382S034-25S: INSULATION SLEEVING,ELECTRICAL,S.
INSULATION SLEEVING,ELECTRICAL,S. Key specifications include flexibility: RIGID, temp_rating: -75.0 CELSIUS AND 150.0 CELSIUS DEGC, style_designator: TRANSITION-Y, reliability_indicator: NOT ESTABLISHED, main_body_wall_thickness: 0.096 INCHES MINIMUM AND 0.144 INCHES MAXIMUM AFTER UNRESTRICTED RECOVERY IN, main_body_inside_diameter: 1.570 INCHES MINIMUM AS SUPPLIED IN. This part is cataloged in the U.S.
Government catalog under NSN 5970-01-514-2448, indicating validated use in U.S. government and defense logistics supply chains. Available through authorized enterprise resellers and TPM (Third Party Maintenance) channels.
Verify compatibility with your specific system configuration before ordering.
| flexibility | RIGID |
| temp_rating | -75.0 CELSIUS AND 150.0 CELSIUS DEGC |
| special_features | HEAT RECOVERABLE SCREEN, MAT'L IS FLUID-RESISTANT MODIFIED ELASTOMER; AGAVG1005-01-319-2649; WSD: HELICOPTER OBSERVATION (AHIP), OH-58D |
| style_designator | TRANSITION-Y |
| reliability_indicator | NOT ESTABLISHED |
| main_body_wall_thickness | 0.096 INCHES MINIMUM AND 0.144 INCHES MAXIMUM AFTER UNRESTRICTED RECOVERY IN |
| main_body_inside_diameter | 1.570 INCHES MINIMUM AS SUPPLIED IN |
| first_branch_wall_thickness | 0.080 INCHES MINIMUM AND 0.120 INCHES MAXIMUM AFTER UNRESTRICTED RECOVERY IN |
| first_branch_inside_diameter | 0.480 INCHES MAXIMUM AFTER UNRESTRICTED RECOVERY IN |
| second_branch_wall_thickness | 0.080 INCHES MINIMUM AND 0.120 INCHES MAXIMUM AFTER UNRESTRICTED RECOVERY IN |
| second_branch_inside_diameter | 0.480 INCHES MAXIMUM AFTER UNRESTRICTED RECOVERY IN |
| distance_from_edge_of_main_body_to_intersecting_centerlines | 2.600 INCHES NOMINAL AFTER UNRESTRICTED RECOVERY IN |
| NSN | 5970-01-514-2448 |
| DISTANCE FROM INTERSECTING CENTERLINE OF MAIN BODY TO END OF FIRST BRANCH | 3.230 INCHES NOMINAL AFTER UNRESTRICTED RECOVERY IN |
| TEMP RATING | -75.0 CELSIUS AND 150.0 CELSIUS DEGC |
| SECOND BRANCH INSIDE DIAMETER | 0.480 INCHES MAXIMUM AFTER UNRESTRICTED RECOVERY IN |
| SECOND BRANCH INSIDE DIAMETER | 0.910 INCHES MINIMUM AS SUPPLIED IN |
| STYLE DESIGNATOR | TRANSITION-Y |
| FLEXIBILITY | RIGID |
| ANGLE BETWEEN MAIN BODY AND SECOND BRANCH CENTERLINES IN DEG | 16.6 MINIMUM AND 18.4 MAXIMUM AFTER UNRESTRICTED RECOVERY |
| SECOND BRANCH WALL THICKNESS | 0.080 INCHES MINIMUM AND 0.120 INCHES MAXIMUM AFTER UNRESTRICTED RECOVERY IN |
| MAIN BODY INSIDE DIAMETER | 0.790 INCHES MAXIMUM AFTER UNRESTRICTED RECOVERY IN |
| MAIN BODY INSIDE DIAMETER | 1.570 INCHES MINIMUM AS SUPPLIED IN |
No substitute or cross-reference records for this part.