The Resistor,variable,wire Wound,non, cataloged under National Stock Number 5905-00-410-1313, is classified within Federal Supply Class 5905 (No Item Name Available) of the Electrical and Electronic Equipment Components group. The primary manufacturer of record is Keysight Technologies Inc. Government technical data includes 22 verified specifications, sourced from the Federal Logistics Information System (FLIS). This item has 9 commercial cross-references from 8 manufacturers, enabling identification through both NSN and commercial part number lookups. 3 verified substitutes exist in the FLIS interchangeability database. Current acquisition status: Cancelled.
| Parameter | Value |
|---|---|
| NSN | 5905-00-410-1313 |
| Primary Part Number | 2100-2031 |
| Item Name | Resistor,variable,wire Wound,non |
| FSC / FSG | 5905 / 59 — No Item Name Available |
| Manufacturer | Keysight Technologies Inc |
| Status | CANCELLED |
| Center to Center Distance Between Terminals | 0.100 INCHES NOMINAL IN |
| Rotary Actuator Travel in Angular Deg | 270.0 NOMINAL |
| Center to Center Distance Between Terminal Rows | 0.100 INCHES NOMINAL IN |
| Center to Center Distance Between Center Terminal and Outside Terminal | 0.100 INCHES NOMINAL IN |
| Power Dissipation Rating Per Section in Watts | 0.5 FREE AIR SINGLE SECTION |
| Mounting Method | TERMINAL |
| Ambient Temp in Deg Celsius Per Section at Full Rated Power | 70.0 SINGLE SECTION |
| Terminal Location | LOWER ADJACENT SIDE TWO ROWS LOCATION NOT OTHERWISE SPECIFIED |
| Resistance Tolerance Per Section in Percent | -10.0 TO 20.0 SINGLE SECTION |
| Temp Coefficient of Resistance Per Section in Ppm Per Deg Celsius | -250.0 TO 250.0 SINGLE SECTION |
| Terminal Type and Quantity | 3 PIN |
| Actuator Travel Control Feature | STOPS |
| Body Length | 0.250 INCHES NOMINAL IN |
| Terminal Length | 0.250 INCHES NOMINAL IN |
| Body Diameter | 0.250 INCHES NOMINAL IN |
| Reliability Indicator | NOT ESTABLISHED |
| Effective Electrical Rotation in Deg Angular Rotation | 220.0 NOMINAL |
| Section Quantity | 1 |
| Body Style | CYLINDRICAL |
| Actuator Type | FLUSH DRIVE WITH SLOT-HOLE |
| Electrical Resistance Per Section | 50.0 KILOHMS SINGLE SECTION |
| Ambient Temp in Deg Celsius Per Section at Zero Percent Rated Power | 125.0 SINGLE SECTION |
| Acquisition Status | CANCELLED |
| HAZMAT | No |
| Part Number | Manufacturer |
|---|---|
| 369-01 | Halear Inc Dba Preston Scientific (USA) |
| 2100-2031 PRIMARY | Keysight Technologies Inc (USA) |
| 50204-5031-95 | Asrc Federal Facilities Logistics, Llc (USA) |
| 5010097-012 | Cohu, Inc. Dba Cohu Electronic's Division Div Electronics Division (USA) |
| 2100-2031 | Keysight Technologies, Inc. (USA) |
| 369A | Halear Inc Dba Preston Scientific (USA) |
| TYPE500-503 | Trw Inc Trw Electronic Components Irc Fixed Resistors Philadelphia Div (USA) |
| 50204-5031-95 | Harsco Corp Bmy-Combat Systems Div (USA) |
| 2100-2031 | Hewlett-Packard Company Dba HP (USA) |
NSN 5905-00-410-1313 is a Resistor,variable,wire Wound,non, manufactured by Keysight Technologies Inc, classified under FSC 5905 (No Item Name Available). Status: cancelled.
NSN 5905-00-410-1313 has 9 cross-referenced part numbers: 369-01 (Halear Inc Dba Preston Scientific), 2100-2031 (Keysight Technologies Inc), 50204-5031-95 (Asrc Federal Facilities Logistics, Llc), 5010097-012 (Cohu, Inc. Dba Cohu Electronic's Division Div Electronics Division), 2100-2031 (Keysight Technologies, Inc.) and 4 more.
There are 3 known substitutes for 5905-00-410-1313: 3110-00-100-0221, 6105-00-635-1362, 5310-01-294-4192. Verify interchangeability with system specifications before substitution.
Key specifications for 2100-2031: Center to Center Distance Between Terminals: 0.100 INCHES NOMINAL IN; Rotary Actuator Travel in Angular Deg: 270.0 NOMINAL; Center to Center Distance Between Terminal Rows: 0.100 INCHES NOMINAL IN; Center to Center Distance Between Center Terminal and Outside Terminal: 0.100 INCHES NOMINAL IN. 22 total characteristics are documented in the Federal Logistics Information System.
NSN 5905-00-410-1313 is currently cancelled. Check with the Defense Logistics Agency for current availability and authorized substitutes.