The Condensing Unit,refrigerating, cataloged under National Stock Number 4130-00-266-9676, is classified within Federal Supply Class 4130 (Refrigeration and Air Conditioning Components) of the Refrigeration, AC, and Air Circulating Equipment group. Government technical data includes 23 specifications, cited from the U.S. Government catalog. 3 additional reference documents (drawings, advisory and superseded references) are recorded in the U.S. Government catalog. Current acquisition status: Active.
| Parameter | Value |
|---|---|
| NSN | 4130-00-266-9676 |
| Item Name | Condensing Unit,refrigerating |
| FSC / FSG | 4130 / 41 — Refrigeration and Air Conditioning Components |
| Status | ACTIVE |
| Refrigeration Flow Rate in Tons Per Hour | 0.250 |
| Phase | SINGLE |
| Condenser Heat Transfer Area | 164.000 SQUARE FEET |
| Separate Liquid Receiver Capacity | 0.400 CUBIC FEET |
| Drive Type | BELT |
| Compressing Unit Design Type | OPEN |
| Compressing Unit Cylinder Quantity | 2 |
| Compressing Unit Type | RECIPROCATING |
| Compressing Unit Stroke Length | 2.000 INCHES IN |
| Compressor Speed at Rated Capacity in RPM | 925.000 |
| Compressing Unit Cylinder Bore Diameter | 2.500 INCHES NOMINAL IN |
| Prime Mover Horsepower Rating | 2.000 |
| Electric Motor Quantity | 1 |
| Condenser Cooling Medium | AIR |
| Ambient Temp | 120.000 FAHRENHEIT DEGF |
| Component for Which Designed | COMPRESSOR |
| Suction Pressure | ERR-060 |
| Compressor Cooling Medium | AIR |
| Operating Speed at Rated Capacity in RPM | 1750.000 |
| Condenser Type | FIN OR TUBE |
| Prime Mover Type | ELECTRIC MOTOR |
| Media for Which Designed | FREON 12 USE REFRIGERANT R-12 |
| Reference Number Differentiating Characteristics | AAYE,AAYF,AAYM,ANDX |
| Acquisition Status | ACTIVE |
| DEMIL Code | DEMIL A — No Demilitarization Required |
| Hazard | No hazard code in the DLA record (HMIC N) |
| Criticality Code | X |
| Reference | Meaning |
|---|---|
| S5901F3118487 | 5/1 Secondary reference U.S. Government activity |
| N2200-1 | 3/1 Design control — primary reference Carrier Corp |
| N220-1 | 5/9 Secondary reference Carrier Corp |
NSN 4130-00-266-9676 is a Condensing Unit,refrigerating, classified under FSC 4130, Refrigeration and Air Conditioning Components. Status: active.
Key specifications for 4130-00-266-9676: Refrigeration Flow Rate in Tons Per Hour: 0.250; Phase: SINGLE; Condenser Heat Transfer Area: 164.000 SQUARE FEET; Separate Liquid Receiver Capacity: 0.400 CUBIC FEET. 23 specifications are documented in the U.S. Government catalog.
No hazard code in the DLA record (HMIC N). Hazard information on this page is shown exactly as it appears in the DLA record.
U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-16.
U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-18.