PartsTable
Technical Data Sheet
382A ✓ Verified by PartsTable
· COMPONENT
WHAT YOU NEED TO KNOW
Verify manufacturer and server generation compatibility Check if Option PN or Spare PN — same part, different channel
Confirm exact part number — similar PNs may be different parts
PRODUCT OVERVIEW

OSCILLATOR,NONCRYSTAL CONTROLLED. Key specifications include material: STEEL OVERALL, overall_width: 0.6250 INCHES NOMINAL IN, outside_diameter: 3.8125 INCHES NOMINAL IN, style_designator: NORMAL ANGLE, backface_corner_radius: 0.0312 INCHES NOMINAL IN, calibration_accuracy_rating: 0.01 PERCENT VOLTAGE CALIBRATOR AND +/- 0.02 PERCENT CURRENT CALIBRATOR. This product is currently in active production with full OEM support.

This part is cataloged in the Federal Logistics Information System (FLIS) under NSN 6625-00-068-0609, indicating validated use in U.S. government and defense logistics supply chains. Available through authorized enterprise resellers and TPM (Third Party Maintenance) channels.

Verify compatibility with your specific system configuration before ordering.

WHERE IT FITS
382A
NSN: 6625-00-068-0609
FSC: 6625
CAGE: 89536 — FLUKE CORP (USA)
SPECIFICATIONS
materialSTEEL OVERALL
overall_width0.6250 INCHES NOMINAL IN
outside_diameter3.8125 INCHES NOMINAL IN
special_featuresMFG NAME: DC VOLTAGE/CURRENT CALIBRATOR; VOLTAGE AND CURRENT LIMITING ARE ADJUSTABLE; RESOLUTION 10 UV FOR VOLTAGE AND 0.1 UA FOR CURRENT WITH A STABILITY OF 0.005 PERCENT MO.
style_designatorNORMAL ANGLE
backface_corner_radius0.0312 INCHES NOMINAL IN
calibration_range_quantity6
calibration_accuracy_rating0.01 PERCENT VOLTAGE CALIBRATOR AND +/- 0.02 PERCENT CURRENT CALIBRATOR
instrument_calibration_rangeCURRENT MODE 0 TO 2 A IN 4 RANGES; VOLTAGE OUTPUT 0 TO 50 VDC AND 0 TO 5 VDC VDC
standard_tolerance_designationAFBMA CLASS 2
NSN6625-00-068-0609
COMPONENT DIAGRAM
COMPONENT MAIN IC EDGE CONNECTOR No detailed specs available OSCILLATOR,NONCRYSTAL CONTROLLED TITLE COMPONENT PN 382A MFR OSCILLATOR,NONCRYSTAL
KEY FEATURES
CALIBRATION RANGE QUANTITY: 6
INSTRUMENT CALIBRATION RANGE: CURRENT MODE 0 TO 2 A IN 4 RANGES; VOLTAGE OUTPUT 0 TO 50 VDC AND 0 TO 5 VDC VDC
CALIBRATION ACCURACY RATING: 0.01 PERCENT VOLTAGE CALIBRATOR AND +/- 0.02 PERCENT CURRENT CALIBRATOR
TECHNICAL CHARACTERISTICS (FLIS)
CALIBRATION RANGE QUANTITY6
INSTRUMENT CALIBRATION RANGECURRENT MODE 0 TO 2 A IN 4 RANGES; VOLTAGE OUTPUT 0 TO 50 VDC AND 0 TO 5 VDC VDC
CALIBRATION ACCURACY RATING0.01 PERCENT VOLTAGE CALIBRATOR AND +/- 0.02 PERCENT CURRENT CALIBRATOR
SPECIAL FEATURESMFG NAME: DC VOLTAGE/CURRENT CALIBRATOR; VOLTAGE AND CURRENT LIMITING ARE ADJUSTABLE; RESOLUTION 10 UV FOR VOLTAGE AND 0.1 UA FOR CURRENT WITH A STABILITY OF 0.005 PERCENT MO.
CALIBRATION RANGE QUANTITY6
INSTRUMENT CALIBRATION RANGECURRENT MODE 0 TO 2 A IN 4 RANGES; VOLTAGE OUTPUT 0 TO 50 VDC AND 0 TO 5 VDC VDC
CALIBRATION ACCURACY RATING0.01 PERCENT VOLTAGE CALIBRATOR AND +/- 0.02 PERCENT CURRENT CALIBRATOR
SPECIAL FEATURESMFG NAME: DC VOLTAGE/CURRENT CALIBRATOR; VOLTAGE AND CURRENT LIMITING ARE ADJUSTABLE; RESOLUTION 10 UV FOR VOLTAGE AND 0.1 UA FOR CURRENT WITH A STABILITY OF 0.005 PERCENT MO.
VERIFIED SUBSTITUTES & CROSS-REFERENCES 2
10A7292Interchangeable
interchangeable cross-reference
interchangeable
45733Interchangeable
interchangeable cross-reference
interchangeable
LIFECYCLE
StatusACTIVE
AvailabilityOEM and secondary market
RoHS CompliantEAR99ESD SensitiveNot HAZMAT
Ready to buy 382A?
Compare prices from verified sellers on eBay
Buy on eBay →
As an eBay Partner, PartsTable may earn a commission. Your price is not affected.
FREQUENTLY ASKED QUESTIONS
What is 382A?
382A is a OSCILLATOR,NONCRYSTAL CONTROLLED.
What parts can replace 382A?
There are 2 known substitutes for 382A: 10A7292, 45733. Substitute compatibility should be verified for your specific system.
What is the NSN for 382A?
382A is cataloged in the Federal Logistics Information System (FLIS) under NSN 6625-00-068-0609. This indicates validated use in U.S. government and defense supply chains.
Community Feedback
Comments (0)
No comments yet. Be the first to share what you know.
Leave a Comment
Comments are reviewed before appearing. You will receive an email to verify before your comment appears.

Request a Quote — 382A