30055-50 — CIRCUIT BREAKER

✓ Government record, cited
— · MRO · MRO_GENERAL
PRODUCT OVERVIEW

30055-50: CIRCUIT BREAKER.

The CIRCUIT BREAKER is a the manufacturer industrial component. Key specifications include body_style: SINGLE POLE TYPE, body_width: 15.8 MILLIMETERS NOMINAL MM, reset_method: AUTOMATIC, overall_length: 50.8 MILLIMETERS NOMINAL MM, trip_release_method: MAGNETIC SINGLE LOCATION, circuit_protection_type: OVERCURRENT SINGLE LOCATION. This part is cataloged in the U.S.

Government catalog under NSN 5925-01-363-3239, indicating validated use in U.S. government and defense logistics supply chains. Available through authorized enterprise resellers and TPM (Third Party Maintenance) channels.

Verify compatibility with your specific system configuration before ordering.

WHERE IT FITS
MRO→ MRO_GENERAL→ 30055-50
NSN: 5925-01-363-3239
FSC: 5925 — Circuit Breakers
CAGE: 13445 — COLE HERSEE COMPANY (USA)
SPECIFICATIONS
body_styleSINGLE POLE TYPE
body_width15.8 MILLIMETERS NOMINAL MM
reset_methodAUTOMATIC
pole_quantity1
overall_length50.8 MILLIMETERS NOMINAL MM
trip_release_methodMAGNETIC SINGLE LOCATION
circuit_protection_typeOVERCURRENT SINGLE LOCATION
terminal_type_and_quantity2 THREADED STUD
trip_release_characteristicINSTANTANEOUS SINGLE LOCATION
unthreaded_mounting_hole_diameter5.6 MILLIMETERS NOMINAL MM
internal_trip_release_configurationSERIES TRIP SINGLE LOCATION
mounting_facility_type_and_quantity2 UNTHREADED HOLE(S)
NSN5925-01-363-3239
COMPONENT DIAGRAM
COMPONENT MAIN IC EDGE CONNECTOR No detailed specs available CIRCUIT BREAKER TITLE COMPONENT PN 30055-50 MFR CIRCUIT BREAKER
KEY FEATURES
•
RESET METHOD: AUTOMATIC
•
INTERNAL TRIP RELEASE CONFIGURATION: SERIES TRIP SINGLE LOCATION
•
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS: 12.0 DC SINGLE LOCATION
•
MOUNTING FACILITY TYPE AND QUANTITY: 2 UNTHREADED HOLE(S)
•
BODY STYLE: SINGLE POLE TYPE
•
ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT: 125.0 SINGLE LOCATION
•
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH: 39.6 MILLIMETERS NOMINAL MM
•
CIRCUIT PROTECTION TYPE: OVERCURRENT SINGLE LOCATION
TECHNICAL CHARACTERISTICS
RESET METHODAUTOMATIC
INTERNAL TRIP RELEASE CONFIGURATIONSERIES TRIP SINGLE LOCATION
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS12.0 DC SINGLE LOCATION
MOUNTING FACILITY TYPE AND QUANTITY2 UNTHREADED HOLE(S)
BODY STYLESINGLE POLE TYPE
ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT125.0 SINGLE LOCATION
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH39.6 MILLIMETERS NOMINAL MM
CIRCUIT PROTECTION TYPEOVERCURRENT SINGLE LOCATION
BODY WIDTH15.8 MILLIMETERS NOMINAL MM
UNTHREADED MOUNTING HOLE DIAMETER5.6 MILLIMETERS NOMINAL MM
OTHER ITEMS IN FSC 5925 — Circuit Breakers
Items in the same Federal Supply class. No interchangeability or substitution relationship is implied.
5925-00-001-1277 5925-00-001-2809 5925-00-001-3838 5925-00-001-5748 5925-00-001-5926 5925-00-001-5938 5925-00-001-5942 5925-00-001-5977
SUBSTITUTES & CROSS-REFERENCES

No substitute or cross-reference records for this part.

LIFECYCLE
NSN statusActive· U.S. Government catalog
Acquisition advice: Normally procured from the manufacturer (OEM)No demilitarization required
Ready to buy 30055-50?
Compare prices from verified sellers on eBay
Buy on eBay →
As an eBay Partner, PartsTable may earn a commission. Your price is not affected.
FREQUENTLY ASKED QUESTIONS
What is 30055-50?
30055-50 is a CIRCUIT BREAKER. It is classified as a MRO (MRO_GENERAL).
What is the NSN for 30055-50?
30055-50 is cataloged in the U.S. Government catalog under NSN 5925-01-363-3239. This indicates validated use in U.S. government and defense supply chains.