PartsTable TECHNICAL DATA SHEET
NSN 4110-01-024-1654Government record, cited

Freezer, Mechanical, Food4110-01-024-1654

NSN 4110-01-024-1654 · NIIN 010241654
FSC 4110 — Refrigeration Equipment · FSG 41 — Refrigeration, AC, and Air Circulating Equipment
Government record, cited
Also searched as  4110-01-024-1654 · 4110010241654 · NIIN 010241654 · 01-024-1654 · FSC 4110 Refrigeration Equipment · A-A-50154 · NAV-15-LTCT
Nearby stock numbers  ·
Features
  • Freezer,mechanical,food — FSC 4110
  • Phase: SINGLE
  • Condenser Unit Quantity: 1
  • Capacity and Location: 14.000 CUBIC FEET MINIMUM STORAGE
  • AC Voltage Rating: 115.0 VOLTS NOMINAL
  • Current Type: AC
  • Usage Design: COMMERCIAL
  • Evaporator: INCLUDED
Identification
  • NSN: 4110-01-024-1654
  • NIIN: 010241654
  • FSC: 4110 — Refrigeration Equipment
  • FSG: 41 — Refrigeration, AC, and Air Circulating Equipment
General Description

The Freezer,mechanical,food, cataloged under National Stock Number 4110-01-024-1654, is classified within Federal Supply Class 4110 (Refrigeration Equipment) of the Refrigeration, AC, and Air Circulating Equipment group. Government technical data includes 22 specifications, cited from the U.S. Government catalog. 2 additional reference documents (drawings, advisory and superseded references) are recorded in the U.S. Government catalog. 1 item shares a part number with this NSN in the catalog (possible match — not a government interchangeability claim). Current acquisition status: Active.

Technical Specifications
ParameterValue
NSN4110-01-024-1654
Item NameFreezer,mechanical,food
FSC / FSG4110 / 41 — Refrigeration Equipment
StatusACTIVE
PhaseSINGLE
Condenser Unit Quantity1
Capacity and Location14.000 CUBIC FEET MINIMUM STORAGE
AC Voltage Rating115.0 VOLTS NOMINAL
Current TypeAC
Usage DesignCOMMERCIAL
EvaporatorINCLUDED
Winding PhaseSINGLE
Power SourceELECTRIC MOTOR
Prime Mover Horsepower Rating0.333
Evaporator Unit TypeFORCED AIR-COOLING OR GRAVITY CONVECTION
Accessory Components and QuantitySHELVES,2
AC Frequency Rating60.0 HERTZ NOMINAL
Unit TypeBASE CABINET W/ WORK TOP
Condenser Unit LocationCABINET
Frequency Rating60.0 HERTZ NOMINAL
Condenser TypeHERMETICALLY SEALED
Door Quantity2
MaterialSTEEL CORROSION RESISTING OUTSIDE SHELL
Voltage Rating115.0 VOLTS NOMINAL
Condenser Cooling TypeAIR
Reference Number Differentiating CharacteristicsAS DIFFERENTIATED BY VOLTAGE RATING AND FREQUENCY RATING
Lifecycle & Compliance
Acquisition StatusACTIVE
DEMIL CodeDEMIL A — No Demilitarization Required
HazardNo hazard code in the DLA record (HMIC N)
Criticality CodeX
⇄ Related Items 1
Each row states its source: a government interchangeability/replacement code, or a possible match on a shared part number.
4110-01-024-1655NAV-15-LTCT 220V POSSIBLE MATCH
FREEZER,MECHANICAL,FOOD
Possible match (shared part number)Atmost Refrigeration Company, Inc. Div Atmost Refrigeration
Cross-Reference Index
No manufacturer part numbers on file in the U.S. Government catalog.
Reference documents
ReferenceMeaning
A-A-50154 5/9 Secondary reference
Federal Commercial Item Description Promulgated by General Services Administration Washington DC
NAV-15-LTCT 3/1 Design control — primary reference
Atmost Refrigeration Company, Inc. Div Atmost Refrigeration
Related Parts
4110-01-024-1655POSSIBLE MATCH
FREEZER,MECHANICAL,FOOD
NAV-15-LTCT 220V

Frequently Asked Questions

What is NSN 4110-01-024-1654?

NSN 4110-01-024-1654 is a Freezer,mechanical,food, classified under FSC 4110, Refrigeration Equipment. Status: active.

What NSN replaces 4110-01-024-1654?

1 possible match (shared part number, not a government interchangeability claim): 4110-01-024-1655. Verify interchangeability with system specifications before substitution.

What are the specifications of 4110-01-024-1654?

Key specifications for 4110-01-024-1654: Overall Height: 36.000 INCHES NOMINAL IN; Phase: SINGLE; Condenser Unit Quantity: 1; Capacity and Location: 14.000 CUBIC FEET MINIMUM STORAGE. 22 specifications are documented in the U.S. Government catalog.

Is NSN 4110-01-024-1654 hazardous material?

No hazard code in the DLA record (HMIC N). Hazard information on this page is shown exactly as it appears in the DLA record.

Sources

U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-16.

U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-18.

✓ Data cited from the U.S. Government catalog; commercial cross-references from OEM and certified industry sources.
PartsTable Design LLC · partstable.com