The Valve,linear,directional Control, cataloged under National Stock Number 4810-01-445-8969, is classified within Federal Supply Class 4810 (Valves, Powered) of the Valves group. Government technical data includes 15 specifications, cited from the U.S. Government catalog. 1 additional reference document (drawings, advisory and superseded references) is recorded in the U.S. Government catalog. Current acquisition status: Active.
| Parameter | Value |
|---|---|
| NSN | 4810-01-445-8969 |
| Item Name | Valve,linear,directional Control |
| FSC / FSG | 4810 / 48 — Valves, Powered |
| Status | ACTIVE |
| Voltage in Volts and Current Type | 7.6 DC |
| Maximum Operating Temp and Media for Which Designed | 200.0 FAHRENHEIT HYDRAULIC FLUID, PETROLEUM BASE DEGF |
| Operating Pressure and Type | 3000.0 POUNDS PER SQUARE INCH (PSI) HYDRAULIC FLUID, PETROLEUM BASE MAXIMUM REQUIRED LOCATION NOT OTHERWISE SPECIFIED LBS |
| Connection Type | THREADED INTERNAL BOSS |
| End Connection Quantity | 4 |
| Features Provided | MANUAL OVERRIDE |
| Nominal Thread Size | 0.740 INCHES IN |
| Spool Quantity | 3 |
| Body Material | STEEL AND ALUMINUM ALLOY A356.0 |
| Thread Class | 3B |
| Thread Series Designator | UNIFIED NATIONAL JOINT FINE (UNJF) |
| Valve Discharge Flow Rate | 6.0 GALLONS PER MINUTE |
| Valve Operation Method | SOLENOID AND MANUAL |
| Current Rating in Amps | 0.02 |
| Spool Position Quantity | 6 |
| Acquisition Status | ACTIVE |
| DEMIL Code | DEMIL A — No Demilitarization Required |
| Hazard | No hazard code in the DLA record (HMIC N) |
| Criticality Code | X |
| Reference | Meaning |
|---|---|
| 6515-101 | 3/9 Design control — primary reference Accessory Service Inc |
NSN 4810-01-445-8969 is a Valve,linear,directional Control, classified under FSC 4810, Valves, Powered. Status: active.
Key specifications for 4810-01-445-8969: Voltage in Volts and Current Type: 7.6 DC; Maximum Operating Temp and Media for Which Designed: 200.0 FAHRENHEIT HYDRAULIC FLUID, PETROLEUM BASE DEGF; Operating Pressure and Type: 3000.0 POUNDS PER SQUARE INCH (PSI) HYDRAULIC FLUID, PETROLEUM BASE MAXIMUM REQUIRED LOCATION NOT OTHERWISE SPECIFIED LBS; Connection Type: THREADED INTERNAL BOSS. 15 specifications are documented in the U.S. Government catalog.
No hazard code in the DLA record (HMIC N). Hazard information on this page is shown exactly as it appears in the DLA record.
U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-16.
U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-18.