The Test Stand,aircraft Generator, cataloged under National Stock Number 4920-00-278-2279, is classified within Federal Supply Class 4920 (Aircraft Maintenance and Repair Shop Specialized Equipment) of the Maintenance and Repair Shop Equipment group. Government technical data includes 19 specifications, cited from the U.S. Government catalog. 1 additional reference document (drawings, advisory and superseded references) is recorded in the U.S. Government catalog. Current acquisition status: Active.
| Parameter | Value |
|---|---|
| NSN | 4920-00-278-2279 |
| Item Name | Test Stand,aircraft Generator |
| FSC / FSG | 4920 / 49 — Aircraft Maintenance and Repair Shop Specialized Equipment |
| Status | ACTIVE |
| Speed Test Range in RPM | +2000.0 TO 11600.0 |
| Maximum Generator Output in Amps Accommodated | 600.0 |
| Maximum Generator Diameter Accommodated | 11.000 INCHES IN |
| Phase | THREE |
| Blower Unit Motor Current Type | AC |
| Frequency in Hertz | 60.0 |
| Generator Voltage Range in Volts and Current Type Accommodated | +0.0 TO 30.0 AC |
| Current Type | AC |
| Drive Type | SINGLE HEAD |
| Electric Motor Blower | INCLUDED |
| Horsepower Rating | 25.0 |
| Blower Motor Voltage in Volts | 220.0 MINIMUM AND 440.0 MAXIMUM |
| Power Source | ELECTRIC MOTOR |
| Driving Motor Transmission | NOT INCLUDED |
| Voltage in Volts | 220.0 AND 440.0 |
| Blower Motor Frequency in Hertz | 60.0 NOMINAL |
| Nondefinitive Spec/std Data | A-3 TYPE |
| Blower Motor Phase | THREE |
| Mounting Type | FLOOR |
| Acquisition Status | ACTIVE |
| DEMIL Code | DEMIL A — No Demilitarization Required |
| Hazard | No hazard code in the DLA record (HMIC N) |
| Criticality Code | X |
| Reference | Meaning |
|---|---|
| T7223TYPEA3 | 2/2 Government specification standardization U.S. Government activity |
NSN 4920-00-278-2279 is a Test Stand,aircraft Generator, classified under FSC 4920, Aircraft Maintenance and Repair Shop Specialized Equipment. Status: active.
Key specifications for 4920-00-278-2279: Speed Test Range in RPM: +2000.0 TO 11600.0; Maximum Generator Output in Amps Accommodated: 600.0; Maximum Generator Diameter Accommodated: 11.000 INCHES IN; Phase: THREE. 19 specifications are documented in the U.S. Government catalog.
No hazard code in the DLA record (HMIC N). Hazard information on this page is shown exactly as it appears in the DLA record.
U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-16.
U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-18.