The Solenoid,sgl,safety, cataloged under National Stock Number 4410-01-459-4945, is classified within Federal Supply Class 4410 (Industrial Boilers) of the Furnace, Steam, Drying, Nuclear Reactors group. Government technical data includes 2 specifications, cited from the U.S. Government catalog. 2 additional reference documents (drawings, advisory and superseded references) are recorded in the U.S. Government catalog. Current acquisition status: Active.
| Parameter | Value |
|---|---|
| NSN | 4410-01-459-4945 |
| Item Name | Solenoid,sgl,safety |
| FSC / FSG | 4410 / 44 — Industrial Boilers |
| Status | ACTIVE |
| General Characteristics Item Description | THE SAFETY SYSTEM IS AN OVER-TEMPERATURE SAFETY SYSTEM WHICH WILL CLOSE THE MAIN CONTROL VALVE UPON AN OVER-TEMPERATURE CONDITION.THE SYSTEM UTILISES AN ASJUSTABLE ELECTRIC THERMOSTAT WHICH MONITORS THE TEMPERATURE OF THE WATER. IF AN OVER TEMPERATURE CONDITION IS DETECTED, THE THERMOSTAT SENDS AN ELECTRIC SIGNAL TO THE VALVE THUS CLOSING THE CONTROL VALVE. THE SYSTEM REQUIRES A 120 VOLT, 5 AMP CIRCUIT |
| Reference Data and Literature | TECHNICAL MANUAL FOR HOT WATER HEATER MODEL V670SWH6 |
| Acquisition Status | ACTIVE |
| DEMIL Code | DEMIL A — No Demilitarization Required |
| Hazard | No hazard code in the DLA record (HMIC N) |
| Criticality Code | X |
| Reference | Meaning |
|---|---|
| 960123 | D/9 Drawing number reference only U.S. Government activity |
| 960123-1C | 3/2 Design control — primary reference U.S. Government activity |
NSN 4410-01-459-4945 is a Solenoid,sgl,safety, classified under FSC 4410, Industrial Boilers. Status: active.
Key specifications for 4410-01-459-4945: General Characteristics Item Description: THE SAFETY SYSTEM IS AN OVER-TEMPERATURE SAFETY SYSTEM WHICH WILL CLOSE THE MAIN CONTROL VALVE UPON AN OVER-TEMPERATURE CONDITION.THE SYSTEM UTILISES AN ASJUSTABLE ELECTRIC THERMOSTAT WHICH MONITORS THE TEMPERATURE OF THE WATER. IF AN OVER TEMPERATURE CONDITION IS DETECTED, THE THERMOSTAT SENDS AN ELECTRIC SIGNAL TO THE VALVE THUS CLOSING THE CONTROL VALVE. THE SYSTEM REQUIRES A 120 VOLT, 5 AMP CIRCUIT; Reference Data and Literature: TECHNICAL MANUAL FOR HOT WATER HEATER MODEL V670SWH6; End Item Identification: USED ON CEMLINE HOT WATER HEATER, SWH SERIES, MODEL V670SWH624. 2 specifications are documented in the U.S. Government catalog.
No hazard code in the DLA record (HMIC N). Hazard information on this page is shown exactly as it appears in the DLA record.
U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-16.