438330-1: FILTER,BAND PASS.
The FILTER,BAND PASS is a the manufacturer industrial component. Key specifications include operating_temp_range: -55.0 TO 105.0 CELSIUS DEGC, load_impedance_per_function: 50.0 OHMS BLANK LOCATION NOT OTHERWISE SPECIFIED, input_terminal_identification: PDM517, reference_frequency_per_function: 1.0875 GIGAHERTZ BLANK LOCATION NOT OTHERWISE SPECIFIED, frequency_band_width_per_function: 1.0225 GIGAHERTZ BLANK AND 1.1525 GIGAHERTZ BLANK LOCATION NOT OTHERWISE SPECIFIED, source_impedance_rating_per_function: 50.0 OHMS BLANK LOCATION NOT OTHERWISE SPECIFIED. This part is cataloged in the U.S.
Government catalog under NSN 5915-00-502-4847, indicating validated use in U.S. government and defense logistics supply chains. Available through authorized enterprise resellers and TPM (Third Party Maintenance) channels.
Verify compatibility with your specific system configuration before ordering.
| operating_temp_range | -55.0 TO 105.0 CELSIUS DEGC |
| load_impedance_per_function | 50.0 OHMS BLANK LOCATION NOT OTHERWISE SPECIFIED |
| input_terminal_identification | PDM517 |
| reference_frequency_per_function | 1.0875 GIGAHERTZ BLANK LOCATION NOT OTHERWISE SPECIFIED |
| frequency_band_width_per_function | 1.0225 GIGAHERTZ BLANK AND 1.1525 GIGAHERTZ BLANK LOCATION NOT OTHERWISE SPECIFIED |
| source_impedance_rating_per_function | 50.0 OHMS BLANK LOCATION NOT OTHERWISE SPECIFIED |
| specified_frequencies_of_discrimination_per_function | 800.00 MEGAHERTZ BLANK AND 1.0225 GIGAHERTZ BLANK AND 1.1525 GIGAHERTZ BLANK AND 1.367 GIGAHERTZ BLANK LOCATION NOT OTHERWISE SPECIFIED |
| insertion_loss_at_reference_frequency_per_function_in_decibels | 1.2 BLANK LOCATION NOT OTHERWISE SPECIFIED |
| discrimination_at_specified_frequencies_per_function_in_decibels | 37.0 NOMINAL BLANK AND 1.0 NOMINAL BLANK FIRST FUNCTION |
| NSN | 5915-00-502-4847 |
| REFERENCE FREQUENCY PER FUNCTION | 1.0875 GIGAHERTZ BLANK LOCATION NOT OTHERWISE SPECIFIED |
| SOURCE IMPEDANCE RATING PER FUNCTION | 50.0 OHMS BLANK LOCATION NOT OTHERWISE SPECIFIED |
| DISCRIMINATION AT SPECIFIED FREQUENCIES PER FUNCTION IN DECIBELS | 37.0 NOMINAL BLANK AND 1.0 NOMINAL BLANK FIRST FUNCTION |
| FREQUENCY BAND WIDTH PER FUNCTION | 1.0225 GIGAHERTZ BLANK AND 1.1525 GIGAHERTZ BLANK LOCATION NOT OTHERWISE SPECIFIED |
| INPUT TERMINAL IDENTIFICATION | PDM517 |
| OPERATING TEMP RANGE | -55.0 TO 105.0 CELSIUS DEGC |
| INSERTION LOSS AT REFERENCE FREQUENCY PER FUNCTION IN DECIBELS | 1.2 BLANK LOCATION NOT OTHERWISE SPECIFIED |
| LOAD IMPEDANCE PER FUNCTION | 50.0 OHMS BLANK LOCATION NOT OTHERWISE SPECIFIED |
| SPECIFIED FREQUENCIES OF DISCRIMINATION PER FUNCTION | 800.00 MEGAHERTZ BLANK AND 1.0225 GIGAHERTZ BLANK AND 1.1525 GIGAHERTZ BLANK AND 1.367 GIGAHERTZ BLANK LOCATION NOT OTHERWISE SPECIFIED |