The CAPACITOR,FIXED,ELECTROLYTIC is a the manufacturer cache protection component designed to preserve data integrity during power loss events in enterprise server and storage controller environments. Key specifications include body_style: W/O MTG FACILITIES, AXIAL TERMINALS, body_length: 0.686 INCHES NOMINAL IN, body_diameter: 0.274 INCHES MINIMUM AND 0.305 INCHES MAXIMUM IN, terminal_length: 1.500 INCHES NOMINAL IN, features_provided: HERMETICALLY SEALED CASE, terminal_diameter: 0.025 INCHES NOMINAL IN. This product is currently in active production with full OEM support.
This part is cataloged in the Federal Logistics Information System (FLIS) under NSN 5910-01-187-4868, indicating validated use in U.S. government and defense logistics supply chains. Available through authorized enterprise resellers and TPM (Third Party Maintenance) channels.
Verify compatibility with your specific system configuration before ordering.
| body_style | W/O MTG FACILITIES, AXIAL TERMINALS |
| body_length | 0.686 INCHES NOMINAL IN |
| body_diameter | 0.274 INCHES MINIMUM AND 0.305 INCHES MAXIMUM IN |
| terminal_length | 1.500 INCHES NOMINAL IN |
| features_provided | HERMETICALLY SEALED CASE |
| terminal_diameter | 0.025 INCHES NOMINAL IN |
| reliability_indicator | ESTABLISHED |
| electrical_polarization | POLARIZED |
| case_insulation_material | PLASTIC |
| nonderated_operating_temp | -85.0 CELSIUS MINIMUM DEGC |
| terminal_type_and_quantity | 2 UNINSULATED WIRE LEAD |
| specification/standard_data | 81349-MIL-C-39003/1 GOVERNMENT SPECIFICATION |
| NSN | 5910-01-187-4868 |
| TOLERANCE RANGE PER SECTION | -10.00 TO 10.00 PERCENT SINGLE SECTION |
| CAPACITIVE ELECTRODE MATERIAL | TANTALUM |
| CASE INSULATION MATERIAL | PLASTIC |
| DISSIPATION FACTOR AT REFERENCE TEMP IN PERCENT | 6.0000 |
| SPECIFICATION/STANDARD DATA | 81349-MIL-C-39003/1 GOVERNMENT SPECIFICATION |
| TEST DATA DOCUMENT | 81349-MIL-C-39003 SPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS, BROCHURES,ETC., THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS, INDUSTRY DIRECTORIES, AND SIMILAR TRADE PUBLICATIONS, REFLECTING GENERAL TYPE DATA ON CERTAIN ENVIRONMENTAL AND PERFORMANCE REQUIREMENTS AND TEST CONDITIONS THAT ARE SHOWN AS "TYPICAL", "AVERAGE", "NOMINAL", ETC.). |
| TERMINAL TYPE AND QUANTITY | 2 UNINSULATED WIRE LEAD |
| DC LEAKAGE AT REFERENCE TEMP | 2.500 MICROAMPERES |
| TERMINAL LENGTH | 1.500 INCHES NOMINAL IN |
| NONDERATED CONTINUOUS VOLTAGE RATING AND TYPE PER SECTION | 20.0 DC SINGLE SECTION |