PartsTable
Technical Data Sheet
Download PDF

400-851 — RELAY,ELECTROMAGNETIC

✓ Government record, cited
— · COMPONENT
PRODUCT OVERVIEW

400-851: RELAY,ELECTROMAGNETIC.

The RELAY,ELECTROMAGNETIC is a the manufacturer industrial component. Key specifications include material: STEEL OVERALL, duty_type: CONTINUOUS, thread_class: 2B SINGLE MOUNTING FACILITY, overall_width: 1.000 INCHES NOMINAL IN, overall_height: 0.813 INCHES MINIMUM AND 0.998 INCHES MAXIMUM IN, overall_length: 1.560 INCHES NOMINAL IN. This part is cataloged in the U.S.

Government catalog under NSN 5945-00-250-5588, indicating validated use in U.S. government and defense logistics supply chains. Available through authorized enterprise resellers and TPM (Third Party Maintenance) channels.

Verify compatibility with your specific system configuration before ordering.

WHERE IT FITS
400-851
NSN: 5945-00-250-5588
NIINs: 002505588, 010318727, 012262654
FSC: 5945 — Relays and Solenoids
CAGE: 62143 — NORTHERN TELECOM INC TELECOM DISTRIBUTION DIV (USA)
SPECIFICATIONS
materialSTEEL OVERALL
duty_typeCONTINUOUS
cam_quantity2
thread_class2B SINGLE MOUNTING FACILITY
coil_quantity1
overall_width1.000 INCHES NOMINAL IN
overall_height0.813 INCHES MINIMUM AND 0.998 INCHES MAXIMUM IN
overall_length1.560 INCHES NOMINAL IN
sealing_length0.573 INCHES MINIMUM AND 0.619 INCHES MAXIMUM IN
outside_diameter2.266 INCHES NOMINAL IN
overall_diameter3.130 INCHES MINIMUM AND 3.155 INCHES MAXIMUM IN
special_featuresDRILL 0.156 HOLE IN SIDE
NSN5945-00-250-5588
COMPONENT DIAGRAM
COMPONENT MAIN IC EDGE CONNECTOR No detailed specs available RELAY,ELECTROMAGNETIC TITLE COMPONENT PN 400-851 MFR RELAY,ELECTROMAGNETIC
KEY FEATURES
•
MOUNTING FACILITY TYPE AND QUANTITY: 2 THREADED HOLE(S) SINGLE MOUNTING FACILITY
•
PILE-UP MAIN CONTACT FORM ARRANGEMENT: 2A AND 2C A
•
MAIN CONTACT MAXIMUM VOLTAGE RATING IN VOLTS: 300.0 AC AND 6.0 DC
•
MOUNTING FACILITY PATTERN: DIAGONAL SINGLE MOUNTING FACILITY
•
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH: 0.692 INCHES NOMINAL SINGLE MOUNTING FACILITY IN
•
MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE: 250.0 MILLIAMPERES AC AND 6.0 AMPERES DC RESISTIVE LOAD
•
DUTY TYPE: CONTINUOUS
TECHNICAL CHARACTERISTICS
MOUNTING FACILITY TYPE AND QUANTITY2 THREADED HOLE(S) SINGLE MOUNTING FACILITY
OVERALL HEIGHT1.620 INCHES NOMINAL IN
PILE-UP MAIN CONTACT FORM ARRANGEMENT2A AND 2C A
MAIN CONTACT MAXIMUM VOLTAGE RATING IN VOLTS300.0 AC AND 6.0 DC
MOUNTING FACILITY PATTERNDIAGONAL SINGLE MOUNTING FACILITY
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH0.692 INCHES NOMINAL SINGLE MOUNTING FACILITY IN
MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE250.0 MILLIAMPERES AC AND 6.0 AMPERES DC RESISTIVE LOAD
DUTY TYPECONTINUOUS
OVERALL LENGTH1.560 INCHES NOMINAL IN
OVERALL WIDTH1.000 INCHES NOMINAL IN
SUBSTITUTES & CROSS-REFERENCES 1
71-5229P1Same NSN cross-reference
Same NSN cross-reference
Also cataloged under this NSN
LIFECYCLE
NSN statusActive· U.S. Government catalog
Acquisition advice: Semi-active item — no replacement plannedNo demilitarization required
Ready to buy 400-851?
Compare prices from verified sellers on eBay
Buy on eBay →
As an eBay Partner, PartsTable may earn a commission. Your price is not affected.
FREQUENTLY ASKED QUESTIONS
What is 400-851?
400-851 is a RELAY,ELECTROMAGNETIC.
What parts can replace 400-851?
There is 1 known substitute for 400-851: 71-5229P1. Substitute compatibility should be verified for your specific system.
What is the NSN for 400-851?
400-851 is cataloged in the U.S. Government catalog under NSN 5945-00-250-5588. This indicates validated use in U.S. government and defense supply chains.
Community Feedback
Leave a Comment
Comments are reviewed before appearing. You will receive an email to verify before your comment appears.