PartsTable
Technical Data Sheet
Download PDF

34100009-1 — EXTINGUISHER,FIRE

✓ Government record, cited
— · COMPONENT
PRODUCT OVERVIEW

34100009-1: EXTINGUISHER,FIRE.

The EXTINGUISHER,FIRE is a the manufacturer industrial component. Key specifications include unit_type: CHARGED, design_type: AUTOMATIC AND STANDARD, cylinder_type: SHATTERPROOF, capacity_rating: 4.58 KILOGRAMS MINIMUM AND 4.63 KILOGRAMS MAXIMUM KG, charge_design_type: STANDARD, extinguishing_agent_for_which_designed: BROMOTRIFLUOROMETHANE. This part is cataloged in the U.S.

Government catalog under NSN 4210-01-701-4443, indicating validated use in U.S. government and defense logistics supply chains. Available through authorized enterprise resellers and TPM (Third Party Maintenance) channels.

Verify compatibility with your specific system configuration before ordering.

WHERE IT FITS
34100009-1
NSN: 4210-01-701-4443
FSC: 4210 — Firefighting Equipment
CAGE: 05167 — MEGGITT SAFETY SYSTEMS INC (USA)
SPECIFICATIONS
unit_typeCHARGED
design_typeAUTOMATIC AND STANDARD
cylinder_typeSHATTERPROOF
capacity_rating4.58 KILOGRAMS MINIMUM AND 4.63 KILOGRAMS MAXIMUM KG
charge_design_typeSTANDARD
extinguishing_agent_for_which_designedBROMOTRIFLUOROMETHANE
part_name_assigned_by_controlling_agencyFIRE EXTINGUISHER
NSN4210-01-701-4443
COMPONENT DIAGRAM
COMPONENT MAIN IC EDGE CONNECTOR No detailed specs available EXTINGUISHER,FIRE TITLE COMPONENT PN 34100009-1 MFR EXTINGUISHER,FIRE
KEY FEATURES
•
EXTINGUISHING AGENT DISCHARGE METHOD: CARTRIDGE
•
DESIGN TYPE: AUTOMATIC AND STANDARD
•
CHARGE DESIGN TYPE: STANDARD
•
CAPACITY RATING: 4.58 KILOGRAMS MINIMUM AND 4.63 KILOGRAMS MAXIMUM KG
•
UNIT TYPE: CHARGED
•
EXTINGUISHING AGENT FOR WHICH DESIGNED: BROMOTRIFLUOROMETHANE
•
CYLINDER TYPE: SHATTERPROOF
TECHNICAL CHARACTERISTICS
EXTINGUISHING AGENT DISCHARGE METHODCARTRIDGE
DESIGN TYPEAUTOMATIC AND STANDARD
CHARGE DESIGN TYPESTANDARD
CAPACITY RATING4.58 KILOGRAMS MINIMUM AND 4.63 KILOGRAMS MAXIMUM KG
UNIT TYPECHARGED
SPECIAL FEATURESEXTINGUISHING AGENT: BROMOTRIFLUOROMETHANE (CBRF3, HALON) (PER ASTM D5632, TYPE 2). PRESSURIZING GAS: NITROGEN. PRESSURE DATA AT 21 C: 800 TO 825 PSIG (5516 TO 5688 KPAG). AMBIENT TEMPERATURE RANGE: -55 C TO +85 C. EXTINGUISHING AGENT (FULL CHARGE) 4.58 TO 4.63 KG. NITROGEN CHARGE: 0.28 KG MAXIMUM. CHARGED FIRE EXTINGUISHER WEIGHT: 10.38 KG MAXIMUM. CARTRIDGE VOLTAGE DATA: 18 TO 36 VDC. CARTRIDGE CURRENT NO FIRE: 1.0 AMPERE MINIMUM FOR FIVE MINUTES CARTRIDGE WATTAGE NO FIRE: 1.0 WATT MINIMUM FOR FIVE MINUTES. PRESSURE SWITCH MAXIMUM CURRENT: 1.0 AMPERE. PRESSURE SWITCH SWITCHING VOLTAGE: 1000 VDC. 34100009-2: 10.38 KG MAXIMUM. VDC
EXTINGUISHING AGENT FOR WHICH DESIGNEDBROMOTRIFLUOROMETHANE
CYLINDER TYPESHATTERPROOF
PART NAME ASSIGNED BY CONTROLLING AGENCYFIRE EXTINGUISHER
OTHER ITEMS IN FSC 4210 — Firefighting Equipment
Items in the same Federal Supply class. No interchangeability or substitution relationship is implied.
4210-00-001-3525 4210-00-001-3526 4210-00-003-6976 4210-00-004-8316 4210-00-005-1080 4210-00-005-7152 4210-00-005-7684 4210-00-006-6244
SUBSTITUTES & CROSS-REFERENCES 1
26-22-92 REV 1Reference document
Same NSN cross-reference
Reference document — Drawing number reference only
LIFECYCLE
NSN statusActive· U.S. Government catalog
No demilitarization required
Ready to buy 34100009-1?
Compare prices from verified sellers on eBay
Buy on eBay →
As an eBay Partner, PartsTable may earn a commission. Your price is not affected.
FREQUENTLY ASKED QUESTIONS
What is 34100009-1?
34100009-1 is a EXTINGUISHER,FIRE.
What parts can replace 34100009-1?
There is 1 known substitute for 34100009-1: 26-22-92 REV 1. Substitute compatibility should be verified for your specific system.
What is the NSN for 34100009-1?
34100009-1 is cataloged in the U.S. Government catalog under NSN 4210-01-701-4443. This indicates validated use in U.S. government and defense supply chains.
Community Feedback