PartsTable
Technical Data Sheet
30060-1 ✓ Verified by PartsTable
· MRO · MRO_GENERAL
WHAT YOU NEED TO KNOW
Verify manufacturer and server generation compatibility Check if Option PN or Spare PN — same part, different channel
Confirm exact part number — similar PNs may be different parts
PRODUCT OVERVIEW

CAPACITOR,FIXED,PLASTIC DIELECTR. Key specifications include shape: TEARDROP, bearings: NOT INCLUDED, material: STEEL COMP 304 OVERALL, bore_type: STRAIGHT, body_style: W/O MTG FACILITIES, AXIAL TERMINALS, face_width: 2.000 INCHES NOMINAL IN. This part is cataloged in the Federal Logistics Information System (FLIS) under NSN 5910-00-566-4127, indicating validated use in U.S.

government and defense logistics supply chains. Available through authorized enterprise resellers and TPM (Third Party Maintenance) channels. Verify compatibility with your specific system configuration before ordering.

WHERE IT FITS
MRO MRO_GENERAL 30060-1
NSN: 5910-00-566-4127
FSC: 5910
CAGE: 06141 — L3 AVIATION PRODUCTS, INC. DBA L3 TECHNOLOGIES (USA)
SPECIFICATIONS
shapeTEARDROP
bearingsNOT INCLUDED
materialSTEEL COMP 304 OVERALL
quantity1
bore_typeSTRAIGHT
body_styleW/O MTG FACILITIES, AXIAL TERMINALS
face_width2.000 INCHES NOMINAL IN
body_length1.438 INCHES NOMINAL IN
bore_length1.904 INCHES NOMINAL IN
design_formWEBBED
bore_featureINCLUDED
corner_shapeSQUARE OUTSIDE RIGHT CORNER
NSN5910-00-566-4127
COMPONENT DIAGRAM
COMPONENT MAIN IC EDGE CONNECTOR No detailed specs available CAPACITOR,FIXED,PLASTIC DIELECTR TITLE COMPONENT PN 30060-1 MFR CAPACITOR,FIXED,PLASTI
KEY FEATURES
RELIABILITY INDICATOR: NOT ESTABLISHED
BODY STYLE: W/O MTG FACILITIES, AXIAL TERMINALS
FEATURES PROVIDED: HERMETICALLY SEALED CASE
DISSIPATION FACTOR AT REFERENCE TEMP IN PERCENT: 1.0000
CASE INSULATION MATERIAL: PLASTIC
TERMINAL TYPE AND QUANTITY: 2 UNINSULATED WIRE LEAD
INSULATION RESISTANCE AT REFERENCE TEMP: 25000.0 MEGOHMS
SPECIFICATION/STANDARD DATA: 81349-MIL-C-19978/16 GOVERNMENT SPECIFICATION
TYPICAL APPLICATIONS
  • RAID cache protection during power loss events
  • Write-back cache enablement for storage controllers
  • Enterprise server data integrity assurance
  • Hot-swap battery/capacitor replacement in production
TECHNICAL CHARACTERISTICS (FLIS)
RELIABILITY INDICATORNOT ESTABLISHED
BODY STYLEW/O MTG FACILITIES, AXIAL TERMINALS
FEATURES PROVIDEDHERMETICALLY SEALED CASE
DISSIPATION FACTOR AT REFERENCE TEMP IN PERCENT1.0000
CASE INSULATION MATERIALPLASTIC
TERMINAL TYPE AND QUANTITY2 UNINSULATED WIRE LEAD
INSULATION RESISTANCE AT REFERENCE TEMP25000.0 MEGOHMS
SPECIFICATION/STANDARD DATA81349-MIL-C-19978/16 GOVERNMENT SPECIFICATION
TEST DATA DOCUMENT81349-MIL-C-19978 SPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS, BROCHURES,ETC., THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS, INDUSTRY DIRECTORIES, AND SIMILAR TRADE PUBLICATIONS, REFLECTING GENERAL TYPE DATA ON CERTAIN ENVIRONMENTAL AND PERFORMANCE REQUIREMENTS AND TEST CONDITIONS THAT ARE SHOWN AS "TYPICAL", "AVERAGE", "NOMINAL", ETC.).
NONDERATED CONTINUOUS VOLTAGE RATING AND TYPE PER SECTION600.0 DC SINGLE SECTION
VERIFIED SUBSTITUTES & CROSS-REFERENCES 12
21185Interchangeable
interchangeable cross-reference
interchangeable
30060-1Interchangeable
interchangeable cross-reference
interchangeable
4178765Interchangeable
interchangeable cross-reference
interchangeable
CP09A1KF104K3Interchangeable
interchangeable cross-reference
interchangeable
F102Interchangeable
interchangeable cross-reference
interchangeable
P688Interchangeable
interchangeable cross-reference
interchangeable
LIFECYCLE
StatusCANCELLED
Availability
RoHS CompliantEAR99Not HAZMAT
Ready to buy 30060-1?
Compare prices from verified sellers on eBay
Buy on eBay →
As an eBay Partner, PartsTable may earn a commission. Your price is not affected.
FREQUENTLY ASKED QUESTIONS
What is 30060-1?
30060-1 is a CAPACITOR,FIXED,PLASTIC DIELECTR. It is classified as a MRO (MRO_GENERAL).
What parts can replace 30060-1?
There are 12 known substitutes for 30060-1: 21185, 30060-1, 4178765 and 9 more. Substitute compatibility should be verified for your specific system.
Is 30060-1 still available?
30060-1 is currently cancelled.
Community Feedback
Comments (0)
No comments yet. Be the first to share what you know.
Leave a Comment
Comments are reviewed before appearing. You will receive an email to verify before your comment appears.