The Valve,solenoid, cataloged under National Stock Number 4810-00-134-8949, is classified within Federal Supply Class 4810 (Valves, Powered) of the Valves group. Government technical data includes 19 specifications, cited from the U.S. Government catalog. 2 additional reference documents (drawings, advisory and superseded references) are recorded in the U.S. Government catalog. Current acquisition status: Active.
| Parameter | Value |
|---|---|
| NSN | 4810-00-134-8949 |
| Item Name | Valve,solenoid |
| FSC / FSG | 4810 / 48 — Valves, Powered |
| Status | ACTIVE |
| Flow Control Device | DIAPHRAGM |
| Phase | SINGLE |
| Frequency in Hertz | 50.0 AND 60.0 |
| Voltage in Volts and Current Type | 115.0 AC |
| Connection Style | FLARED (TUBE) ALL ENDS |
| Style Designator | STRAIGHT THRU |
| Operating Pressure | 300.0 POUNDS PER SQUARE INCH (PSI) MAXIMUM SINGLE RESPONSE LBS |
| Thread Direction | RIGHT-HAND ALL ENDS |
| Nominal Thread Size | 0.250 INCHES ALL ENDS IN |
| Seat Angle | 37.0 DEGREES ALL ENDS |
| Maximum Operating Temp | -20.0 FAHRENHEIT FIRST RESPONSE DEGF |
| Maximum Operating Temp | 240.0 FAHRENHEIT SECOND RESPONSE DEGF |
| Media for Which Designed | REFRIGERANT 12 SINGLE RESPONSE |
| Thread Class | 2A ALL ENDS A |
| Material | IRON BODY |
| Material | RUBBER BUTADIENE-STYRENE CLASS SBR FLOW CONTROL DEVICE |
| Thread Series Designator | UNF ALL ENDS |
| Valve Operation Method | SOLENOID |
| Current Rating in Amps | 0.150 |
| Acquisition Status | ACTIVE |
| DEMIL Code | DEMIL A — No Demilitarization Required |
| Hazard | No hazard code in the DLA record (HMIC N) |
| Criticality Code | X |
| Reference | Meaning |
|---|---|
| RB3F2W/115VAC COIL | 3/9 Design control — primary reference U.S. Government activity |
| RB3F2W/115VAC COIL | 3/2 Design control — primary reference U.S. Government activity |
NSN 4810-00-134-8949 is a Valve,solenoid, classified under FSC 4810, Valves, Powered. Status: active.
Key specifications for 4810-00-134-8949: Flow Control Device: DIAPHRAGM; Phase: SINGLE; Frequency in Hertz: 50.0 AND 60.0; Voltage in Volts and Current Type: 115.0 AC. 19 specifications are documented in the U.S. Government catalog.
No hazard code in the DLA record (HMIC N). Hazard information on this page is shown exactly as it appears in the DLA record.
U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-16.
U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-18.