PartsTable
Technical Data Sheet
36901 ✓ Verified by PartsTable
Cellularline · MRO · MRO_GENERAL
WHAT YOU NEED TO KNOW
Verify manufacturer and server generation compatibility Check if Option PN or Spare PN — same part, different channel
Confirm exact part number — similar PNs may be different parts
PRODUCT OVERVIEW

Adapter cable for connection of FireWire IEEE1934a (400Mbit/s) devices with 6 pin connector to a FireWire Controller with IEEE1394b (800Mbit/s) connector. Firewire800 Controller are downwardly compatible, therefore this cable provides connectivity for FireWire400 devices. This part is cataloged in the Federal Logistics Information System (FLIS) under NSN 5905-00-410-1313, indicating validated use in U.S.

government and defense logistics supply chains. Available through authorized enterprise resellers and TPM (Third Party Maintenance) channels. Verify compatibility with your specific system configuration before ordering.

WHERE IT FITS
MRO MRO_GENERAL 36901
NSN: 5905-00-410-1313
FSC: 5905
CAGE: 21461 — HALEAR INC DBA PRESTON SCIENTIFIC (USA)
SPECIFICATIONS
body_styleCYLINDRICAL
duty_cycleINTERMITTENT
body_length0.250 INCHES NOMINAL IN
temp_rating-20.0 AMBIENT CELSIUS AND 65.0 AMBIENT CELSIUS
power_rating0.0330 HORSEPOWER OUTPUT
winding_typeSERIES WOUND
actuator_typeFLUSH DRIVE WITH SLOT-HOLE
body_diameter0.250 INCHES NOMINAL IN
overall_width1.562 INCHES IN
time_interval2.0 MINUTES MAXIMUM ON AND 18.0 MINUTES MINIMUM OFF
cooling_methodNONVENTILATED
overall_height2.062 INCHES IN
NSN5905-00-410-1313
COMPONENT DIAGRAM
COMPONENT MAIN IC EDGE CONNECTOR MFR: Cellularline RESISTOR,VARIABLE,WIRE WOUND,NON TITLE COMPONENT PN 36901 MFR Cellularline RESISTOR,VARIABLE,WIRE
KEY FEATURES
CENTER TO CENTER DISTANCE BETWEEN TERMINALS: 0.100 INCHES NOMINAL IN
ROTARY ACTUATOR TRAVEL IN ANGULAR DEG: 270.0 NOMINAL
CENTER TO CENTER DISTANCE BETWEEN TERMINAL ROWS: 0.100 INCHES NOMINAL IN
CENTER TO CENTER DISTANCE BETWEEN CENTER TERMINAL AND OUTSIDE TERMINAL: 0.100 INCHES NOMINAL IN
POWER DISSIPATION RATING PER SECTION IN WATTS: 0.5 FREE AIR SINGLE SECTION
MOUNTING METHOD: TERMINAL
AMBIENT TEMP IN DEG CELSIUS PER SECTION AT FULL RATED POWER: 70.0 SINGLE SECTION
TERMINAL LOCATION: LOWER ADJACENT SIDE TWO ROWS LOCATION NOT OTHERWISE SPECIFIED
TECHNICAL CHARACTERISTICS (FLIS)
CENTER TO CENTER DISTANCE BETWEEN TERMINALS0.100 INCHES NOMINAL IN
ROTARY ACTUATOR TRAVEL IN ANGULAR DEG270.0 NOMINAL
CENTER TO CENTER DISTANCE BETWEEN TERMINAL ROWS0.100 INCHES NOMINAL IN
CENTER TO CENTER DISTANCE BETWEEN CENTER TERMINAL AND OUTSIDE TERMINAL0.100 INCHES NOMINAL IN
POWER DISSIPATION RATING PER SECTION IN WATTS0.5 FREE AIR SINGLE SECTION
MOUNTING METHODTERMINAL
AMBIENT TEMP IN DEG CELSIUS PER SECTION AT FULL RATED POWER70.0 SINGLE SECTION
TERMINAL LOCATIONLOWER ADJACENT SIDE TWO ROWS LOCATION NOT OTHERWISE SPECIFIED
RESISTANCE TOLERANCE PER SECTION IN PERCENT-10.0 TO 20.0 SINGLE SECTION
TEMP COEFFICIENT OF RESISTANCE PER SECTION IN PPM PER DEG CELSIUS-250.0 TO 250.0 SINGLE SECTION
VERIFIED SUBSTITUTES & CROSS-REFERENCES 7
369AInterchangeable
interchangeable cross-reference
interchangeable
36901Interchangeable
interchangeable cross-reference
interchangeable
NL82715-1Interchangeable
interchangeable cross-reference
interchangeable
50204-5031-95Interchangeable
Same NIIN cross-reference
interchangeable
5010097-012Interchangeable
Same NIIN cross-reference
interchangeable
2100-2031Interchangeable
Same NIIN cross-reference
interchangeable
LIFECYCLE
StatusCANCELLED
Availability
RoHS CompliantEAR99Not HAZMAT
Ready to buy 36901?
Compare prices from verified sellers on eBay
Buy on eBay →
As an eBay Partner, PartsTable may earn a commission. Your price is not affected.
FREQUENTLY ASKED QUESTIONS
What is 36901?
36901 is a RESISTOR,VARIABLE,WIRE WOUND,NON manufactured by Cellularline. It is classified as a MRO (MRO_GENERAL).
What parts can replace 36901?
There are 7 known substitutes for 36901: 369A, 36901, NL82715-1 and 4 more. Substitute compatibility should be verified for your specific system.
Is 36901 still available?
36901 is currently cancelled.
Community Feedback
Comments (0)
No comments yet. Be the first to share what you know.
Leave a Comment
Comments are reviewed before appearing. You will receive an email to verify before your comment appears.

Request a Quote — 36901