2755000: TEST STATION,FUEL CONTROL SYSTEM.
TEST STATION,FUEL CONTROL SYSTEM. Key specifications include functional_description: USED FOR FAULT ISOLATION,AND FINAL SERVICE ACCEPTANCE ON ASSEMBLIES/SUB-ASSEMBLIES OF THE AUGMENTOR PUMP CONTROLLER, end_item_identification: F100-PW-220 ACFT ENGINE, reference_data_and_literature: SERD NO. 4802.
This part is cataloged in the U.S. Government catalog under NSN 4920-01-218-4171, indicating validated use in U.S. government and defense logistics supply chains.
Available through authorized enterprise resellers and TPM (Third Party Maintenance) channels. Verify compatibility with your specific system configuration before ordering.
| functional_description | USED FOR FAULT ISOLATION,AND FINAL SERVICE ACCEPTANCE ON ASSEMBLIES/SUB-ASSEMBLIES OF THE AUGMENTOR PUMP CONTROLLER |
| end_item_identification | F100-PW-220 ACFT ENGINE |
| reference_data_and_literature | SERD NO. 4802 |
| NSN | 4920-01-218-4171 |
| REFERENCE DATA AND LITERATURE | SERD NO. 4802 |
| SPECIAL FEATURES | 480.0 VAC,60.0 HZ,3-PHASE,9.5 KVA; OUTPUT/OPERATING CHARACTERISTICS: FUEL: 0-1400 PSIG,0-36 GPM,85 DEG F PORM 2 DEG; PNEUMATIC: SHOP AIR: 100 PSIG,20 SCFM; PURGE AIR: 300 SCFM; HIGH PRESSURE AIR: 750 PSIG,10 SCFM,HIGH PRESSURE GN2: 200 PSIG,5 SCFM; TEST STATION PROVIDES TO UUT GN2: 50 PSIA; WATER: HOT WATER,40 PSIG,2 GPM,140 DEG F; COLD WATER: 40 PSIG,10 GPM,55 DEG F; COMPUTER CONTROLLED; 11.000 FT W,8.000 FT D,8.000 FT H; FIXED MOUNT VAC |
| FUNCTIONAL DESCRIPTION | USED FOR FAULT ISOLATION,AND FINAL SERVICE ACCEPTANCE ON ASSEMBLIES/SUB-ASSEMBLIES OF THE AUGMENTOR PUMP CONTROLLER |
| END ITEM IDENTIFICATION | F100-PW-220 ACFT ENGINE |