PartsTable TECHNICAL DATA SHEET
NSN 4140-00-150-6077Government record, cited

Fan, Tubeaxial4140-00-150-6077

NSN 4140-00-150-6077 · NIIN 001506077
FSC 4140 — Fans, Air Circulators, and Blower Equipment · FSG 41 — Refrigeration, AC, and Air Circulating Equipment
Government record, cited
Also searched as  4140-00-150-6077 · 4140001506077 · NIIN 001506077 · 00-150-6077 · FSC 4140 Fans, Air Circulators, and Blower Equipment · 0N123037-4 · 026993 W/476646 · SAUCER 654DS W/14559
Nearby stock numbers  ·
Features
  • Fan,tubeaxial — FSC 4140
  • Mounting Facility Type and Quantity: 2 RIM
  • Speed Adjustments: SINGLE SPEED
  • Phase: SINGLE
  • Frequency in Hertz: 400.0
  • Inclosure Type: FULLY INCLOSED
  • Length: 2.500 INCHES NOMINAL IN
  • Voltage in Volts and Current Type: 115.0 AC
Identification
  • NSN: 4140-00-150-6077
  • NIIN: 001506077
  • FSC: 4140 — Fans, Air Circulators, and Blower Equipment
  • FSG: 41 — Refrigeration, AC, and Air Circulating Equipment
General Description

The Fan,tubeaxial, cataloged under National Stock Number 4140-00-150-6077, is classified within Federal Supply Class 4140 (Fans, Air Circulators, and Blower Equipment) of the Refrigeration, AC, and Air Circulating Equipment group. Government technical data includes 23 specifications, cited from the U.S. Government catalog. 3 additional reference documents (drawings, advisory and superseded references) are recorded in the U.S. Government catalog. Current acquisition status: Active.

Technical Specifications
ParameterValue
NSN4140-00-150-6077
Item NameFan,tubeaxial
FSC / FSG4140 / 41 — Fans, Air Circulators, and Blower Equipment
StatusACTIVE
Mounting Facility Type and Quantity2 RIM
Speed AdjustmentsSINGLE SPEED
PhaseSINGLE
Frequency in Hertz400.0
Inclosure TypeFULLY INCLOSED
Length2.500 INCHES NOMINAL IN
Voltage in Volts and Current Type115.0 AC
Flow DirectionINWARD
Surface Treatment Document and ClassificationTT-E-489,TYPE B FED SPEC SINGLE TREATMENT RESPONSE OVERALL
Housing Inside Diameter6.812 INCHES NOMINAL IN
Drive TypeDIRECT
Prime Mover Power Rating31.000 WATTS
Style DesignatorFIXED
Features ProvidedSAFETY IMPELLER GUARD
Ambient Temp at Full Rated Power125.0 CELSIUS DEGC
Operating Speed at Rated Capacity in RPM3650.0
Surface TreatmentENAMEL OVERALL
MaterialALUMINUM ALLOY OVERALL
Prime Mover TypeELECTRIC MOTOR
Rotation Direction for Which DesignedCLOCKWISE
Prime Mover Drive Shaft Bearing TypeBALL
Electrical Connection TypeTERMINAL BOX
Air Flow Rate315.0 CUBIC FEET PER MINUTE NOMINAL
Lifecycle & Compliance
Acquisition StatusACTIVE
DEMIL CodeDEMIL A — No Demilitarization Required
HazardNo hazard code in the DLA record (HMIC N)
Criticality CodeX
Cross-Reference Index
No manufacturer part numbers on file in the U.S. Government catalog.
Reference documents
ReferenceMeaning
0N123037-4 7/2 Vendor item drawing reference
U.S. Government activity
026993 W/476646 3/2 Design control — primary reference
U.S. Government activity
SAUCER 654DS W/14559 5/9 Secondary reference
U.S. Government activity
No interchangeability data on file.
Other items in FSC 4140 — Fans, Air Circulators, and Blower Equipment
Items in the same Federal Supply class. No interchangeability or substitution relationship is implied.
4140-00-000-0082
IMPELLER,FAN,AXIAL
4140-00-001-1517
FAN,CENTRIFUGAL
4140-00-001-1536
FAN,VENTILATING
4140-00-001-1537
4140-00-001-1537 · Item name not on file
4140-00-001-3930
4140-00-001-3930 · Item name not on file
4140-00-001-6464
4140-00-001-6464 · Item name not on file
4140-00-001-6874
4140-00-001-6874 · Item name not on file
4140-00-001-6875
4140-00-001-6875 · Item name not on file

Frequently Asked Questions

What is NSN 4140-00-150-6077?

NSN 4140-00-150-6077 is a Fan,tubeaxial, classified under FSC 4140, Fans, Air Circulators, and Blower Equipment. Status: active.

What are the specifications of 4140-00-150-6077?

Key specifications for 4140-00-150-6077: Mounting Facility Type and Quantity: 2 RIM; Speed Adjustments: SINGLE SPEED; Phase: SINGLE; Frequency in Hertz: 400.0. 23 specifications are documented in the U.S. Government catalog.

Is NSN 4140-00-150-6077 hazardous material?

No hazard code in the DLA record (HMIC N). Hazard information on this page is shown exactly as it appears in the DLA record.

Sources

U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-16.

U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-18.

✓ Data cited from the U.S. Government catalog; commercial cross-references from OEM and certified industry sources.
PartsTable Design LLC · partstable.com