PartsTable
Technical Data Sheet
46005 ✓ Verified by PartsTable
Lindy · MRO · MRO_GENERAL
WHAT YOU NEED TO KNOW
Material determines chemical compatibility Standard durometer is 70 Shore A
Wrong material = catastrophic seal failure
PRODUCT OVERVIEW

CABLE ASSEMBLY,SPECIAL PURPOSE,E. Key specifications include length: 20.000 FEET NOMINAL FT, coupling: NOT INCLUDED, material: PLASTIC POLYVINYL CHLORIDE (PVC), end_style: 90 DEGREE PARALLEL, ring_style: STRAIGHT GAP, usage_design: EXTERNAL. This part is cataloged in the Federal Logistics Information System (FLIS) under NSN 5330-00-527-7332, indicating validated use in U.S.

government and defense logistics supply chains. Available through authorized enterprise resellers and TPM (Third Party Maintenance) channels. Verify compatibility with your specific system configuration before ordering.

WHERE IT FITS
MRO MRO_GENERAL 46005
NSN: 5330-00-527-7332
FSC: 5330
CAGE: 81076 — JOHNSON C S CO INC (USA)
SPECIFICATIONS
length20.000 FEET NOMINAL FT
couplingNOT INCLUDED
materialPLASTIC POLYVINYL CHLORIDE (PVC)
end_style90 DEGREE PARALLEL
ring_styleSTRAIGHT GAP
usage_designEXTERNAL
wall_thickness0.147 INCHES MINIMUM IN
inside_diameter0.546 INCHES NOMINAL IN
major_thickness0.027 INCHES NOMINAL IN
outside_diameter0.840 INCHES NOMINAL IN
surface_treatmentCADMIUM
operating_pressure230.0 POUNDS PER SQUARE INCH (PSI) MAXIMUM LBS
NSN5330-00-527-7332
COMPONENT DIAGRAM
O-RING / SEAL — MATERIAL DETERMINES APPLICATION ID: — CROSS-SECTION CS: — SPECIFICATION Material: — Durometer: — Temp: — PN: 46005 MFR: Lindy ⚠ VERIFY BEFORE ORDERING Wrong material = failure. Viton for oil/fuel, EPDM for water/steam, Buna-N for general purpose, Silicone for food-grade. Chemical incompatibility causes swelling, brittleness, or rapid degradation ✓ BROKER TIP Durometer (hardness) affects sealing pressure tolerance. Higher Shore A = harder = higher pressure. Standard durometer is 70A — verify if application requires different hardness PARTSTABLE TECHNICAL DRAWING — NOT TO SCALE
TYPICAL APPLICATIONS
  • Server Internal Cabling
  • Data Center Cable Infrastructure
  • SAS/SATA Drive Connectivity
VERIFIED SUBSTITUTES & CROSS-REFERENCES 29
985-9Interchangeable
interchangeable cross-reference
interchangeable
140120Interchangeable
interchangeable cross-reference
interchangeable
MIL-E-11276Interchangeable
interchangeable cross-reference
interchangeable
QPL11276Interchangeable
interchangeable cross-reference
interchangeable
62024Interchangeable
interchangeable cross-reference
interchangeable
ACM20Interchangeable
interchangeable cross-reference
interchangeable
LIFECYCLE
StatusCANCELLED
Availability
RoHS CompliantEAR99Not HAZMAT
Ready to buy 46005?
Compare prices from verified sellers on eBay
Buy on eBay →
As an eBay Partner, PartsTable may earn a commission. Your price is not affected.
FREQUENTLY ASKED QUESTIONS
What is 46005?
46005 is a CABLE ASSEMBLY,SPECIAL PURPOSE,E manufactured by Lindy. It is classified as a MRO (MRO_GENERAL).
What parts can replace 46005?
There are 29 known substitutes for 46005: 985-9, 140120, MIL-E-11276 and 26 more. Substitute compatibility should be verified for your specific system.
Is 46005 still available?
46005 is currently cancelled.
Community Feedback
Comments (0)
No comments yet. Be the first to share what you know.
Leave a Comment
Comments are reviewed before appearing. You will receive an email to verify before your comment appears.

Request a Quote — 46005