PartsTable
Technical Data Sheet
513 593-0 ✓ Verified by PartsTable
· MRO · MRO_GENERAL
WHAT YOU NEED TO KNOW
Stranded for flexible routing, solid for conduit THHN/THWN dual-rated — check both tables
Ampacity depends on installation method
PRODUCT OVERVIEW

The 513 593-0 is a the manufacturer industrial component. Key specifications include color: BLACK FIRST POSITION COVER SINGLE CONDUCTOR, material: COPPER ALLOY 101 OR COPPER ALLOY 102 CORE CONDUCTOR SINGLE CONDUCTOR, temp_rating: 150.0 CELSIUS DEGC, conductor_form: STRANDED SINGLE CONDUCTOR, voltage_rating: 600.0 MAXIMUM ROOT MEAN SQUARE (RMS) OPERATING VOLTAGE SINGLE CONDUCTOR, surface_treatment: TIN CORE CONDUCTOR SINGLE CONDUCTOR. This part is cataloged in the Federal Logistics Information System (FLIS) under NSN 6145-00-003-4174, indicating validated use in U.S.

government and defense logistics supply chains. Available through authorized enterprise resellers and TPM (Third Party Maintenance) channels. Verify compatibility with your specific system configuration before ordering.

WHERE IT FITS
MRO MRO_GENERAL 513 593-0
NSN: 6145-00-003-4174
FSC: 6145
CAGE: S3708 — HUBER AND SUHNER LTD (CHE)
SPECIFICATIONS
colorBLACK FIRST POSITION COVER SINGLE CONDUCTOR
materialCOPPER ALLOY 101 OR COPPER ALLOY 102 CORE CONDUCTOR SINGLE CONDUCTOR
temp_rating150.0 CELSIUS DEGC
conductor_formSTRANDED SINGLE CONDUCTOR
voltage_rating600.0 MAXIMUM ROOT MEAN SQUARE (RMS) OPERATING VOLTAGE SINGLE CONDUCTOR
surface_treatmentTIN CORE CONDUCTOR SINGLE CONDUCTOR
round_conductor_size28 AWG SINGLE CONDUCTOR
cross-sectional_shape_styleROUND
strand_awg_size_per_conductor36 SINGLE CONDUCTOR
strand_quantity_per_conductor7 SINGLE CONDUCTOR
cross_section_outside_diameter0.030 INCHES NOMINAL IN
material_document_and_classificationASTM B33 ASSN STD ALL MATERIAL RESPONSES CORE CONDUCTOR SINGLE CONDUCTOR
NSN6145-00-003-4174
COMPONENT DIAGRAM
WIRE / CABLE — AMPACITY DEPENDS ON INSTALLATION CROSS-SECTION JACKET WIRE SPECIFICATIONS Conductor Size: — Conductor Count: — Voltage Rating: — Insulation: — Temp Rating: — PN: 513 593-0 · OEM ⚠ VERIFY BEFORE ORDERING Ampacity depends on installation method — conduit ≠ free air ≠ underground. Same wire, different ratings. AWG sizing is inverse — smaller number = thicker wire (4 AWG > 12 AWG) ✓ BROKER TIP Stranded = flexible routing and vibration resistance. Solid = fixed conduit runs only. THHN/THWN = dual rated — check both dry and wet ampacity tables PARTSTABLE TECHNICAL DRAWING — NOT TO SCALE
KEY FEATURES
MATERIAL: COPPER ALLOY 101 OR COPPER ALLOY 102 CORE CONDUCTOR SINGLE CONDUCTOR
COLOR: BLACK FIRST POSITION COVER SINGLE CONDUCTOR
SURFACE TREATMENT DOCUMENT AND CLASSIFICATION: ASTM B33-63 ASSN STD SINGLE TREATMENT RESPONSE CORE CONDUCTOR SINGLE CONDUCTOR
CONDUCTOR FORM: STRANDED SINGLE CONDUCTOR
MATERIAL DOCUMENT AND CLASSIFICATION: ASTM B33 ASSN STD ALL MATERIAL RESPONSES CORE CONDUCTOR SINGLE CONDUCTOR
STRAND QUANTITY PER CONDUCTOR: 7 SINGLE CONDUCTOR
TECHNICAL CHARACTERISTICS (FLIS)
MATERIALCOPPER ALLOY 101 OR COPPER ALLOY 102 CORE CONDUCTOR SINGLE CONDUCTOR
COLORBLACK FIRST POSITION COVER SINGLE CONDUCTOR
SURFACE TREATMENT DOCUMENT AND CLASSIFICATIONASTM B33-63 ASSN STD SINGLE TREATMENT RESPONSE CORE CONDUCTOR SINGLE CONDUCTOR
MATERIALPLASTIC POLYALKENE FIRST POSITION PRIMARY INSULATION SINGLE CONDUCTOR
MATERIALPLASTIC POLYVINYLIDENE FLUORIDE SECOND POSITION JACKET SINGLE CONDUCTOR
CONDUCTOR FORMSTRANDED SINGLE CONDUCTOR
MATERIAL DOCUMENT AND CLASSIFICATIONASTM B33 ASSN STD ALL MATERIAL RESPONSES CORE CONDUCTOR SINGLE CONDUCTOR
STRAND QUANTITY PER CONDUCTOR7 SINGLE CONDUCTOR
SURFACE TREATMENTTIN CORE CONDUCTOR SINGLE CONDUCTOR
VOLTAGE RATING600.0 MAXIMUM ROOT MEAN SQUARE (RMS) OPERATING VOLTAGE SINGLE CONDUCTOR
VERIFIED SUBSTITUTES & CROSS-REFERENCES 30
9MIL-W-81044/4Upgraded Successor
successor cross-reference
successor
SAE-AS81044/12Upgraded Successor
successor cross-reference
successor
9M81044/4-24-925Upgraded Successor
successor cross-reference
successor
513 603-926Upgraded Successor
successor cross-reference
successor
44A0111-24-926Upgraded Successor
successor cross-reference
successor
M81044/12-24-926Upgraded Successor
successor cross-reference
successor
LIFECYCLE
StatusCANCELLED
Availability
RoHS CompliantEAR99Not HAZMAT
Ready to buy 513 593-0?
Compare prices from verified sellers on eBay
Buy on eBay →
As an eBay Partner, PartsTable may earn a commission. Your price is not affected.
FREQUENTLY ASKED QUESTIONS
What is 513 593-0?
513 593-0 is a 513 593-0. It is classified as a MRO (MRO_GENERAL).
What parts can replace 513 593-0?
There are 30 known substitutes for 513 593-0: 9MIL-W-81044/4, SAE-AS81044/12, 9M81044/4-24-925 and 27 more. Substitute compatibility should be verified for your specific system.
Is 513 593-0 still available?
513 593-0 is currently cancelled.
Community Feedback
Comments (0)
No comments yet. Be the first to share what you know.
Leave a Comment
Comments are reviewed before appearing. You will receive an email to verify before your comment appears.

Request a Quote — 513 593-0