PartsTable TECHNICAL DATA SHEET
JULY 2026Technical Data Sheet

RV6LAYSA502AResistor,variable,nonwire Wound,

Cts Corp Electromechanical Div · NSN 5905-00-244-9307 · FSC 5905 · No Item Name Available
Verified by PartsTable
NSN 5905-00-244-9307 — this item is cataloged by the U.S. Government under National Stock Number 5905-00-244-9307. Primary manufacturer part number: RV6LAYSA502A.
Features
  • Resistor,variable,nonwire Wound, — FSC 5905
  • Shaft Length: 0.594 INCHES MINIMUM AND 0.656 INCHES MAXIMUM IN
  • Body Diameter: 0.484 INCHES MINIMUM AND 0.516 INCHES MAXIMUM IN
  • Maximum Stop Torque: 48.00 INCH-OUNCES IN
  • Terminal Type and Quantity: 3 TAB, SOLDER LUG
  • Resistance Tolerance Per Section in Percent: -10.0 TO 10.0 SINGLE SECTION
  • Terminal Location: REAR END
  • Ambient Temp in Deg Celsius Per Section at Full Rated Power: 70.0 SINGLE SECTION
Applications
  • Circuit regulation and filtering
  • Signal conditioning
  • Power supply stabilization
General Description

The Resistor,variable,nonwire Wound,, cataloged under National Stock Number 5905-00-244-9307, is classified within Federal Supply Class 5905 (No Item Name Available) of the Electrical and Electronic Equipment Components group. The primary manufacturer of record is Cts Corp Electromechanical Div. Government technical data includes 29 verified specifications, sourced from the Federal Logistics Information System (FLIS). This item has 4 commercial cross-references from 4 manufacturers, enabling identification through both NSN and commercial part number lookups. 3 verified substitutes exist in the FLIS interchangeability database. Current acquisition status: Active.

Technical Specifications
ParameterValue
NSN5905-00-244-9307
Primary Part NumberRV6LAYSA502A
Item NameResistor,variable,nonwire Wound,
FSC / FSG5905 / 59 — No Item Name Available
ManufacturerCts Corp Electromechanical Div
StatusACTIVE
Shaft Length0.594 INCHES MINIMUM AND 0.656 INCHES MAXIMUM IN
Body Diameter0.484 INCHES MINIMUM AND 0.516 INCHES MAXIMUM IN
Maximum Stop Torque48.00 INCH-OUNCES IN
Terminal Type and Quantity3 TAB, SOLDER LUG
Resistance Tolerance Per Section in Percent-10.0 TO 10.0 SINGLE SECTION
Terminal LocationREAR END
Ambient Temp in Deg Celsius Per Section at Full Rated Power70.0 SINGLE SECTION
Actuator Travel Control FeatureSTOPS
Reference Number Differentiating CharacteristicsMATERIAL WILL BE IN ACCORDANCE WITH SHIPS PARTS CONTROL CENTER ACTIVITY HX QUALITY CONTROL,MANUFACTURING AND TESTING SPECIFICATIONS
Power Dissipation Rating Per Section in Watts0.5 FREE AIR SINGLE SECTION
Device Design TypeERR-030 AT 5:00 OCLOCKUNABLE TO DECODE
Screw Thread Quantity Per Inch32.0
Device Design TypeERR-030 AT 10:00 OCLOCKUNABLE TO DECODE
Ambient Temp in Deg Celsius Per Section at Zero Percent Rated Power120.0 SINGLE SECTION
Nonturn Device Radius0.240 INCHES MINIMUM AND 0.250 INCHES MAXIMUM IN
Screw Thread Diameter0.250 INCHES NOMINAL IN
Electrical Resistance Per Section5.000 KILOHMS SINGLE SECTION
Screw Thread Series DesignatorUNEF
Mounting MethodLOCKING BUSHING
Rotary Actuator Travel in Angular Deg292.0 MINIMUM AND 298.0 MAXIMUM
Body Length0.500 INCHES NOMINAL IN
Overall Diameter0.484 INCHES MINIMUM AND 0.516 INCHES MAXIMUM IN
Actuator TypeSINGLE SHAFT
Shaft Diameter0.124 INCHES MINIMUM AND 0.126 INCHES MAXIMUM IN
Mounting Bushing Length0.484 INCHES MINIMUM AND 0.516 INCHES MAXIMUM IN
Shaft StyleROUND, SLOTTED
Maximum Starting Torque6.00 INCH-OUNCES IN
Section Quantity1
Body StyleCYLINDRICAL BUSHING MOUNTED
Lifecycle & Compliance
Acquisition StatusACTIVE
HAZMATNo
Verified Substitutes 3
5905-00-577-0435 INTERCHANGEABLE
Resistor,variable,nonwire Wound,
5905-00-799-8566 INTERCHANGEABLE
Resistor,variable,nonwire Wound,
5905-01-393-5029 INTERCHANGEABLE
Resistor,variable,nonwire Wound,
Cross-Reference Index
Part NumberManufacturer
RV6LAYSA502A Cts Corp Electromechanical Div (USA)
942J091PC137 Northrop Grumman Systems Corporation Div Marine Systems (USA)
RV6LAYSA502A V1A Fmc Technologies Inc Dba Fmc Fluid Control (USA)
RV6LAYSA502A Cts Corp (USA)
Related Parts
5905-00-577-0435INTERCHANGEABLE
RESISTOR,VARIABLE,NONWIRE WOUND,
5905-00-799-8566INTERCHANGEABLE
RESISTOR,VARIABLE,NONWIRE WOUND,
5905-01-393-5029INTERCHANGEABLE
RESISTOR,VARIABLE,NONWIRE WOUND,

Frequently Asked Questions

What is NSN 5905-00-244-9307?

NSN 5905-00-244-9307 is a Resistor,variable,nonwire Wound,, manufactured by Cts Corp Electromechanical Div, classified under FSC 5905 (No Item Name Available). Status: active.

What are the part numbers for NSN 5905-00-244-9307?

NSN 5905-00-244-9307 has 4 cross-referenced part numbers: RV6LAYSA502A (Cts Corp Electromechanical Div), 942J091PC137 (Northrop Grumman Systems Corporation Div Marine Systems), RV6LAYSA502A V1A (Fmc Technologies Inc Dba Fmc Fluid Control), RV6LAYSA502A (Cts Corp).

What NSN replaces 5905-00-244-9307?

There are 3 known substitutes for 5905-00-244-9307: 5905-00-577-0435, 5905-00-799-8566, 5905-01-393-5029. Verify interchangeability with system specifications before substitution.

What are the specifications of RV6LAYSA502A?

Key specifications for RV6LAYSA502A: Shaft Length: 0.594 INCHES MINIMUM AND 0.656 INCHES MAXIMUM IN; Body Diameter: 0.484 INCHES MINIMUM AND 0.516 INCHES MAXIMUM IN; Maximum Stop Torque: 48.00 INCH-OUNCES IN; Terminal Type and Quantity: 3 TAB, SOLDER LUG. 29 total characteristics are documented in the Federal Logistics Information System.

Validated with multiple authoritative sources, including Government, OEM, and Certified sources.
PartsTable Design LLC · partstable.com