The Generating and Charging Plant,ox, cataloged under National Stock Number 3655-01-605-9876, is classified within Federal Supply Class 3655 (Gas Generating and Dispensing Systems, Fixed or Mobile) of the Special Industry Machinery group. Government technical data includes 3 specifications, cited from the U.S. Government catalog. 3 additional reference documents (drawings, advisory and superseded references) are recorded in the U.S. Government catalog. Current acquisition status: Active.
| Parameter | Value |
|---|---|
| NSN | 3655-01-605-9876 |
| Item Name | Generating and Charging Plant,ox |
| FSC / FSG | 3655 / 36 — Gas Generating and Dispensing Systems, Fixed or Mobile |
| Status | ACTIVE |
| Voltage in Volts and Current Type | 208.0 AC |
| Fragility Factor | RUGGED |
| Storage Temp Range | -40.0 TO 140.0 FAHRENHEIT DEGF |
| Acquisition Status | ACTIVE |
| DEMIL Code | DEMIL A — No Demilitarization Required |
| Hazard | Possible hazard — SDS may be required (DLA HMIC P) |
| Criticality Code | X |
| Reference | Meaning |
|---|---|
| MC-045-000P-00 | 3/2 Design control — primary reference U.S. Government activity |
| 26854 | 5/1 Secondary reference U.S. Government activity |
| 6515NCM116807 | 5/1 Secondary reference Defense Medical Standardization Board |
NSN 3655-01-605-9876 is a Generating and Charging Plant,ox, classified under FSC 3655, Gas Generating and Dispensing Systems, Fixed or Mobile. Status: active.
Key specifications for 3655-01-605-9876: Voltage in Volts and Current Type: 208.0 AC; Fragility Factor: RUGGED; Storage Temp Range: -40.0 TO 140.0 FAHRENHEIT DEGF; Special Features: OXYGEN GENERATION SYSTEM, DEPLOYABLE, MEDIUM; POINT OF USE OXYGEN GENERATION SYSTEM; NOMINAL SIZE: 60 X 76 X 28 IN; WEIGHT: 2250 LBS; OXYGEN PURITY: 93 +/- 3% OXYGEN BY VOLUME; OXYGEN FLOW (OXY 93%): 120 L/MIN; OUTPUT PRESSURE: LOW PRESSURE PORT ADJUSTABLE FROM 50 TO 100 PSIG, HIGH PRESSURE PORT 2250 PSIG; POWER CONSUMPTION: 9.6 KW AVERAGE; ELECTRICAL POWER EQUIPMENT: 208 VAC, 50/60 HZ, 3 PHASE WYE CONNECTION; STORAGE TEMPERATURE: -40 TO +140 DEG F; OPERATION TEMPERATURE: -25 TO +120 DEG F VAC. 3 specifications are documented in the U.S. Government catalog.
Possible hazard — SDS may be required (DLA HMIC P). Hazard information on this page is shown exactly as it appears in the DLA record.
U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-16.