The Resistor,variable,wire Wound,pre, cataloged under National Stock Number 5905-00-503-8676, is classified within Federal Supply Class 5905 (No Item Name Available) of the Electrical and Electronic Equipment Components group. The primary manufacturer of record is Department of Defense Project Manager-Mobile Electric Power. Government technical data includes 30 verified specifications, sourced from the Federal Logistics Information System (FLIS). This item has 6 commercial cross-references from 5 manufacturers, enabling identification through both NSN and commercial part number lookups. 9 verified substitutes exist in the FLIS interchangeability database. Current acquisition status: Cancelled.
| Parameter | Value |
|---|---|
| NSN | 5905-00-503-8676 |
| Primary Part Number | 76-4178 |
| Item Name | Resistor,variable,wire Wound,pre |
| FSC / FSG | 5905 / 59 — No Item Name Available |
| Manufacturer | Department of Defense Project Manager-Mobile Electric Power |
| Status | CANCELLED |
| Rotary Actuator Travel in Angular Deg | 1080.0 NOMINAL |
| Bearing Type | SLEEVE SHAFT |
| Body Style | CYLINDRICAL BUSHING MOUNTED |
| Actuator Type | SINGLE SHAFT |
| Ambient Temp in Deg Celsius Per Section at Zero Percent Rated Power | 85.0 SINGLE SECTION |
| Screw Thread Series Designator | UNEF |
| Shaft Radial Play | 0.004 INCHES IN |
| Mounting Method | STANDARD BUSHING |
| Shaft Runout | 0.0005 INCHES IN |
| Pilot Diameter Runout | 0.00200 INCHES IN |
| Effective Electrical Rotation in Deg Angular Rotation | 1080.0 NOMINAL |
| Screw Thread Quantity Per Inch | 32.0 |
| Maximum Running Torque | 3.00 INCH-OUNCES IN |
| Screw Thread Diameter | 0.375 INCHES NOMINAL IN |
| Maximum Starting Torque | 3.00 INCH-OUNCES IN |
| Function Conformity Tolerance Per Section | -0.50 TO 0.50 SINGLE SECTION |
| Lateral Runout | 0.003 INCHES IN |
| Shaft End Play | 0.00500 INCHES IN |
| Electrical Resistance Per Section | 500.000 OHMS SINGLE SECTION |
| Temp Coefficient of Resistance Wire Per Section in Ppm Per Deg Celsius | -20.0 TO 20.0 SINGLE SECTION |
| Function Conformity Per Section | SINGLE SECTION INDEPENDENT LINEARITY |
| Power Dissipation Rating Per Section in Watts | 3.0 FREE AIR SINGLE SECTION |
| Resistance Tolerance Per Section in Percent | -5.0 TO 5.0 SINGLE SECTION |
| Terminal Location | LONGITUDINALLY POSITIONED ON THE CIRCUMFERENCE LOCATION NOT OTHERWISE SPECIFIED |
| Terminal Type and Quantity | 3 TAB, SOLDER LUG |
| Ambient Temp in Deg Celsius Per Section at Full Rated Power | 40.0 SINGLE SECTION |
| Function Characteristic Per Section | SINGLE SECTION LINEAR |
| Actuator Travel Control Feature | CLUTCH |
| Body Diameter | 1.812 INCHES NOMINAL IN |
| Shaft Length | 0.812 INCHES NOMINAL IN |
| Acquisition Status | CANCELLED |
| HAZMAT | No |
| Part Number | Manufacturer |
|---|---|
| 232010 | Woodward, Inc. (USA) |
| CR500L0.5 | Bi Technologies Corporation Div Bi Technologies Corp. (USA) |
| 9097-073 | Woodward, Inc. (USA) |
| C-500OHMSPORM5PCT | Beckman Research and Mfg Co (USA) |
| 76-4178 PRIMARY | Department of Defense Project Manager-Mobile Electric Power (USA) |
| 23210 | Woodward, Inc. Div Fuel Systems and Controls (USA) |
NSN 5905-00-503-8676 is a Resistor,variable,wire Wound,pre, manufactured by Department of Defense Project Manager-Mobile Electric Power, classified under FSC 5905 (No Item Name Available). Status: cancelled.
NSN 5905-00-503-8676 has 6 cross-referenced part numbers: 232010 (Woodward, Inc.), CR500L0.5 (Bi Technologies Corporation Div Bi Technologies Corp.), 9097-073 (Woodward, Inc.), C-500OHMSPORM5PCT (Beckman Research and Mfg Co), 76-4178 (Department of Defense Project Manager-Mobile Electric Power) and 1 more.
There are 9 known substitutes for 5905-00-503-8676: 9540-00-145-7553, 5315-00-281-7650, 9540-00-827-2214 and 6 more. Verify interchangeability with system specifications before substitution.
Key specifications for 76-4178: Rotary Actuator Travel in Angular Deg: 1080.0 NOMINAL; Bearing Type: SLEEVE SHAFT; Body Style: CYLINDRICAL BUSHING MOUNTED; Actuator Type: SINGLE SHAFT. 30 total characteristics are documented in the Federal Logistics Information System.
NSN 5905-00-503-8676 is currently cancelled. Check with the Defense Logistics Agency for current availability and authorized substitutes.