The Resistor,thermal, cataloged under National Stock Number 5905-00-421-0826, is classified within Federal Supply Class 5905 (Resistor) of the Electrical and Electronic Equipment Components group. Government technical data includes 30 specifications, cited from the U.S. Government catalog. 1 additional reference document (drawings, advisory and superseded references) is recorded in the U.S. Government catalog. Current acquisition status: Active.
| Parameter | Value |
|---|---|
| NSN | 5905-00-421-0826 |
| Item Name | Resistor,thermal |
| FSC / FSG | 5905 / 59 — Resistor |
| Status | ACTIVE |
| Temp Points for Resistance Readings at Zero Power | -10.0 CELSIUS THIRD RESISTANCE-TEMPERATURE POINT DEGC |
| Temp Points for Resistance Readings at Zero Power | -30.0 CELSIUS SECOND RESISTANCE-TEMPERATURE POINT DEGC |
| Temp Points for Resistance Readings at Zero Power | 20.0 CELSIUS FOURTH RESISTANCE-TEMPERATURE POINT DEGC |
| Temp Points for Resistance Readings at Zero Power | -60.0 CELSIUS FIRST RESISTANCE-TEMPERATURE POINT DEGC |
| Temp Points for Resistance Readings at Zero Power | 100.0 CELSIUS SIXTH RESISTANCE-TEMPERATURE POINT DEGC |
| Temp Points for Resistance Readings at Zero Power | 300.0 CELSIUS TENTH RESISTANCE-TEMPERATURE POINT DEGC |
| Temp Points for Resistance Readings at Zero Power | 50.0 CELSIUS FIFTH RESISTANCE-TEMPERATURE POINT DEGC |
| Temp Points for Resistance Readings at Zero Power | 140.0 CELSIUS SEVENTH RESISTANCE-TEMPERATURE POINT DEGC |
| Temp Points for Resistance Readings at Zero Power | 200.0 CELSIUS EIGHTH RESISTANCE-TEMPERATURE POINT DEGC |
| Temp Points for Resistance Readings at Zero Power | 260.0 CELSIUS NINTH RESISTANCE-TEMPERATURE POINT DEGC |
| Inclosure Type | ENCAPSULATED |
| Terminal Diameter | 0.004 INCHES NOMINAL IN |
| Resistance Tolerance at a Specified Temp in Percent | -18.4 TO 18.4 NINTH RESISTANCE-TEMPERATURE POINT |
| Resistance Tolerance at a Specified Temp in Percent | -11.3 TO 11.3 SECOND RESISTANCE-TEMPERATURE POINT |
| Resistance Tolerance at a Specified Temp in Percent | -11.3 TO 11.3 SIXTH RESISTANCE-TEMPERATURE POINT |
| Resistance Tolerance at a Specified Temp in Percent | -13.4 TO 13.4 SEVENTH RESISTANCE-TEMPERATURE POINT |
| Resistance Tolerance at a Specified Temp in Percent | -15.9 TO 15.9 FIRST RESISTANCE-TEMPERATURE POINT |
| Resistance Tolerance at a Specified Temp in Percent | -16.4 TO 16.4 EIGHTH RESISTANCE-TEMPERATURE POINT |
| Resistance Tolerance at a Specified Temp in Percent | -19.5 TO 19.5 TENTH RESISTANCE-TEMPERATURE POINT |
| Resistance Tolerance at a Specified Temp in Percent | -5.3 TO 5.3 FOURTH RESISTANCE-TEMPERATURE POINT |
| Resistance Tolerance at a Specified Temp in Percent | -7.5 TO 7.5 FIFTH RESISTANCE-TEMPERATURE POINT |
| Resistance Tolerance at a Specified Temp in Percent | -8.7 TO 8.7 THIRD RESISTANCE-TEMPERATURE POINT |
| Terminal Length | 1.500 INCHES NOMINAL IN |
| Zero Power Resistance at Specified Temp | 11.5 OHMS NINTH RESISTANCE-TEMPERATURE POINT |
| Zero Power Resistance at Specified Temp | 152.2 KILOHMS FIRST RESISTANCE-TEMPERATURE POINT |
| Zero Power Resistance at Specified Temp | 184.7 OHMS SIXTH RESISTANCE-TEMPERATURE POINT |
| Zero Power Resistance at Specified Temp | 2.4 KILOHMS FOURTH RESISTANCE-TEMPERATURE POINT |
| Zero Power Resistance at Specified Temp | 25.0 OHMS EIGHTH RESISTANCE-TEMPERATURE POINT |
| Zero Power Resistance at Specified Temp | 25.2 KILOHMS SECOND RESISTANCE-TEMPERATURE POINT |
| Zero Power Resistance at Specified Temp | 7.7 OHMS TENTH RESISTANCE-TEMPERATURE POINT |
| Acquisition Status | ACTIVE |
| DEMIL Code | DEMIL A — No Demilitarization Required |
| Hazard | No hazard code in the DLA record (HMIC N) |
| Criticality Code | X |
| Reference | Meaning |
|---|---|
| GB32L2 | 3/9 Design control — primary reference Baxter Healthcare Corporation Dba Baxter Biotech Div Transfusion Therapies |
NSN 5905-00-421-0826 is a Resistor,thermal, classified under FSC 5905, Resistor. Status: active.
Key specifications for 5905-00-421-0826: Temp Points for Resistance Readings at Zero Power: -10.0 CELSIUS THIRD RESISTANCE-TEMPERATURE POINT DEGC; Temp Points for Resistance Readings at Zero Power: -30.0 CELSIUS SECOND RESISTANCE-TEMPERATURE POINT DEGC; Temp Points for Resistance Readings at Zero Power: 20.0 CELSIUS FOURTH RESISTANCE-TEMPERATURE POINT DEGC; Temp Points for Resistance Readings at Zero Power: -60.0 CELSIUS FIRST RESISTANCE-TEMPERATURE POINT DEGC. 30 specifications are documented in the U.S. Government catalog.
No hazard code in the DLA record (HMIC N). Hazard information on this page is shown exactly as it appears in the DLA record.
U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-16.
U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-18.