PartsTable
Technical Data Sheet
5051-1 ✓ Verified by PartsTable
Sandberg · MRO · MRO_GENERAL
WHAT YOU NEED TO KNOW
Stranded for flexible routing, solid for conduit THHN/THWN dual-rated — check both tables
Ampacity depends on installation method
PRODUCT OVERVIEW

Stereo to mono adapter. The adapter has two female phono jacks to one male phono jack. Key specifications include color: CHROME FOURTH POSITION JACKET CABLE, material: ALUMINUM AND PLASTIC POLYESTER SECOND POSITION SHIELD FOIL ALL GROUPS, temp_rating: 60.0 CELSIUS DEGC, conductor_form: STRANDED ALL CONDUCTORS, surface_treatment: TIN CORE CONDUCTOR ALL CONDUCTORS, conductor_quantity: 16.

This product is currently in active production with full OEM support. This part is cataloged in the Federal Logistics Information System (FLIS) under NSN 6145-01-342-5051, indicating validated use in U.S. government and defense logistics supply chains.

Available through authorized enterprise resellers and TPM (Third Party Maintenance) channels. Verify compatibility with your specific system configuration before ordering.

WHERE IT FITS
MRO MRO_GENERAL 5051-1
NSN: 6145-01-342-5051
FSC: 6145
CAGE: 3J659 — IMS NEW HAMPSHIRE (USA)
SPECIFICATIONS
colorCHROME FOURTH POSITION JACKET CABLE
materialALUMINUM AND PLASTIC POLYESTER SECOND POSITION SHIELD FOIL ALL GROUPS
temp_rating60.0 CELSIUS DEGC
conductor_formSTRANDED ALL CONDUCTORS
group_quantity8
special_featuresSIXTH GROUPING ARRANGEMENT ELEVENTH AND TWELFTH CONDUCTORS THROUGH EIGHTH GROUPING ARRANGEMENT FIFTEENTH AND SIXTEENTH CONDUCTORS
surface_treatmentTIN CORE CONDUCTOR ALL CONDUCTORS
conductor_quantity16
round_conductor_size24 AWG ALL CONDUCTORS
cross-sectional_shape_styleROUND
strand_awg_size_per_conductor32 ALL CONDUCTORS
strand_quantity_per_conductor7 ALL CONDUCTORS
NSN6145-01-342-5051
COMPONENT DIAGRAM
WIRE / CABLE — AMPACITY DEPENDS ON INSTALLATION CROSS-SECTION JACKET WIRE SPECIFICATIONS Conductor Size: — Conductor Count: — Voltage Rating: — Insulation: — Temp Rating: — PN: 5051-1 · Sandberg ⚠ VERIFY BEFORE ORDERING Ampacity depends on installation method — conduit ≠ free air ≠ underground. Same wire, different ratings. AWG sizing is inverse — smaller number = thicker wire (4 AWG > 12 AWG) ✓ BROKER TIP Stranded = flexible routing and vibration resistance. Solid = fixed conduit runs only. THHN/THWN = dual rated — check both dry and wet ampacity tables PARTSTABLE TECHNICAL DRAWING — NOT TO SCALE
KEY FEATURES
CONDUCTOR SEQUENCE WITHIN GROUPS: SEVENTH CONDUCTOR AND EIGHTH CONDUCTOR FOURTH GROUP
COLOR CODING DOCUMENT: 8168-16428 SPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS, BROCHURES,ETC., THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS, INDUSTRY DIRECTORIES, AND SIMILAR TRADE PUBLICATIONS, REFLECTING GENERAL TYPE DATA ON CERTAIN ENVIRONMENTAL AND PERFORMANCE REQUIREMENTS AND TEST CONDITIONS THAT ARE SHOWN AS "TYPICAL", "AVERAGE", "NOMINAL", ETC.).
SURFACE TREATMENT: TIN CORE CONDUCTOR ALL CONDUCTORS
GROUP QUANTITY: 8
MATERIAL: ALUMINUM AND PLASTIC POLYESTER THIRD POSITION SHIELD FOIL CABLE
TYPICAL APPLICATIONS
  • Server Internal Cabling
  • Data Center Cable Infrastructure
  • SAS/SATA Drive Connectivity
TECHNICAL CHARACTERISTICS (FLIS)
CONDUCTOR SEQUENCE WITHIN GROUPSSEVENTH CONDUCTOR AND EIGHTH CONDUCTOR FOURTH GROUP
COLOR CODING DOCUMENT8168-16428 SPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS, BROCHURES,ETC., THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS, INDUSTRY DIRECTORIES, AND SIMILAR TRADE PUBLICATIONS, REFLECTING GENERAL TYPE DATA ON CERTAIN ENVIRONMENTAL AND PERFORMANCE REQUIREMENTS AND TEST CONDITIONS THAT ARE SHOWN AS "TYPICAL", "AVERAGE", "NOMINAL", ETC.).
SURFACE TREATMENTTIN CORE CONDUCTOR ALL CONDUCTORS
GROUP QUANTITY8
SPECIAL FEATURESSIXTH GROUPING ARRANGEMENT ELEVENTH AND TWELFTH CONDUCTORS THROUGH EIGHTH GROUPING ARRANGEMENT FIFTEENTH AND SIXTEENTH CONDUCTORS
MATERIALALUMINUM AND PLASTIC POLYESTER THIRD POSITION SHIELD FOIL CABLE
MATERIALCOPPER CORE CONDUCTOR ALL CONDUCTORS
MATERIALPLASTIC, POLYETHYLENE (PP) FIRST POSITION PRIMARY INSULATION ALL CONDUCTORS
SURFACE TREATMENTTIN THIRD POSITION SHIELD BRAID METALLIC CABLE
CONDUCTOR SEQUENCE WITHIN GROUPSFIFTH CONDUCTOR AND SIXTH CONDUCTOR THIRD GROUP
VERIFIED SUBSTITUTES & CROSS-REFERENCES 22
17-6796-060-100Interchangeable
interchangeable cross-reference
interchangeable
65S27162Interchangeable
interchangeable cross-reference
interchangeable
F224M2Z8Interchangeable
interchangeable cross-reference
interchangeable
816-8Interchangeable
interchangeable cross-reference
interchangeable
6996Interchangeable
interchangeable cross-reference
interchangeable
5051Interchangeable
interchangeable cross-reference
interchangeable
LIFECYCLE
StatusACTIVE
AvailabilityOEM and secondary market
RoHS CompliantEAR99Not HAZMAT
Ready to buy 5051-1?
Compare prices from verified sellers on eBay
Buy on eBay →
As an eBay Partner, PartsTable may earn a commission. Your price is not affected.
FREQUENTLY ASKED QUESTIONS
What is 5051-1?
5051-1 is a CABLE ASSEMBLY,RADIO FREQUENCY manufactured by Sandberg. It is classified as a MRO (MRO_GENERAL).
What parts can replace 5051-1?
There are 22 known substitutes for 5051-1: 17-6796-060-100, 65S27162, F224M2Z8 and 19 more. Substitute compatibility should be verified for your specific system.
What is the NSN for 5051-1?
5051-1 is cataloged in the Federal Logistics Information System (FLIS) under NSN 6145-01-342-5051. This indicates validated use in U.S. government and defense supply chains.
Community Feedback
Comments (0)
No comments yet. Be the first to share what you know.
Leave a Comment
Comments are reviewed before appearing. You will receive an email to verify before your comment appears.

Request a Quote — 5051-1