The Valve,linear,directional Control, cataloged under National Stock Number 4810-01-399-7381, is classified within Federal Supply Class 4810 (Valves, Powered) of the Valves group. The manufacturer of record is Danfoss Power Solutions II, Llc. Government technical data includes 4 specifications, cited from the U.S. Government catalog. The record lists 1 manufacturer part number for this item, enabling identification through both NSN and commercial part number lookups. 3 additional reference documents (drawings, advisory and superseded references) are recorded in the U.S. Government catalog. Current acquisition status: Active.
| Parameter | Value |
|---|---|
| NSN | 4810-01-399-7381 |
| Primary Part Number | DG4V3S8CVMFWH561 |
| Item Name | Valve,linear,directional Control |
| FSC / FSG | 4810 / 48 — Valves, Powered |
| Manufacturer | Danfoss Power Solutions II, Llc |
| Status | ACTIVE |
| Voltage in Volts and Current Type | 24.0 DC |
| Operating Pressure and Type | 1450.0 POUNDS PER SQUARE INCH (PSI) STEAM MAXIMUM REQUIRED LOCATION NOT OTHERWISE SPECIFIED LBS |
| End Connection Quantity | 2 |
| Valve Operation Method | SOLENOID |
| Acquisition Status | ACTIVE |
| DEMIL Code | DEMIL A — No Demilitarization Required |
| Hazard | No hazard code in the DLA record (HMIC N) |
| Criticality Code | X |
| Part Number | Manufacturer |
|---|---|
| DG4V3S8CVMFWH561 PRIMARY | Danfoss Power Solutions II, Llc (USA) |
| Reference | Meaning |
|---|---|
| DG4V-3S-8C-VM-FW-HH5-61 | 5/9 Secondary reference Eaton Aerospace, Llc Dba Jackson South |
| DG4V3S8CVMFWH561 | 5/9 Secondary reference Eaton Aerospace, Llc Dba Jackson South |
| DG4V3S8CVMFQH561 | 5/9 Secondary reference Eaton Aerospace, Llc Dba Jackson South |
NSN 4810-01-399-7381 is a Valve,linear,directional Control, manufactured by Danfoss Power Solutions II, Llc, classified under FSC 4810, Valves, Powered. Status: active.
NSN 4810-01-399-7381 has 1 manufacturer part number on file: DG4V3S8CVMFWH561 (Danfoss Power Solutions II, Llc).
Key specifications for DG4V3S8CVMFWH561: Voltage in Volts and Current Type: 24.0 DC; Operating Pressure and Type: 1450.0 POUNDS PER SQUARE INCH (PSI) STEAM MAXIMUM REQUIRED LOCATION NOT OTHERWISE SPECIFIED LBS; End Connection Quantity: 2; Valve Operation Method: SOLENOID. 4 specifications are documented in the U.S. Government catalog.
No hazard code in the DLA record (HMIC N). Hazard information on this page is shown exactly as it appears in the DLA record.
U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-16.