The Valve,solenoid, cataloged under National Stock Number 4810-00-973-8372, is classified within Federal Supply Class 4810 (Valves, Powered) of the Valves group. Government technical data includes 26 specifications, cited from the U.S. Government catalog. 1 additional reference document (drawings, advisory and superseded references) is recorded in the U.S. Government catalog. Current acquisition status: Active.
| Parameter | Value |
|---|---|
| NSN | 4810-00-973-8372 |
| Item Name | Valve,solenoid |
| FSC / FSG | 4810 / 48 — Valves, Powered |
| Status | ACTIVE |
| Flow Control Device | PISTON |
| Phase | SINGLE |
| Nominal Pipe Size Accommodated | 1.000 INCHES ALL ENDS IN |
| Frequency in Hertz | 50.0 |
| Voltage in Volts and Current Type | 230.0 AC |
| Connection Style | PLAIN,OPTIONAL END(PIPE) ALL ENDS |
| Mounting Position | HORIZONTAL |
| Connection Type | THREADED INTERNAL PIPE ALL ENDS |
| Style Designator | STRAIGHT THRU |
| Operating Pressure | 1500.0 POUNDS PER SQUARE INCH (PSI) MAXIMUM SECOND RESPONSE LBS |
| Operating Pressure | 500.0 POUNDS PER SQUARE INCH (PSI) MAXIMUM FIRST RESPONSE LBS |
| Aperture Diameter | 1.000 INCHES NOMINAL IN |
| Thread Direction | RIGHT-HAND ALL ENDS |
| Nominal Thread Size | 1.000 INCHES ALL ENDS IN |
| Maximum Operating Temp | 250.0 FAHRENHEIT SINGLE RESPONSE DEGF |
| Maximum Operating Temp | 250.0 FAHRENHEIT SECOND RESPONSE DEGF |
| Media for Which Designed | WATER-OIL-GAS SECOND RESPONSE |
| Media for Which Designed | AIR FIRST RESPONSE |
| Thread Quantity Per Inch | 11-1/2 ALL ENDS |
| Material | COPPER ALLOY BODY |
| Material | COPPER ALLOY SEAT |
| Material | STEEL CORROSION RESISTING AND RUBBER SYNTHETIC FLOW CONTROL DEVICE |
| Thread Series Designator | NPT ALL ENDS |
| Valve Operation Method | MANUAL OR SOLENOID |
| Reference Number Differentiating Characteristics | AS DIFFERENTIATED BY VALUE SIZE |
| Flow Control Device Normal Operation Position | CLOSED |
| Acquisition Status | ACTIVE |
| DEMIL Code | DEMIL A — No Demilitarization Required |
| Hazard | No hazard code in the DLA record (HMIC N) |
| Criticality Code | X |
| Reference | Meaning |
|---|---|
| DHP2-4 | 3/1 Design control — primary reference U.S. Government activity |
NSN 4810-00-973-8372 is a Valve,solenoid, classified under FSC 4810, Valves, Powered. Status: active.
Key specifications for 4810-00-973-8372: Flow Control Device: PISTON; Phase: SINGLE; Nominal Pipe Size Accommodated: 1.000 INCHES ALL ENDS IN; Frequency in Hertz: 50.0. 26 specifications are documented in the U.S. Government catalog.
No hazard code in the DLA record (HMIC N). Hazard information on this page is shown exactly as it appears in the DLA record.
U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-16.
U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-18.