The Detector,radio Frequency, cataloged under National Stock Number 5895-01-096-2733, is classified within Federal Supply Class 5895 (Miscellaneous Communication Equipment) of the Communication, Detection, and Coherent Radiation Equipment group. The manufacturer of record is Agilent Technologies, Inc. Div Agilent Laboratory. Government technical data includes 12 specifications, cited from the U.S. Government catalog. The record lists 1 manufacturer part number for this item, enabling identification through both NSN and commercial part number lookups. 4 additional reference documents (drawings, advisory and superseded references) are recorded in the U.S. Government catalog. Current acquisition status: Active. Unit of issue: EA.
| Parameter | Value |
|---|---|
| NSN | 5895-01-096-2733 |
| Primary Part Number | 33330C |
| Item Name | Detector,radio Frequency |
| FSC / FSG | 5895 / 58 — Miscellaneous Communication Equipment |
| Manufacturer | Agilent Technologies, Inc. Div Agilent Laboratory |
| Status | ACTIVE |
| Circuit Construction Type | SOLID STATE |
| Inclosure Type | ENCAPSULATED |
| Overall Diameter | 0.380 INCHES NOMINAL IN |
| Average Power Rating Per Channel | 200.0 MILLIWATTS INPUT |
| Frequency Per Channel | 0.01 GIGAHERTZ MINIMUM OPERATING CHANNEL AND 26.50 GIGAHERTZ MAXIMUM OPERATING CHANNEL |
| Connection Contact Type and Quantity | 2 RECEPTACLE, COAXIAL EXTERNAL |
| Operating Control Method | AUTOMATIC |
| Basic Shape Style | CYLINDRICAL |
| Storage Temp Range | -65.0 TO 125.0 CELSIUS DEGC |
| Average Life Measurement | NOT RATED |
| Operating Temp Range | -55.0 TO 100.0 CELSIUS DEGC |
| Installation Design | MODULE |
| Acquisition Status | ACTIVE |
| DEMIL Code | DEMIL D — Destroy Item |
| Hazard | No hazard code in the DLA record (HMIC N) |
| Shelf Life Code | 0 |
| Criticality Code | X |
| Unit of Issue | EA |
| Acquisition advice code | ZZ |
| Weight | 0.6500 lbs |
| Cube | 0.1446 cu ft |
| Part Number | Manufacturer |
|---|---|
| 33330C PRIMARY | Agilent Technologies, Inc. Div Agilent Laboratory (USA) |
| Reference | Meaning |
|---|---|
| HP33330C | 5/9 Secondary reference Hewlett-Packard Co H P Laboratories |
| 33330C | 5/9 Secondary reference Hewlett-Packard Co H P Laboratories |
| MDC95059-3.5 | 5/9 Secondary reference Dal-Tech Devices, Inc. Dba Dal-Tech Devices Inc Div Dal-Tec Devices, Inc |
| 6010204-005 | 7/2 Vendor item drawing reference Bae Systems Information and Electronic Systems Integration Inc. Div Bae Systems Information & Electronic Systems Integration Inc |
NSN 5895-01-096-2733 is a Detector,radio Frequency, manufactured by Agilent Technologies, Inc. Div Agilent Laboratory, classified under FSC 5895, Miscellaneous Communication Equipment. Status: active.
NSN 5895-01-096-2733 has 1 manufacturer part number on file: 33330C (Agilent Technologies, Inc. Div Agilent Laboratory).
Key specifications for 33330C: Circuit Construction Type: SOLID STATE; Inclosure Type: ENCAPSULATED; Overall Diameter: 0.380 INCHES NOMINAL IN; Average Power Rating Per Channel: 200.0 MILLIWATTS INPUT. 12 specifications are documented in the U.S. Government catalog.
No hazard code in the DLA record (HMIC N). Hazard information on this page is shown exactly as it appears in the DLA record.
NSN 5895-01-096-2733 has DEMIL Code D. Demilitarization may be required before disposal or transfer to non-military entities.
U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-16.
U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-18.