382A012-4/42: INSULATION SLEEVING,ELECTRICAL,S.
INSULATION SLEEVING,ELECTRICAL,S. Key specifications include material: PLASTIC POLYOLEFIN LOCATION NOT OTHERWISE SPECIFIED, flexibility: FLEXIBLE, main_body_wall_thickness: 0.060 INCHES NOMINAL AFTER UNRESTRICTED RECOVERY IN, main_body_inside_diameter: 0.520 INCHES MINIMUM AS SUPPLIED IN, first_branch_wall_thickness: 0.040 INCHES NOMINAL AFTER UNRESTRICTED RECOVERY IN, first_branch_inside_diameter: 0.130 INCHES MAXIMUM AFTER UNRESTRICTED RECOVERY IN. This part is cataloged in the U.S.
Government catalog under NSN 5970-01-334-4897, indicating validated use in U.S. government and defense logistics supply chains. Available through authorized enterprise resellers and TPM (Third Party Maintenance) channels.
Verify compatibility with your specific system configuration before ordering.
| material | PLASTIC POLYOLEFIN LOCATION NOT OTHERWISE SPECIFIED |
| flexibility | FLEXIBLE |
| main_body_wall_thickness | 0.060 INCHES NOMINAL AFTER UNRESTRICTED RECOVERY IN |
| main_body_inside_diameter | 0.520 INCHES MINIMUM AS SUPPLIED IN |
| first_branch_wall_thickness | 0.040 INCHES NOMINAL AFTER UNRESTRICTED RECOVERY IN |
| first_branch_inside_diameter | 0.130 INCHES MAXIMUM AFTER UNRESTRICTED RECOVERY IN |
| second_branch_wall_thickness | 0.040 INCHES NOMINAL AFTER UNRESTRICTED RECOVERY IN |
| second_branch_inside_diameter | 0.130 INCHES MAXIMUM AFTER UNRESTRICTED RECOVERY IN |
| distance_from_edge_of_main_body_to_intersecting_centerlines | 0.880 INCHES NOMINAL AFTER UNRESTRICTED RECOVERY IN |
| angle_between_main_body_and_second_branch_centerlines_in_deg | 22.500 MAXIMUM AFTER UNRESTRICTED RECOVERY |
| distance_from_intersecting_centerline_of_main_body_to_end_of_first_branch | 0.760 INCHES NOMINAL AFTER UNRESTRICTED RECOVERY IN |
| NSN | 5970-01-334-4897 |
| DISTANCE FROM INTERSECTING CENTERLINE OF MAIN BODY TO END OF FIRST BRANCH | 0.760 INCHES NOMINAL AFTER UNRESTRICTED RECOVERY IN |
| SECOND BRANCH INSIDE DIAMETER | 0.260 INCHES MINIMUM AS SUPPLIED IN |
| SECOND BRANCH INSIDE DIAMETER | 0.130 INCHES MAXIMUM AFTER UNRESTRICTED RECOVERY IN |
| FLEXIBILITY | FLEXIBLE |
| ANGLE BETWEEN MAIN BODY AND SECOND BRANCH CENTERLINES IN DEG | 10.000 MINIMUM AS SUPPLIED |
| ANGLE BETWEEN MAIN BODY AND SECOND BRANCH CENTERLINES IN DEG | 22.500 MAXIMUM AFTER UNRESTRICTED RECOVERY |
| SECOND BRANCH WALL THICKNESS | 0.040 INCHES NOMINAL AFTER UNRESTRICTED RECOVERY IN |
| MAIN BODY INSIDE DIAMETER | 0.240 INCHES MAXIMUM AFTER UNRESTRICTED RECOVERY IN |
| MAIN BODY INSIDE DIAMETER | 0.520 INCHES MINIMUM AS SUPPLIED IN |
| DISTANCE FROM EDGE OF MAIN BODY TO INTERSECTING CENTERLINES | 0.880 INCHES NOMINAL AFTER UNRESTRICTED RECOVERY IN |