WHAT YOU NEED TO KNOW
Stranded for flexible routing, solid for conduit THHN/THWN dual-rated — check both tables
Ampacity depends on installation method
PRODUCT OVERVIEW

The 3008-566 is a the manufacturer industrial component. Key specifications include color: BLACK FIRST POSITION JACKET CABLE, material: PLASTIC POLYVINYL CHLORIDE (PVC) FIRST POSITION PRIMARY INSULATION ALL CONDUCTORS, temp_rating: -40.0 CELSIUS AND 105.0 CELSIUS DEGC, conductor_form: STRANDED ALL CONDUCTORS, voltage_rating: 600.0 MAXIMUM ROOT MEAN SQUARE (RMS) OPERATING VOLTAGE ALL CONDUCTORS, surface_treatment: TIN CORE CONDUCTOR ALL CONDUCTORS. This product is currently in active production with full OEM support.

This part is cataloged in the Federal Logistics Information System (FLIS) under NSN 6145-01-224-2452, indicating validated use in U.S. government and defense logistics supply chains. Available through authorized enterprise resellers and TPM (Third Party Maintenance) channels.

Verify compatibility with your specific system configuration before ordering.

WHERE IT FITS
MRO MRO_GENERAL 3008-566
NSN: 6145-01-224-2452
FSC: 6145
CAGE: 05869 — RAYTHEON COMPANY DIV RMD STRATEGIC (USA)
SPECIFICATIONS
colorBLACK FIRST POSITION JACKET CABLE
materialPLASTIC POLYVINYL CHLORIDE (PVC) FIRST POSITION PRIMARY INSULATION ALL CONDUCTORS
temp_rating-40.0 CELSIUS AND 105.0 CELSIUS DEGC
conductor_formSTRANDED ALL CONDUCTORS
voltage_rating600.0 MAXIMUM ROOT MEAN SQUARE (RMS) OPERATING VOLTAGE ALL CONDUCTORS
surface_treatmentTIN CORE CONDUCTOR ALL CONDUCTORS
conductor_quantity120
round_conductor_size22 AWG ALL CONDUCTORS
cross-sectional_shape_styleROUND
strand_awg_size_per_conductor30 ALL CONDUCTORS
strand_quantity_per_conductor7 ALL CONDUCTORS
cross_section_outside_diameter0.930 INCHES NOMINAL IN
NSN6145-01-224-2452
COMPONENT DIAGRAM
WIRE / CABLE — AMPACITY DEPENDS ON INSTALLATION CROSS-SECTION JACKET WIRE SPECIFICATIONS Conductor Size: — Conductor Count: — Voltage Rating: — Insulation: — Temp Rating: — PN: 3008-566 · OEM ⚠ VERIFY BEFORE ORDERING Ampacity depends on installation method — conduit ≠ free air ≠ underground. Same wire, different ratings. AWG sizing is inverse — smaller number = thicker wire (4 AWG > 12 AWG) ✓ BROKER TIP Stranded = flexible routing and vibration resistance. Solid = fixed conduit runs only. THHN/THWN = dual rated — check both dry and wet ampacity tables PARTSTABLE TECHNICAL DRAWING — NOT TO SCALE
KEY FEATURES
SURFACE TREATMENT DOCUMENT AND CLASSIFICATION: ASTM B33-63 ASSN STD SINGLE TREATMENT RESPONSE CORE CONDUCTOR ALL CONDUCTORS
MATERIAL DOCUMENT AND CLASSIFICATION: ASTM B33 ASSN STD ALL MATERIAL RESPONSES CORE CONDUCTOR ALL CONDUCTORS
VOLTAGE RATING: 600.0 MAXIMUM ROOT MEAN SQUARE (RMS) OPERATING VOLTAGE ALL CONDUCTORS
MATERIAL: COPPER ALLOY 101 OR COPPER ALLOY 102 CORE CONDUCTOR ALL CONDUCTORS
CROSS SECTION OUTSIDE DIAMETER: 0.930 INCHES NOMINAL IN
CONDUCTOR QUANTITY: 120
COLOR CODING DOCUMENT: 3008-05869 DRAWING (THIS IS THE BASIC GOVERNING DRAWING, SUCH AS A CONTRACTOR DRAWING, ORIGINAL EQUIPMENT MANUFACTURER DRAWING, ETC.; EXCLUDES ANY SPECIFICATION, STANDARD OR OTHER DOCUMENT THAT MAY BE REFERENCED IN A BASIC GOVERNING DRAWING)
SURFACE TREATMENT: TIN CORE CONDUCTOR ALL CONDUCTORS
TECHNICAL CHARACTERISTICS (FLIS)
SURFACE TREATMENT DOCUMENT AND CLASSIFICATIONASTM B33-63 ASSN STD SINGLE TREATMENT RESPONSE CORE CONDUCTOR ALL CONDUCTORS
MATERIAL DOCUMENT AND CLASSIFICATIONASTM B33 ASSN STD ALL MATERIAL RESPONSES CORE CONDUCTOR ALL CONDUCTORS
VOLTAGE RATING600.0 MAXIMUM ROOT MEAN SQUARE (RMS) OPERATING VOLTAGE ALL CONDUCTORS
MATERIALCOPPER ALLOY 101 OR COPPER ALLOY 102 CORE CONDUCTOR ALL CONDUCTORS
CROSS SECTION OUTSIDE DIAMETER0.930 INCHES NOMINAL IN
CONDUCTOR QUANTITY120
COLOR CODING DOCUMENT3008-05869 DRAWING (THIS IS THE BASIC GOVERNING DRAWING, SUCH AS A CONTRACTOR DRAWING, ORIGINAL EQUIPMENT MANUFACTURER DRAWING, ETC.; EXCLUDES ANY SPECIFICATION, STANDARD OR OTHER DOCUMENT THAT MAY BE REFERENCED IN A BASIC GOVERNING DRAWING)
SURFACE TREATMENTTIN CORE CONDUCTOR ALL CONDUCTORS
ROUND CONDUCTOR SIZE22 AWG ALL CONDUCTORS
STRAND AWG SIZE PER CONDUCTOR30 ALL CONDUCTORS
VERIFIED SUBSTITUTES & CROSS-REFERENCES 17
52-48Upgraded Successor
successor cross-reference
successor
9987610Upgraded Successor
successor cross-reference
successor
5248UInterchangeable
interchangeable cross-reference
interchangeable
01-93-011Interchangeable
interchangeable cross-reference
interchangeable
10098AInterchangeable
interchangeable cross-reference
interchangeable
372-0223Interchangeable
interchangeable cross-reference
interchangeable
LIFECYCLE
StatusACTIVE
AvailabilityOEM and secondary market
RoHS CompliantEAR99Not HAZMAT
Ready to buy 3008-566?
Compare prices from verified sellers on eBay
Buy on eBay →
As an eBay Partner, PartsTable may earn a commission. Your price is not affected.
FREQUENTLY ASKED QUESTIONS
What is 3008-566?
3008-566 is a 3008-566. It is classified as a MRO (MRO_GENERAL).
What parts can replace 3008-566?
There are 17 known substitutes for 3008-566: 52-48, 9987610, 5248U and 14 more. Substitute compatibility should be verified for your specific system.
What is the NSN for 3008-566?
3008-566 is cataloged in the Federal Logistics Information System (FLIS) under NSN 6145-01-224-2452. This indicates validated use in U.S. government and defense supply chains.
Community Feedback
Comments (0)
No comments yet. Be the first to share what you know.
Leave a Comment
Comments are reviewed before appearing. You will receive an email to verify before your comment appears.

Request a Quote — 3008-566