The Valve,linear,directional Control, cataloged under National Stock Number 4810-01-602-9208, is classified within Federal Supply Class 4810 (Valves, Powered) of the Valves group. The manufacturer of record is Eaton Aerospace, Llc Dba Jackson South. Government technical data includes 2 specifications, cited from the U.S. Government catalog. The record lists 2 manufacturer part numbers for this item, enabling identification through both NSN and commercial part number lookups. Current acquisition status: Active.
| Parameter | Value |
|---|---|
| NSN | 4810-01-602-9208 |
| Primary Part Number | DG4V 0C M U H7 60 |
| Item Name | Valve,linear,directional Control |
| FSC / FSG | 4810 / 48 — Valves, Powered |
| Manufacturer | Eaton Aerospace, Llc Dba Jackson South |
| Status | ACTIVE |
| Voltage in Volts and Current Type | 24.0 DC |
| Valve Operation Method | SOLENOID |
| Acquisition Status | ACTIVE |
| DEMIL Code | DEMIL A — No Demilitarization Required |
| Hazard | No hazard code in the DLA record (HMIC N) |
| Criticality Code | X |
| Part Number | Manufacturer |
|---|---|
| 859162 | Langa Industrial Sa (ESP) |
| DG4V 0C M U H7 60 PRIMARY | Eaton Aerospace, Llc Dba Jackson South (USA) |
NSN 4810-01-602-9208 is a Valve,linear,directional Control, manufactured by Eaton Aerospace, Llc Dba Jackson South, classified under FSC 4810, Valves, Powered. Status: active.
NSN 4810-01-602-9208 has 2 manufacturer part numbers on file: 859162 (Langa Industrial Sa), DG4V 0C M U H7 60 (Eaton Aerospace, Llc Dba Jackson South).
Key specifications for DG4V 0C M U H7 60: Voltage in Volts and Current Type: 24.0 DC; Special Features: AMBIENT TEMPERATURE RANGE IS 20 DEG CELSIUS TO 70 DEG CELSIUS(-4 DEG FAHRENHEIT TO + 158 DEG FAHRENHEIT);TO OBTAIN OPTIMUM SERVICE LIFE FROM BOTH FLUID AND HYDRAULIC SYSTEM, 65 DEG CELSIUS(150 DEG FAHRENHEIT) IS THE RECOMMENDED MAXIMUM FLUID TEMPERATURE, EXCEPT FOR WATER-CONTAINING FLUIDS;ENSURE THAT FLUID VISCOSITIES STAY WITHIN THE LIMITS SPECIFIED IN HYDRAULIC FLUIDS; Part Name Assigned by Controlling Agency: SOLENOID OPERATED DIRECTIONAL VALVE; Valve Operation Method: SOLENOID. 2 specifications are documented in the U.S. Government catalog.
No hazard code in the DLA record (HMIC N). Hazard information on this page is shown exactly as it appears in the DLA record.
U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-16.
U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-18.