PartsTable TECHNICAL DATA SHEET
NSN 4140-01-319-6353Government record, cited

Fan, Vaneaxial4140-01-319-6353

NSN 4140-01-319-6353 · NIIN 013196353
FSC 4140 — Fans, Air Circulators, and Blower Equipment · FSG 41 — Refrigeration, AC, and Air Circulating Equipment
Government record, cited
Also searched as  4140-01-319-6353 · 4140013196353 · NIIN 013196353 · 01-319-6353 · FSC 4140 Fans, Air Circulators, and Blower Equipment · MILF18953TYPEA · A1/2A1W6 ARR.4 · A1/2A1W6 ARR.4 · 9W-57010 · 9W-57010,CD-336 1
Nearby stock numbers  ·
Features
  • Fan,vaneaxial — FSC 4140
  • Mounting Facility Type and Quantity: 1 FLANGE AND 14 UNTHREADED HOLE(S)
  • Speed Adjustments: SINGLE SPEED
  • Phase: SINGLE
  • Frequency in Hertz: 60.0
  • Inclosure Type: FULLY INCLOSED
  • Length: 15.375 INCHES NOMINAL IN
  • Voltage in Volts and Current Type: 115.0 AC
Identification
  • NSN: 4140-01-319-6353
  • NIIN: 013196353
  • FSC: 4140 — Fans, Air Circulators, and Blower Equipment
  • FSG: 41 — Refrigeration, AC, and Air Circulating Equipment
General Description

The Fan,vaneaxial, cataloged under National Stock Number 4140-01-319-6353, is classified within Federal Supply Class 4140 (Fans, Air Circulators, and Blower Equipment) of the Refrigeration, AC, and Air Circulating Equipment group. Government technical data includes 23 specifications, cited from the U.S. Government catalog. 9 additional reference documents (drawings, advisory and superseded references) are recorded in the U.S. Government catalog. Current acquisition status: Active.

Technical Specifications
ParameterValue
NSN4140-01-319-6353
Item NameFan,vaneaxial
FSC / FSG4140 / 41 — Fans, Air Circulators, and Blower Equipment
StatusACTIVE
Mounting Facility Type and Quantity1 FLANGE AND 14 UNTHREADED HOLE(S)
Speed AdjustmentsSINGLE SPEED
PhaseSINGLE
Frequency in Hertz60.0
Inclosure TypeFULLY INCLOSED
Length15.375 INCHES NOMINAL IN
Voltage in Volts and Current Type115.0 AC
Flow DirectionINWARD
Housing Inside Diameter10.502 INCHES MINIMUM AND 10.505 INCHES MAXIMUM IN
Drive TypeDIRECT
Prime Mover Power Rating0.333 HORSEPOWER
Style DesignatorFIXED
Ambient Temp at Full Rated Power65.0 CELSIUS DEGC
Operating Speed at Rated Capacity in RPM3450.0
Environmental ProtectionSPRAY TIGHT
MaterialSTEEL HOUSING
MaterialALUMINUM BLADE
Prime Mover TypeELECTRIC MOTOR
Rotation Direction for Which DesignedCOUNTERCLOCKWISE
Prime Mover Drive Shaft Bearing TypeBALL
Electrical Connection TypeTERMINAL
Static Pressure at Specified Air Flow RateERR-060
Air Flow Rate500.0 CUBIC FEET PER MINUTE NOMINAL
Lifecycle & Compliance
Acquisition StatusACTIVE
DEMIL CodeDEMIL A — No Demilitarization Required
HazardNo hazard code in the DLA record (HMIC N)
Criticality CodeX
Cross-Reference Index
No manufacturer part numbers on file in the U.S. Government catalog.
Reference documents
ReferenceMeaning
MILF18953TYPEA C/1 Advisory reference — outside the item-of-supply concept
Zf Industrieantriebe Witten Gmbh
A1/2A1W6 ARR.4 5/1 Secondary reference
Fm Af, Llc Dba American Fan Company
A1/2A1W6 ARR.4 5/9 Secondary reference
New Philadelphia Fan Co Buffalo Forge Marine Fans
9W-57010 5/9 Secondary reference
New Philadelphia Fan Co Buffalo Forge Marine Fans
9W-57010,CD-336 1 C/1 Advisory reference — outside the item-of-supply concept
Zf Industrieantriebe Witten Gmbh
M18953-AA00HA1W6NANANA 2/2 Government specification standardization
U.S. Government activity
MIL-PRF-18953 4/1 Identification reference
U.S. Government activity
A1/2A1W6 5/9 Secondary reference
U.S. Government activity
9W-57010 5/1 Secondary reference
Fm Af, Llc Dba American Fan Company

Frequently Asked Questions

What is NSN 4140-01-319-6353?

NSN 4140-01-319-6353 is a Fan,vaneaxial, classified under FSC 4140, Fans, Air Circulators, and Blower Equipment. Status: active.

What are the specifications of 4140-01-319-6353?

Key specifications for 4140-01-319-6353: Mounting Facility Type and Quantity: 1 FLANGE AND 14 UNTHREADED HOLE(S); Speed Adjustments: SINGLE SPEED; Phase: SINGLE; Frequency in Hertz: 60.0. 23 specifications are documented in the U.S. Government catalog.

Is NSN 4140-01-319-6353 hazardous material?

No hazard code in the DLA record (HMIC N). Hazard information on this page is shown exactly as it appears in the DLA record.

Sources

U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-16.

U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-18.

✓ Data cited from the U.S. Government catalog; commercial cross-references from OEM and certified industry sources.
PartsTable Design LLC · partstable.com