The Chiller,water,refrigerating, cataloged under National Stock Number 4130-00-352-0534, is classified within Federal Supply Class 4130 (Refrigeration and Air Conditioning Components) of the Refrigeration, AC, and Air Circulating Equipment group. Government technical data includes 21 specifications, cited from the U.S. Government catalog. 2 additional reference documents (drawings, advisory and superseded references) are recorded in the U.S. Government catalog. Current acquisition status: Active.
| Parameter | Value |
|---|---|
| NSN | 4130-00-352-0534 |
| Item Name | Chiller,water,refrigerating |
| FSC / FSG | 4130 / 41 — Refrigeration and Air Conditioning Components |
| Status | ACTIVE |
| Refrigerant Outlet Connection Quantity | 1 |
| Effective Cooling Area | 0.550 SQUARE FEET |
| Refrigerant Side Test Minimum Pressure | 225.0 POUNDS PER SQUARE INCH LBS |
| Tube Type | COILED |
| Water Connection Quantity | 2 |
| Water Connection Size | 1/4 IN. IPS IN |
| Mounting Position | VERTICAL |
| Refrigerant Operating Location | IN TUBES |
| Water Side Test Minimum Pressure | 225.0 POUNDS PER SQUARE INCH LBS |
| Refrigerant Inlet Connection Type | TUBE |
| Refrigerant Outlet Connection Type | TUBE |
| Refrigerant Inlet Connection Size | 5/8 IN. IN |
| Water Connection Type | PIPE |
| Shell Length | 9.688 INCHES IN |
| Shell Outside Diameter | 6.750 INCHES IN |
| Refrigerant Inlet Connection Quantity | 1 |
| Water for Which Designed | FRESH |
| Refrigerant Outlet Connection Size | 5/8 IN. IN |
| Material | COPPER TUBE |
| Material | ALUMINUM SHELL |
| Media for Which Designed | FREON 12 USE REFRIGERANT R-12 |
| Acquisition Status | ACTIVE |
| DEMIL Code | DEMIL A — No Demilitarization Required |
| Hazard | No hazard code in the DLA record (HMIC N) |
| Criticality Code | X |
| Reference | Meaning |
|---|---|
| HX15M1 | 5/9 Secondary reference Hartford Compressors Inc |
| HX15M1 | 3/9 Design control — primary reference Marshall Engineered Products Co Dba Mepco |
NSN 4130-00-352-0534 is a Chiller,water,refrigerating, classified under FSC 4130, Refrigeration and Air Conditioning Components. Status: active.
Key specifications for 4130-00-352-0534: Refrigerant Outlet Connection Quantity: 1; Effective Cooling Area: 0.550 SQUARE FEET; Refrigerant Side Test Minimum Pressure: 225.0 POUNDS PER SQUARE INCH LBS; Tube Type: COILED. 21 specifications are documented in the U.S. Government catalog.
No hazard code in the DLA record (HMIC N). Hazard information on this page is shown exactly as it appears in the DLA record.