PartsTable
Technical Data Sheet
20782 ✓ Verified by PartsTable
Lindy · MRO · MRO_GENERAL
WHAT YOU NEED TO KNOW
Stranded for flexible routing, solid for conduit THHN/THWN dual-rated — check both tables
Ampacity depends on installation method
PRODUCT OVERVIEW

High speed scanning for retail, office or warehouse!<br>This very high quality single line laser scanner can be used in either hand-held or hands-free mode, making it the perfect solution for point of sale, stock control and logistics tracking applications. It features powerful scanning performance of up to 500 scans per second and advanced 'Z-SCAN' real-time scanning and hardware decoding technology for fast, accurate scanning and an unbeatable first read success rate.<br><br>The easy-to-hold grip makes it very comfortable to use while for hands-free operation a built-in auto scan feature allows it to scan automatically when used in the stand.<br>- Can be used in hand-held or hands-free modes<br>- Reads all common barcodes<br>- USB 1.1 interface with 2m cable<br>- High speed - up to 500 scans per second<br>- Built-in auto scan feature when used in hands-free mode<br>- LED Scan indicator and programmable beeper<br>- Ergonomic, robust design. This part is cataloged in the Federal Logistics Information System (FLIS) under NSN 6145-01-224-2451, indicating validated use in U.S.

government and defense logistics supply chains.

WHERE IT FITS
MRO MRO_GENERAL 20782
NSN: 6145-01-224-2451
FSC: 6145
CAGE: 97324 — CHAMPLAIN CABLE LEEDS CORPORATION (USA)
SPECIFICATIONS
colorBLACK FIRST POSITION JACKET CABLE
materialCOPPER ALLOY 101 OR COPPER ALLOY 102 CORE CONDUCTOR ALL CONDUCTORS
temp_rating-40.0 CELSIUS AND 105.0 CELSIUS DEGC
conductor_formSTRANDED ALL CONDUCTORS
voltage_rating600.0 MAXIMUM ROOT MEAN SQUARE (RMS) OPERATING VOLTAGE ALL CONDUCTORS
special_featuresOUTER JACKET CONFORMS TO MIL-I-631 TYPE F
surface_treatmentTIN CORE CONDUCTOR ALL CONDUCTORS
conductor_quantity38
round_conductor_size22 AWG ALL CONDUCTORS
cross-sectional_shape_styleROUND
strand_awg_size_per_conductor30 ALL CONDUCTORS
strand_quantity_per_conductor7 ALL CONDUCTORS
NSN6145-01-224-2451
COMPONENT DIAGRAM
WIRE / CABLE — AMPACITY DEPENDS ON INSTALLATION CROSS-SECTION JACKET WIRE SPECIFICATIONS Conductor Size: — Conductor Count: — Voltage Rating: — Insulation: — Temp Rating: — PN: 20782 · Lindy ⚠ VERIFY BEFORE ORDERING Ampacity depends on installation method — conduit ≠ free air ≠ underground. Same wire, different ratings. AWG sizing is inverse — smaller number = thicker wire (4 AWG > 12 AWG) ✓ BROKER TIP Stranded = flexible routing and vibration resistance. Solid = fixed conduit runs only. THHN/THWN = dual rated — check both dry and wet ampacity tables PARTSTABLE TECHNICAL DRAWING — NOT TO SCALE
KEY FEATURES
TEMP RATING: -40.0 CELSIUS AND 105.0 CELSIUS DEGC
MATERIAL: COPPER ALLOY 101 OR COPPER ALLOY 102 CORE CONDUCTOR ALL CONDUCTORS
COLOR CODING DOCUMENT: 3008-05869 DRAWING (THIS IS THE BASIC GOVERNING DRAWING, SUCH AS A CONTRACTOR DRAWING, ORIGINAL EQUIPMENT MANUFACTURER DRAWING, ETC.; EXCLUDES ANY SPECIFICATION, STANDARD OR OTHER DOCUMENT THAT MAY BE REFERENCED IN A BASIC GOVERNING DRAWING)
VOLTAGE RATING: 600.0 MAXIMUM ROOT MEAN SQUARE (RMS) OPERATING VOLTAGE ALL CONDUCTORS
STRAND QUANTITY PER CONDUCTOR: 7 ALL CONDUCTORS
ROUND CONDUCTOR SIZE: 22 AWG ALL CONDUCTORS
TECHNICAL CHARACTERISTICS (FLIS)
TEMP RATING-40.0 CELSIUS AND 105.0 CELSIUS DEGC
SPECIAL FEATURESOUTER JACKET CONFORMS TO MIL-I-631 TYPE F
MATERIALCOPPER ALLOY 101 OR COPPER ALLOY 102 CORE CONDUCTOR ALL CONDUCTORS
COLOR CODING DOCUMENT3008-05869 DRAWING (THIS IS THE BASIC GOVERNING DRAWING, SUCH AS A CONTRACTOR DRAWING, ORIGINAL EQUIPMENT MANUFACTURER DRAWING, ETC.; EXCLUDES ANY SPECIFICATION, STANDARD OR OTHER DOCUMENT THAT MAY BE REFERENCED IN A BASIC GOVERNING DRAWING)
MATERIALPLASTIC VINYL FIRST POSITION JACKET CABLE
VOLTAGE RATING600.0 MAXIMUM ROOT MEAN SQUARE (RMS) OPERATING VOLTAGE ALL CONDUCTORS
STRAND QUANTITY PER CONDUCTOR7 ALL CONDUCTORS
ROUND CONDUCTOR SIZE22 AWG ALL CONDUCTORS
MATERIAL DOCUMENT AND CLASSIFICATIONASTM B33 ASSN STD ALL MATERIAL RESPONSES CORE CONDUCTOR ALL CONDUCTORS
SURFACE TREATMENT DOCUMENT AND CLASSIFICATIONASTM B33-63 ASSN STD SINGLE TREATMENT RESPONSE CORE CONDUCTOR ALL CONDUCTORS
VERIFIED SUBSTITUTES & CROSS-REFERENCES 20
H442668-2Upgraded Successor
successor cross-reference
successor
H442668-1Upgraded Successor
successor cross-reference
successor
5244Upgraded Successor
successor cross-reference
successor
368301-1Interchangeable
interchangeable cross-reference
interchangeable
BA076TInterchangeable
interchangeable cross-reference
interchangeable
20782Interchangeable
interchangeable cross-reference
interchangeable
LIFECYCLE
StatusACTIVE
AvailabilityOEM and secondary market
RoHS CompliantEAR99Not HAZMAT
Ready to buy 20782?
Compare prices from verified sellers on eBay
Buy on eBay →
As an eBay Partner, PartsTable may earn a commission. Your price is not affected.
FREQUENTLY ASKED QUESTIONS
What is 20782?
20782 is a 20782 manufactured by Lindy. It is classified as a MRO (MRO_GENERAL).
What parts can replace 20782?
There are 20 known substitutes for 20782: H442668-2, H442668-1, 5244 and 17 more. Substitute compatibility should be verified for your specific system.
What is the NSN for 20782?
20782 is cataloged in the Federal Logistics Information System (FLIS) under NSN 6145-01-224-2451. This indicates validated use in U.S. government and defense supply chains.
Community Feedback
Comments (0)
No comments yet. Be the first to share what you know.
Leave a Comment
Comments are reviewed before appearing. You will receive an email to verify before your comment appears.

Request a Quote — 20782