The Chiller,water,refrigerating, cataloged under National Stock Number 4130-00-113-8232, is classified within Federal Supply Class 4130 (Refrigeration and Air Conditioning Components) of the Refrigeration, AC, and Air Circulating Equipment group. Government technical data includes 17 specifications, cited from the U.S. Government catalog. 2 additional reference documents (drawings, advisory and superseded references) are recorded in the U.S. Government catalog. Current acquisition status: Active.
| Parameter | Value |
|---|---|
| NSN | 4130-00-113-8232 |
| Item Name | Chiller,water,refrigerating |
| FSC / FSG | 4130 / 41 — Refrigeration and Air Conditioning Components |
| Status | ACTIVE |
| Refrigerant Outlet Connection Quantity | 2 |
| Effective Cooling Area | 169.000 SQUARE FEET |
| Refrigerant Side Test Minimum Pressure | 225.0 POUNDS PER SQUARE INCH LBS |
| Water Connection Quantity | 2 |
| Water Connection Size | 2-1/2 IN. N STD IN |
| Mounting Position | HORIZONTAL |
| Refrigerant Operating Location | IN TUBES |
| Water Side Test Minimum Pressure | 225.0 POUNDS PER SQUARE INCH LBS |
| Refrigerant Inlet Connection Size | 1-5/8 IN. IN |
| Shell Length | 6.500 FEET FT |
| Shell Outside Diameter | 12.875 INCHES IN |
| Refrigerant Inlet Connection Quantity | 1 |
| Refrigerant Outlet Connection Size | 2-5/8 IN. IN |
| Material | COPPER TUBE |
| Material | COPPER ALLOY SHELL |
| Media for Which Designed | REFRIGERANT 12 |
| Reference Number Differentiating Characteristics | FOR25 TON NONMAGNETIC AIR CONDITIONING PLANT |
| Acquisition Status | ACTIVE |
| DEMIL Code | DEMIL A — No Demilitarization Required |
| Hazard | No hazard code in the DLA record (HMIC N) |
| Criticality Code | X |
| Reference | Meaning |
|---|---|
| 7800E5374N2 | 5/1 Secondary reference Carrier Corp |
| 10M28-704 | 3/1 Design control — primary reference Carrier Corp |
NSN 4130-00-113-8232 is a Chiller,water,refrigerating, classified under FSC 4130, Refrigeration and Air Conditioning Components. Status: active.
Key specifications for 4130-00-113-8232: Refrigerant Outlet Connection Quantity: 2; Effective Cooling Area: 169.000 SQUARE FEET; Refrigerant Side Test Minimum Pressure: 225.0 POUNDS PER SQUARE INCH LBS; Water Connection Quantity: 2. 17 specifications are documented in the U.S. Government catalog.
No hazard code in the DLA record (HMIC N). Hazard information on this page is shown exactly as it appears in the DLA record.
U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-16.
U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-18.