PartsTable TECHNICAL DATA SHEET
NSN 4130-00-276-1036Government record, cited

Condensing Unit, Refrigerating4130-00-276-1036

NSN 4130-00-276-1036 · NIIN 002761036
FSC 4130 — Refrigeration and Air Conditioning Components · FSG 41 — Refrigeration, AC, and Air Circulating Equipment
Government record, cited
Also searched as  4130-00-276-1036 · 4130002761036 · NIIN 002761036 · 00-276-1036 · FSC 4130 Refrigeration and Air Conditioning Components · 51MRD1186N1 · S5901H1230574
Nearby stock numbers  ·
Features
  • Condensing Unit,refrigerating — FSC 4130
  • Refrigeration Flow Rate in Tons Per Hour: 0.500
  • Phase: THREE
  • Condenser Heat Transfer Area: 15.700 SQUARE FEET
  • Separate Liquid Receiver Capacity: 1.000 CUBIC FEET
  • Frequency in Hertz: 60.000
  • Drive Type: BELT
  • Compressing Unit Design Type: OPEN
Identification
  • NSN: 4130-00-276-1036
  • NIIN: 002761036
  • FSC: 4130 — Refrigeration and Air Conditioning Components
  • FSG: 41 — Refrigeration, AC, and Air Circulating Equipment
General Description

The Condensing Unit,refrigerating, cataloged under National Stock Number 4130-00-276-1036, is classified within Federal Supply Class 4130 (Refrigeration and Air Conditioning Components) of the Refrigeration, AC, and Air Circulating Equipment group. Government technical data includes 28 specifications, cited from the U.S. Government catalog. 2 additional reference documents (drawings, advisory and superseded references) are recorded in the U.S. Government catalog. Current acquisition status: Active.

Technical Specifications
ParameterValue
NSN4130-00-276-1036
Item NameCondensing Unit,refrigerating
FSC / FSG4130 / 41 — Refrigeration and Air Conditioning Components
StatusACTIVE
Refrigeration Flow Rate in Tons Per Hour0.500
PhaseTHREE
Condenser Heat Transfer Area15.700 SQUARE FEET
Separate Liquid Receiver Capacity1.000 CUBIC FEET
Frequency in Hertz60.000
Drive TypeBELT
Compressing Unit Design TypeOPEN
Compressing Unit Cylinder Quantity2
Discharge Pressure126.2 POUNDS PER SQUARE INCH GAGE LBS
Compressing Unit TypeRECIPROCATING
Compressing Unit Stroke Length2.000 INCHES IN
Compressor Speed at Rated Capacity in RPM940.000
Compressing Unit Cylinder Bore Diameter2.500 INCHES NOMINAL IN
Prime Mover Horsepower Rating3.000
Electric Motor Quantity1
Condenser Cooling MediumWATER
Ambient Temp110.000 FAHRENHEIT DEGF
Component for Which DesignedCOMPRESSOR
Suction PressureERR-060
Condenser Shell Outside Diameter6.625 INCHES NOMINAL IN
Compressor Cooling MediumAIR
Operating Speed at Rated Capacity in RPM1750.000
Water for Which DesignedSALT
Condenser TypeSHELL OR TUBE
Condenser Overall Length71.188 INCHES NOMINAL IN
Prime Mover TypeELECTRIC MOTOR
Media for Which DesignedFREON 12 USE REFRIGERANT R-12
Reference Number Differentiating CharacteristicsAKDJ,AWLX,AHZX,AWLY,ACDC,ELEC,FREQ,FAAZ,AEQC
Lifecycle & Compliance
Acquisition StatusACTIVE
DEMIL CodeDEMIL A — No Demilitarization Required
HazardNo hazard code in the DLA record (HMIC N)
Criticality CodeX
Cross-Reference Index
No manufacturer part numbers on file in the U.S. Government catalog.
Reference documents
ReferenceMeaning
51MRD1186N1 3/1 Design control — primary reference
Carrier Corp
S5901H1230574 5/1 Secondary reference
U.S. Government activity
No interchangeability data on file.
Other items in FSC 4130 — Refrigeration and Air Conditioning Components
Items in the same Federal Supply class. No interchangeability or substitution relationship is implied.
4130-00-000-0147
FILTER MEDIA,AIR CONDITIONING
4130-00-000-0166
4130-00-000-0166 · Item name not on file
4130-00-001-6584
4130-00-001-6584 · Item name not on file
4130-00-001-7999
4130-00-001-7999 · Item name not on file
4130-00-001-8020
4130-00-001-8020 · Item name not on file
4130-00-001-9120
COMPRESSOR UNIT,REFRIGERATION
4130-00-001-9410
4130-00-001-9410 · Item name not on file
4130-00-001-9424
4130-00-001-9424 · Item name not on file

Frequently Asked Questions

What is NSN 4130-00-276-1036?

NSN 4130-00-276-1036 is a Condensing Unit,refrigerating, classified under FSC 4130, Refrigeration and Air Conditioning Components. Status: active.

What are the specifications of 4130-00-276-1036?

Key specifications for 4130-00-276-1036: Refrigeration Flow Rate in Tons Per Hour: 0.500; Phase: THREE; Condenser Heat Transfer Area: 15.700 SQUARE FEET; Separate Liquid Receiver Capacity: 1.000 CUBIC FEET. 28 specifications are documented in the U.S. Government catalog.

Is NSN 4130-00-276-1036 hazardous material?

No hazard code in the DLA record (HMIC N). Hazard information on this page is shown exactly as it appears in the DLA record.

Sources

U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-16.

U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-18.

✓ Data cited from the U.S. Government catalog; commercial cross-references from OEM and certified industry sources.
PartsTable Design LLC · partstable.com