PartsTable
Technical Data Sheet
Download PDF

3X1163SKVMG4-60AMPTDC12 — CIRCUIT BREAKER

✓ Government record, cited
— · MRO · MRO_GENERAL
PRODUCT OVERVIEW

3X1163SKVMG4-60AMPTDC12: CIRCUIT BREAKER.

The CIRCUIT BREAKER is a the manufacturer industrial component. Key specifications include material: PLASTIC CASE, body_style: MULTIPOLE-MULTIPLE ACTUATOR TYPE, body_width: 4.490 INCHES MINIMUM AND 4.510 INCHES MAXIMUM IN, body_height: 2.677 INCHES MINIMUM AND 2.697 INCHES MAXIMUM IN, body_length: 5.240 INCHES MINIMUM AND 5.260 INCHES MAXIMUM IN, boss_height: 0.208 INCHES MINIMUM AND 0.228 INCHES MAXIMUM IN. This part is cataloged in the U.S.

Government catalog under NSN 5925-00-800-1061, indicating validated use in U.S. government and defense logistics supply chains. Available through authorized enterprise resellers and TPM (Third Party Maintenance) channels.

Verify compatibility with your specific system configuration before ordering.

WHERE IT FITS
MRO→ MRO_GENERAL→ 3X1163SKVMG4-60AMPTDC12
NSN: 5925-00-800-1061
FSC: 5925 — Circuit Breakers
CAGE: 74193 — EATON CORP HEINEMANN PRODUCTS COMMERCIAL CONTROLS DIV (USA)
SPECIFICATIONS
materialPLASTIC CASE
body_styleMULTIPOLE-MULTIPLE ACTUATOR TYPE
body_width4.490 INCHES MINIMUM AND 4.510 INCHES MAXIMUM IN
body_height2.677 INCHES MINIMUM AND 2.697 INCHES MAXIMUM IN
body_length5.240 INCHES MINIMUM AND 5.260 INCHES MAXIMUM IN
boss_height0.208 INCHES MINIMUM AND 0.228 INCHES MAXIMUM IN
reset_methodMANUAL
storage_typeGENERAL PURPOSE WAREHOUSE
pole_quantity3
fragility_factorMODERATELY RUGGED
actuator_functionTRIP-RESET
frequency_in_hertz400.0 ALL LOCATIONS
NSN5925-00-800-1061
COMPONENT DIAGRAM
COMPONENT MAIN IC EDGE CONNECTOR No detailed specs available CIRCUIT BREAKER TITLE COMPONENT PN 3X1163SKVMG4-60AMPTDC12 MFR CIRCUIT BREAKER
KEY FEATURES
•
RESET METHOD: MANUAL
•
INTERNAL TRIP RELEASE CONFIGURATION: SERIES TRIP ALL LOCATIONS
•
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS: 416.0 AC ALL LOCATIONS
•
MOUNTING FACILITY TYPE AND QUANTITY: 12 THREADED HOLE(S) AND 12 UNTHREADED HOLE(S)
•
ACTUATOR POSITION DESIGNATION: AT EACH POLE
•
FREQUENCY IN HERTZ: 400.0 ALL LOCATIONS
•
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO WIDTH: 0.990 INCHES MINIMUM AND 1.010 INCHES MAXIMUM IN
•
FRAGILITY FACTOR: MODERATELY RUGGED
TECHNICAL CHARACTERISTICS
RESET METHODMANUAL
INTERNAL TRIP RELEASE CONFIGURATIONSERIES TRIP ALL LOCATIONS
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS416.0 AC ALL LOCATIONS
MOUNTING FACILITY TYPE AND QUANTITY12 THREADED HOLE(S) AND 12 UNTHREADED HOLE(S)
ACTUATOR POSITION DESIGNATIONAT EACH POLE
FREQUENCY IN HERTZ400.0 ALL LOCATIONS
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO WIDTH0.990 INCHES MINIMUM AND 1.010 INCHES MAXIMUM IN
FRAGILITY FACTORMODERATELY RUGGED
BODY STYLEMULTIPOLE-MULTIPLE ACTUATOR TYPE
ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT150.0 ALL LOCATIONS
SUBSTITUTES & CROSS-REFERENCES 1
64-184-1MG4-60-416-2-400Reference document
Same NSN cross-reference
Reference document — Secondary reference
LIFECYCLE
NSN statusActive· U.S. Government catalog
No demilitarization required
Ready to buy 3X1163SKVMG4-60AMPTDC12?
Compare prices from verified sellers on eBay
Buy on eBay →
As an eBay Partner, PartsTable may earn a commission. Your price is not affected.
FREQUENTLY ASKED QUESTIONS
What is 3X1163SKVMG4-60AMPTDC12?
3X1163SKVMG4-60AMPTDC12 is a CIRCUIT BREAKER. It is classified as a MRO (MRO_GENERAL).
What parts can replace 3X1163SKVMG4-60AMPTDC12?
There is 1 known substitute for 3X1163SKVMG4-60AMPTDC12: 64-184-1MG4-60-416-2-400. Substitute compatibility should be verified for your specific system.
What is the NSN for 3X1163SKVMG4-60AMPTDC12?
3X1163SKVMG4-60AMPTDC12 is cataloged in the U.S. Government catalog under NSN 5925-00-800-1061. This indicates validated use in U.S. government and defense supply chains.
Community Feedback
Leave a Comment
Comments are reviewed before appearing. You will receive an email to verify before your comment appears.

Request a Quote — 3X1163SKVMG4-60AMPTDC12