The Valve,gate, cataloged under National Stock Number 4820-01-416-9685, is classified within Federal Supply Class 4820 (Valves, Nonpowered) of the Valves group. Government technical data includes 17 specifications, cited from the U.S. Government catalog. 3 additional reference documents (drawings, advisory and superseded references) are recorded in the U.S. Government catalog. Current acquisition status: Active.
| Parameter | Value |
|---|---|
| NSN | 4820-01-416-9685 |
| Item Name | Valve,gate |
| FSC / FSG | 4820 / 48 — Valves, Nonpowered |
| Status | ACTIVE |
| Furnished Items and Quantity | 1 HANDWHEEL |
| Inlet Relationship with Outlet | IDENTICAL |
| Flange Face Design | PLAIN |
| Operating Pressure and Type | 150.0 POUNDS PER SQUARE INCH (PSI) STEAM MAXIMUM REQUIRED AND 225.0 POUNDS PER SQUARE INCH (PSI) WATER AND OTHER LIQUIDS MAXIMUM REQUIRED LOCATION NOT OTHERWISE SPECIFIED LBS |
| Stem Type | NONRISING |
| Connection Type | FLANGE, ROUND W/HOLES |
| Valve Size | 1.250 INCHES IN |
| Bonnet Type | INSIDE SCREW |
| Bolt Hole Quantity | 4 |
| Flange Diameter | 4.625 INCHES IN |
| Bonnet Attachment Method | THREADED |
| Face to Face Distance | 4.328 INCHES IN |
| Material | COPPER ALLOY 836 DISK |
| Material | COPPER ALLOY 836 STEM |
| Material | COPPER ALLOY 836 BODY |
| Material | COPPER ALLOY 836 SEAT |
| Valve Operation Method | MANUAL |
| Acquisition Status | ACTIVE |
| DEMIL Code | DEMIL A — No Demilitarization Required |
| Hazard | No hazard code in the DLA record (HMIC N) |
| Criticality Code | X |
| Reference | Meaning |
|---|---|
| 205A 1 1/4IN | 3/9 Design control — primary reference Toyo Valve Co. Ltd |
| 205A 1 1/4IN | 5/9 Secondary reference Fuji Trading America Inc |
| 205A 1 1/4IN | 5/9 Secondary reference Fuji Trading (america) Inc. |
NSN 4820-01-416-9685 is a Valve,gate, classified under FSC 4820, Valves, Nonpowered. Status: active.
Key specifications for 4820-01-416-9685: Furnished Items and Quantity: 1 HANDWHEEL; Inlet Relationship with Outlet: IDENTICAL; Flange Face Design: PLAIN; Operating Pressure and Type: 150.0 POUNDS PER SQUARE INCH (PSI) STEAM MAXIMUM REQUIRED AND 225.0 POUNDS PER SQUARE INCH (PSI) WATER AND OTHER LIQUIDS MAXIMUM REQUIRED LOCATION NOT OTHERWISE SPECIFIED LBS. 17 specifications are documented in the U.S. Government catalog.
No hazard code in the DLA record (HMIC N). Hazard information on this page is shown exactly as it appears in the DLA record.
U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-16.
U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-18.