The Valve,safety Relief, cataloged under National Stock Number 4820-01-547-2300, is classified within Federal Supply Class 4820 (Valves, Nonpowered) of the Valves group. The manufacturer of record is Sterling Hydraulics Inc. Government technical data includes 10 specifications, cited from the U.S. Government catalog. The record lists 1 manufacturer part number for this item, enabling identification through both NSN and commercial part number lookups. Current acquisition status: Active.
| Parameter | Value |
|---|---|
| NSN | 4820-01-547-2300 |
| Primary Part Number | A04D2HZN |
| Item Name | Valve,safety Relief |
| FSC / FSG | 4820 / 48 — Valves, Nonpowered |
| Manufacturer | Sterling Hydraulics Inc |
| Status | ACTIVE |
| Connection Style | PLAIN (SCREW-IN CARTRIDGE) FIRST END |
| Connection Type | THREADED CARTRIDGE FIRST END |
| Style Designator | SCREW-IN CARTRIDGE |
| Operating Pressure | 3000.0 POUNDS PER SQUARE INCH (PSI) MAXIMUM SINGLE RESPONSE LBS |
| Thread Direction | RIGHT-HAND FIRST END |
| Nominal Thread Size | 0.875 INCHES FIRST END IN |
| Disk Loading Method | SPRING |
| Media for Which Designed | HYDRAULIC FLUID, PETROLEUM BASE SINGLE RESPONSE |
| Thread Series Designator | UNF FIRST END |
| Valve Operation Method | AUTOMATIC |
| Acquisition Status | ACTIVE |
| DEMIL Code | DEMIL A — No Demilitarization Required |
| Hazard | No hazard code in the DLA record (HMIC N) |
| Criticality Code | X |
| Part Number | Manufacturer |
|---|---|
| A04D2HZN PRIMARY | Sterling Hydraulics Inc (USA) |
NSN 4820-01-547-2300 is a Valve,safety Relief, manufactured by Sterling Hydraulics Inc, classified under FSC 4820, Valves, Nonpowered. Status: active.
NSN 4820-01-547-2300 has 1 manufacturer part number on file: A04D2HZN (Sterling Hydraulics Inc).
Key specifications for A04D2HZN: Connection Style: PLAIN (SCREW-IN CARTRIDGE) FIRST END; Connection Type: THREADED CARTRIDGE FIRST END; Style Designator: SCREW-IN CARTRIDGE; Operating Pressure: 3000.0 POUNDS PER SQUARE INCH (PSI) MAXIMUM SINGLE RESPONSE LBS. 10 specifications are documented in the U.S. Government catalog.
No hazard code in the DLA record (HMIC N). Hazard information on this page is shown exactly as it appears in the DLA record.
U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-16.