PartsTable
Technical Data Sheet
Download PDF

58C6226 — GENERATOR,DIRECT CURRENT

✓ Government record, cited
AIR FORCE STANDARD · MOTOR
PRODUCT OVERVIEW

58C6226: GENERATOR,DIRECT CURRENT.

The GENERATOR,DIRECT CURRENT is a AIR FORCE STANDARD industrial component. Key specifications include EXCITOR TYPE: SELF-EXCITED, POWER RATING: 9.000 KILOWATTS INPUT, WINDING TYPE: SHUNT WOUND, MAXIMUM OPERATING ALTITUDE RATING: 20000.0 FEET FT, MOUNTING FACILITY TYPE AND QUANTITY: 6 UNTHREADED HOLE(S), CONNECTION TYPE AND VOLTAGE RATING IN VOLTS: 30.0 LINE TO NEUTRAL SINGLE OUTPUT. This part is cataloged in the U.S.

Government catalog under NSN 6115-00-725-1790, indicating validated use in U.S. government and defense logistics supply chains. Available through authorized enterprise resellers and TPM (Third Party Maintenance) channels.

Verify compatibility with your specific system configuration before ordering.

WHERE IT FITS
58C6226
NSN: 6115-00-725-1790
FSC: 6115 — Generators and Generator Sets, Electrical
CAGE: 99238 — AIR FORCE STANDARD
SPECIFICATIONS
EXCITOR TYPESELF-EXCITED
POWER RATING9.000 KILOWATTS INPUT
WINDING TYPESHUNT WOUND
MAXIMUM OPERATING ALTITUDE RATING20000.0 FEET FT
MOUNTING FACILITY TYPE AND QUANTITY6 UNTHREADED HOLE(S)
CONNECTION TYPE AND VOLTAGE RATING IN VOLTS30.0 LINE TO NEUTRAL SINGLE OUTPUT
NSN6115-00-725-1790
COMPONENT DIAGRAM
ELECTRIC MOTOR — FRAME SIZE = MOUNTING PATTERN SHAFT J-BOX MOUNTING FEET — FRAME — — · — RPM — · — PN: 58C6226 · AIR FORCE STANDARD ⚠ VERIFY BEFORE ORDERING NEMA frame size determines mounting bolt pattern — not interchangeable. 56C ≠ 143T bolt pattern. C-face vs foot-mount vs flange — different mounting, same HP doesn't mean drop-in ✓ BROKER TIP TEFC = outdoor/washdown OK. ODP = dry indoor only. TENV = no external fan, explosion-proof areas. 1750 RPM = 4-pole (most common), 3450 RPM = 2-pole, 1150 RPM = 6-pole PARTSTABLE TECHNICAL DRAWING — NOT TO SCALE
KEY FEATURES
•
MOUNTING FACILITY TYPE AND QUANTITY: 6 UNTHREADED HOLE(S)
•
DUTY CYCLE: CONTINUOUS
•
WINDING TYPE: SHUNT WOUND
•
MAXIMUM OPERATING ALTITUDE RATING: 20000.0 FEET FT
•
CONNECTION TYPE AND VOLTAGE RATING IN VOLTS: 30.0 LINE TO NEUTRAL SINGLE OUTPUT
•
POWER RATING: 9.000 KILOWATTS INPUT
•
EXCITOR TYPE: SELF-EXCITED
TECHNICAL CHARACTERISTICS
MOUNTING FACILITY TYPE AND QUANTITY6 UNTHREADED HOLE(S)
DUTY CYCLECONTINUOUS
WINDING TYPESHUNT WOUND
MAXIMUM OPERATING ALTITUDE RATING20000.0 FEET FT
CONNECTION TYPE AND VOLTAGE RATING IN VOLTS30.0 LINE TO NEUTRAL SINGLE OUTPUT
POWER RATING9.000 KILOWATTS INPUT
POWER RATING9.000 KILOWATTS OUTPUT
EXCITOR TYPESELF-EXCITED
SUBSTITUTES & CROSS-REFERENCES 4
30010-000Reference document
Same NSN cross-reference
Reference document — Advisory reference — outside the item-of-supply concept
905D956-2Same NSN cross-reference
Same NSN cross-reference
Also cataloged under this NSN
MIL-G-6162Reference document
Same NSN cross-reference
Reference document — Identification reference
GEU5ASame NSN cross-reference
Same NSN cross-reference
Also cataloged under this NSN
LIFECYCLE
NSN statusCancelled· U.S. Government catalog
Demilitarization required — critical (Q)
Ready to buy 58C6226?
Compare prices from verified sellers on eBay
Buy on eBay →
As an eBay Partner, PartsTable may earn a commission. Your price is not affected.
FREQUENTLY ASKED QUESTIONS
What is 58C6226?
58C6226 is a GENERATOR,DIRECT CURRENT manufactured by AIR FORCE STANDARD.
What parts can replace 58C6226?
There are 4 known substitutes for 58C6226: 30010-000, 905D956-2, MIL-G-6162 and 1 more. Substitute compatibility should be verified for your specific system.
What is the NSN for 58C6226?
58C6226 is cataloged in the U.S. Government catalog under NSN 6115-00-725-1790. This indicates validated use in U.S. government and defense supply chains.
Community Feedback
Leave a Comment
Comments are reviewed before appearing. You will receive an email to verify before your comment appears.

Request a Quote — 58C6226