The Valve,solenoid, cataloged under National Stock Number 4810-01-320-1228, is classified within Federal Supply Class 4810 (Valves, Powered) of the Valves group. The manufacturer of record is Parker-Hannifin Corp Div Sporlan Division. Government technical data includes 23 specifications, cited from the U.S. Government catalog. The record lists 1 manufacturer part number for this item, enabling identification through both NSN and commercial part number lookups. 1 additional reference document (drawings, advisory and superseded references) is recorded in the U.S. Government catalog. Current acquisition status: Active.
| Parameter | Value |
|---|---|
| NSN | 4810-01-320-1228 |
| Primary Part Number | B6F1 & MKC1-208/240V |
| Item Name | Valve,solenoid |
| FSC / FSG | 4810 / 48 — Valves, Powered |
| Manufacturer | Parker-Hannifin Corp Div Sporlan Division |
| Status | ACTIVE |
| Flow Control Device | DISK |
| Phase | SINGLE |
| Frequency in Hertz | 10.0 |
| Voltage in Volts and Current Type | 200.0 AC AND 240.0 AC |
| Connection Style | FLARED (TUBE) ALL ENDS |
| Seat Nominal Radius | 37.000 INCHES ALL ENDS IN |
| Mounting Position | HORIZONTAL OR VERTICAL |
| Connection Type | THREADED EXTERNAL TUBE ALL ENDS |
| Style Designator | STRAIGHT THRU |
| Operating Pressure | 500.0 POUNDS PER SQUARE INCH (PSI) MAXIMUM SINGLE RESPONSE LBS |
| Thread Direction | RIGHT-HAND ALL ENDS |
| Nominal Thread Size | 0.375 INCHES ALL ENDS IN |
| Media for Which Designed | REFRIGERANT 22 SECOND RESPONSE |
| Media for Which Designed | REFRIGERANT 12 FIRST RESPONSE |
| Media for Which Designed | REFRIGERANT R-500 THIRD RESPONSE |
| Media for Which Designed | REFRIGERANT R-502 FOURTH RESPONSE |
| Thread Class | 2A ALL ENDS A |
| Thread Quantity Per Inch | 20 ALL ENDS |
| Material | COPPER ALLOY BODY |
| Thread Series Designator | UN ALL ENDS |
| Valve Operation Method | SOLENOID |
| Current Rating in Amps | 0.450 |
| Flow Control Device Normal Operation Position | CLOSED |
| Acquisition Status | ACTIVE |
| DEMIL Code | DEMIL A — No Demilitarization Required |
| Hazard | No hazard code in the DLA record (HMIC N) |
| Criticality Code | X |
| Part Number | Manufacturer |
|---|---|
| B6F1 & MKC1-208/240V PRIMARY | Parker-Hannifin Corp Div Sporlan Division (USA) |
| Reference | Meaning |
|---|---|
| B6F1220V | 5/9 Secondary reference Parker-Hannifin Corp Div Sporlan Division |
NSN 4810-01-320-1228 is a Valve,solenoid, manufactured by Parker-Hannifin Corp Div Sporlan Division, classified under FSC 4810, Valves, Powered. Status: active.
NSN 4810-01-320-1228 has 1 manufacturer part number on file: B6F1 & MKC1-208/240V (Parker-Hannifin Corp Div Sporlan Division).
Key specifications for B6F1 & MKC1-208/240V: Flow Control Device: DISK; Phase: SINGLE; Frequency in Hertz: 10.0; Voltage in Volts and Current Type: 200.0 AC AND 240.0 AC. 23 specifications are documented in the U.S. Government catalog.
No hazard code in the DLA record (HMIC N). Hazard information on this page is shown exactly as it appears in the DLA record.
U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-16.
U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-18.