308242-1: TRANSFORMER,POWER.
The TRANSFORMER,POWER is a the manufacturer industrial component. Key specifications include body_height: 0.440 INCHES MINIMUM AND 0.460 INCHES MAXIMUM IN, overall_width: 0.865 INCHES MINIMUM AND 0.885 INCHES MAXIMUM IN, inclosure_type: FULLY INCLOSED, overall_height: 1.500 INCHES MINIMUM IN, overall_length: 0.865 INCHES MINIMUM AND 0.885 INCHES MAXIMUM IN, special_features: WEAPON SYSTEM ESSENTIAL; DRAWING NAME: TRANSFORMER, FLYBACK. This part is cataloged in the U.S.
Government catalog under NSN 5950-01-461-4831, indicating validated use in U.S. government and defense logistics supply chains. Available through authorized enterprise resellers and TPM (Third Party Maintenance) channels.
Verify compatibility with your specific system configuration before ordering.
| body_height | 0.440 INCHES MINIMUM AND 0.460 INCHES MAXIMUM IN |
| overall_width | 0.865 INCHES MINIMUM AND 0.885 INCHES MAXIMUM IN |
| inclosure_type | FULLY INCLOSED |
| overall_height | 1.500 INCHES MINIMUM IN |
| overall_length | 0.865 INCHES MINIMUM AND 0.885 INCHES MAXIMUM IN |
| special_features | WEAPON SYSTEM ESSENTIAL; DRAWING NAME: TRANSFORMER, FLYBACK |
| reliability_indicator | NOT ESTABLISHED |
| maximum_operating_temp | 90.0 CELSIUS DEGC |
| end_item_identification | WSD: AIRCRAFT, EAGLE F-15; NEXT ASSEMBLY 93106842 USED ON ARC-164 |
| winding_operating_current | 0.550 AMPERES DC NOMINAL SINGLE COMPONENT SECOND WINDING |
| terminal_type_and_quantity | 12 WIRE LEAD |
| criticality_code_justification | FEAT |
| NSN | 5950-01-461-4831 |
| OVERALL HEIGHT | 1.500 INCHES MINIMUM IN |
| INCLOSURE TYPE | FULLY INCLOSED |
| INPUT-OUTPUT PHASE RELATIONSHIP | SINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT |
| BODY HEIGHT | 0.440 INCHES MINIMUM AND 0.460 INCHES MAXIMUM IN |
| CRITICALITY CODE JUSTIFICATION | FEAT |
| OVERALL LENGTH | 0.865 INCHES MINIMUM AND 0.885 INCHES MAXIMUM IN |
| OVERALL WIDTH | 0.865 INCHES MINIMUM AND 0.885 INCHES MAXIMUM IN |
| MAXIMUM OPERATING TEMP | 90.0 CELSIUS DEGC |
| WINDING OPERATING CURRENT | 0.010 AMPERES DC NOMINAL SINGLE COMPONENT SIXTH WINDING |
| WINDING OPERATING CURRENT | 0.027 AMPERES DC NOMINAL SINGLE COMPONENT FIFTH WINDING |