- Blower with brush for cleaning sensors, mirrors, lenses and eyepieces<br>- Optimum, non-polluting blowing effect by valve system<br>- With brush for removing dust and other particles<br>- With protective flap This part is cataloged in the Federal Logistics Information System (FLIS) under NSN 6625-01-217-7624, indicating validated use in U.S. government and defense logistics supply chains. Available through authorized enterprise resellers and TPM (Third Party Maintenance) channels.
Verify compatibility with your specific system configuration before ordering.
| material | STEEL |
| part_name_assigned_by_controlling_agency | ECONOMY PLYO BOX SET |
| NSN | 6625-01-217-7624 |
| GENERAL CHARACTERISTICS ITEM DESCRIPTION | BATTERY OPERATED; PORTABLE; SOLID STATE; IN PROTECTIVE CASE; SELF CONTAINED; PRODUCES SIMULATED PHYSIOLOGICAL PARAMETERS FOR BLOOD PRESSURE; ECG WAVEFORMS; RESPIRATION; AND ELECTRONIC TEMP; OPERATES ON COMMON TYPE BATTERY (NOT SUPPLIED); INCLUDES LOW VOLTAGE INDICATOR AND ELECTRODE LEAD CONTINUITY |
| EXTERIOR CONTAINER WEIGHT | 24.00 POUNDS LBS |
| PART NAME ASSIGNED BY CONTROLLING AGENCY | SIMULATOR MEDICAL FUNCTIONS: BATTERY OP PORT SELF-CONTAINED |
| UNIT OF ISSUE CUBE | 0.1200 CUBIC FEET |
| SPECIAL FEATURES | ITEM SHALL PERFORM WITHING FOLLOWING CLIMATIC CONDITIONS: TEMPERATURE, NON-OPERATING, -46 DEG C TO +70 DEG C/OPERATING, 0 DEG C TO 55 DEG C; OPERATING CHARACTERISTICS SHALL BE AS FOLLOWS: BLOOD PRESSURE HEART RATE SHALL BE 30-240 BPM, BP OUTPUTS SHALL BE 0-200 MM HG +/- 2%, UNIT HAVE SELECTABLE 120/80 HG +/- OUTPUT, STATIC AND DYNAMIC WAVE FORMS, ECG SIMULATOR SHALL BE VARIABLE, RESPIRATION RATE BE VARIABLE, TEMPERATURE OUTPUT BE SELECTABLE; UNIT HAVE ELECTRODE LEAD CONTINUITY TEST FEATURE; SELECTOR SWITCH(S)/TERMINALS DESCRIBE FUNCTION, RANGE, TEST; UNIT FURNISHED WITH PROTECTIVE CASE MM |
| GENERAL CHARACTERISTICS ITEM DESCRIPTION | BATTERY OPERATED; PORTABLE; SOLID STATE; IN PROTECTIVE CASE; SELF CONTAINED; PRODUCES SIMULATED PHYSIOLOGICAL PARAMETERS FOR BLOOD PRESSURE; ECG WAVEFORMS; RESPIRATION; AND ELECTRONIC TEMP; OPERATES ON COMMON TYPE BATTERY (NOT SUPPLIED); INCLUDES LOW VOLTAGE INDICATOR AND ELECTRODE LEAD CONTINUITY |
| EXTERIOR CONTAINER WEIGHT | 24.00 POUNDS LBS |
| PART NAME ASSIGNED BY CONTROLLING AGENCY | SIMULATOR MEDICAL FUNCTIONS: BATTERY OP PORT SELF-CONTAINED |
| UNIT OF ISSUE CUBE | 0.1200 CUBIC FEET |
| SPECIAL FEATURES | ITEM SHALL PERFORM WITHING FOLLOWING CLIMATIC CONDITIONS: TEMPERATURE, NON-OPERATING, -46 DEG C TO +70 DEG C/OPERATING, 0 DEG C TO 55 DEG C; OPERATING CHARACTERISTICS SHALL BE AS FOLLOWS: BLOOD PRESSURE HEART RATE SHALL BE 30-240 BPM, BP OUTPUTS SHALL BE 0-200 MM HG +/- 2%, UNIT HAVE SELECTABLE 120/80 HG +/- OUTPUT, STATIC AND DYNAMIC WAVE FORMS, ECG SIMULATOR SHALL BE VARIABLE, RESPIRATION RATE BE VARIABLE, TEMPERATURE OUTPUT BE SELECTABLE; UNIT HAVE ELECTRODE LEAD CONTINUITY TEST FEATURE; SELECTOR SWITCH(S)/TERMINALS DESCRIBE FUNCTION, RANGE, TEST; UNIT FURNISHED WITH PROTECTIVE CASE MM |