The Chest,field,water Quality Contro, cataloged under National Stock Number 4610-00-371-9687, is classified within Federal Supply Class 4610 (Water Purification Equipment) of the Water Purification and Sewage Treatment group. Government technical data includes 1 specification, cited from the U.S. Government catalog. 1 additional reference document (drawings, advisory and superseded references) is recorded in the U.S. Government catalog. Current acquisition status: Active.
| Parameter | Value |
|---|---|
| NSN | 4610-00-371-9687 |
| Item Name | Chest,field,water Quality Contro |
| FSC / FSG | 4610 / 46 — Water Purification Equipment |
| Status | ACTIVE |
| General Characteristics Item Description | C/O GENERAL ASSEMBLY,P/N D3898-1,BODY ASSEMBLY,LEFT HALF AND DETAILS,P/N D3898-2,BODY ASSEMBLY,RIGHT HALF AND DETAILS,P/N D3898-3,SUPPLY DRAWER L-1 ASSEMBLY AND DETAILS,P/N D3898-4,SPARE PARTS DRAWER L-2 ASSEMBLY AND DETAILS,P/N D3898-5,REAGENT DRAWER L-3 ASSEMBLY,P/N D3898-6,FLOCCULATION SET BOX ASSEMBLY,P/N D3898-7,FLOCCULATION BOX DETAILS,P/N D3898-8,SUPPLY DRAWER R-1 ASSEMBLY AND DETAILS,P/N D3898-9,INSTRUCTIONS AND REAGENT DRAWER ASSEMBLIES,P/N D3898-10,TURBIDIMETER DETAILS,P/N D3898-11,TURBIDIMETER DETAILS,P/N D3898-12,MISCELLANEOUS DETAILS,P/N D3898-13,LOADING DETAILS,P/N D3898-14 |
| Acquisition Status | ACTIVE |
| DEMIL Code | DEMIL A — No Demilitarization Required |
| Hazard | No hazard code in the DLA record (HMIC N) |
| Criticality Code | X |
| Reference | Meaning |
|---|---|
| D3898SH1T014 | 3/2 Design control — primary reference U.S. Government activity |
NSN 4610-00-371-9687 is a Chest,field,water Quality Contro, classified under FSC 4610, Water Purification Equipment. Status: active.
Key specifications for 4610-00-371-9687: General Characteristics Item Description: C/O GENERAL ASSEMBLY,P/N D3898-1,BODY ASSEMBLY,LEFT HALF AND DETAILS,P/N D3898-2,BODY ASSEMBLY,RIGHT HALF AND DETAILS,P/N D3898-3,SUPPLY DRAWER L-1 ASSEMBLY AND DETAILS,P/N D3898-4,SPARE PARTS DRAWER L-2 ASSEMBLY AND DETAILS,P/N D3898-5,REAGENT DRAWER L-3 ASSEMBLY,P/N D3898-6,FLOCCULATION SET BOX ASSEMBLY,P/N D3898-7,FLOCCULATION BOX DETAILS,P/N D3898-8,SUPPLY DRAWER R-1 ASSEMBLY AND DETAILS,P/N D3898-9,INSTRUCTIONS AND REAGENT DRAWER ASSEMBLIES,P/N D3898-10,TURBIDIMETER DETAILS,P/N D3898-11,TURBIDIMETER DETAILS,P/N D3898-12,MISCELLANEOUS DETAILS,P/N D3898-13,LOADING DETAILS,P/N D3898-14. 1 specification is documented in the U.S. Government catalog.
No hazard code in the DLA record (HMIC N). Hazard information on this page is shown exactly as it appears in the DLA record.
U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-16.
U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-18.