-TEMPERATURE POINT DEGC |
| Zero Power Resistance at Specified Temp | 18.6 KILOHMS FIRST RESISTANCE-TEMPERATURE POINT |
| Zero Power Resistance at Specified Temp | 423.9 OHMS SEVENTH RESISTANCE-TEMPERATURE POINT |
| Acquisition Status | ACTIVE |
| HAZMAT | No |
NSN 5905-00-912-0327 is a Resistor,thermal, manufactured by Ysi Inc, classified under FSC 5905 (No Item Name Available). Status: active.
NSN 5905-00-912-0327 has 3 cross-referenced part numbers: 1450090-1 (Caes Systems Llc), 44005 (Ysi Inc), 8437363 (Army, United States Department of the Dba Rock Island Arsenal Jmtc).
There are 11 known substitutes for 5905-00-912-0327: 5940-00-226-9612, 5133-00-227-9647, 4931-00-462-8228 and 8 more. Verify interchangeability with system specifications before substitution.
Key specifications for 44005: Zero Power Resistance at Specified Temp: 833.7 OHMS SIXTH RESISTANCE-TEMPERATURE POINT; Zero Power Resistance at Specified Temp: 1.8 KILOHMS FOURTH RESISTANCE-TEMPERATURE POINT; Temp Points for Resistance Readings at Zero Power: -40.0 CELSIUS FIRST RESISTANCE-TEMPERATURE POINT DEGC; Zero Power Resistance at Specified Temp: 174.5 OHMS TENTH RESISTANCE-TEMPERATURE POINT. 30 total characteristics are documented in the Federal Logistics Information System.