PartsTable
Technical Data Sheet
17198 ✓ Verified by PartsTable
Clementoni · WIRE CABLE
WHAT YOU NEED TO KNOW
Stranded for flexible routing, solid for conduit THHN/THWN dual-rated — check both tables
Ampacity depends on installation method
PRODUCT OVERVIEW

CABLE ASSEMBLY,POWER,ELECTRICAL. Key specifications include material: STEEL, point_type: SPLIT, point_angle: 135.0 DEGREES NOMINAL, shank_style: STRAIGHT ROUND, temp_rating: 60.0 CELSIUS DEGC, flute_length: 3.438 INCHES NOMINAL IN. This product is currently in active production with full OEM support.

This part is cataloged in the Federal Logistics Information System (FLIS) under NSN 6150-00-063-3968, indicating validated use in U.S. government and defense logistics supply chains. Available through authorized enterprise resellers and TPM (Third Party Maintenance) channels.

Verify compatibility with your specific system configuration before ordering.

WHERE IT FITS
17198
NSN: 6150-00-063-3968
FSC: 6150
CAGE: 16428 — BELDEN WIRE & CABLE COMPANY LLC DBA BELDEN CDT ELECTRONICS DIVISION (USA)
SPECIFICATIONS
materialSTEEL
point_typeSPLIT
point_angle135.0 DEGREES NOMINAL
shank_styleSTRAIGHT ROUND
temp_rating60.0 CELSIUS DEGC
flute_length3.438 INCHES NOMINAL IN
conductor_formSTRANDED ALL CONDUCTORS
overall_length4.750 INCHES NOMINAL IN
shank_diameter0.344 INCHES NOMINAL IN
voltage_rating300.0 DC MAXIMUM RATED WORKING VOLTAGE ALL CONDUCTORS
special_featuresJOBBERS LG; FRACTIONAL SIZE 11/32
style_designatorJACK AND EXTERNAL CONNECTOR
NSN6150-00-063-3968
COMPONENT DIAGRAM
WIRE / CABLE — AMPACITY DEPENDS ON INSTALLATION CROSS-SECTION JACKET WIRE SPECIFICATIONS Conductor Size: — Conductor Count: — Voltage Rating: — Insulation: — Temp Rating: — PN: 17198 · Clementoni ⚠ VERIFY BEFORE ORDERING Ampacity depends on installation method — conduit ≠ free air ≠ underground. Same wire, different ratings. AWG sizing is inverse — smaller number = thicker wire (4 AWG > 12 AWG) ✓ BROKER TIP Stranded = flexible routing and vibration resistance. Solid = fixed conduit runs only. THHN/THWN = dual rated — check both dry and wet ampacity tables PARTSTABLE TECHNICAL DRAWING — NOT TO SCALE
KEY FEATURES
CROSS-SECTIONAL SHAPE STYLE: ROUND
STRAND QUANTITY PER CONDUCTOR: 41 ALL CONDUCTORS
VOLTAGE RATING: 300.0 DC MAXIMUM RATED WORKING VOLTAGE ALL CONDUCTORS
CONDUCTOR FORM: STRANDED ALL CONDUCTORS
CONDUCTOR QUANTITY: 3
TERMINATION TYPE: CONNECTOR RECEPTACLE BOTH ENDS ALL CONDUCTORS
MATERIAL: PLASTIC FIRST POSITION PRIMARY INSULATION ALL CONDUCTORS
TYPICAL APPLICATIONS
  • Server Internal Cabling
  • Data Center Cable Infrastructure
  • SAS/SATA Drive Connectivity
TECHNICAL CHARACTERISTICS (FLIS)
CROSS-SECTIONAL SHAPE STYLEROUND
STRAND QUANTITY PER CONDUCTOR41 ALL CONDUCTORS
VOLTAGE RATING300.0 DC MAXIMUM RATED WORKING VOLTAGE ALL CONDUCTORS
CONDUCTOR FORMSTRANDED ALL CONDUCTORS
CONDUCTOR QUANTITY3
TERMINATION TYPECONNECTOR RECEPTACLE BOTH ENDS ALL CONDUCTORS
MATERIALPLASTIC FIRST POSITION PRIMARY INSULATION ALL CONDUCTORS
MATERIALCOPPER CORE CONDUCTOR ALL CONDUCTORS
STRAND AWG SIZE PER CONDUCTOR30 ALL CONDUCTORS
STYLE DESIGNATORJACK AND EXTERNAL CONNECTOR
VERIFIED SUBSTITUTES & CROSS-REFERENCES 12
17198Interchangeable
interchangeable cross-reference
interchangeable
29358Interchangeable
interchangeable cross-reference
interchangeable
R10C 11/32Interchangeable
interchangeable cross-reference
interchangeable
46622Interchangeable
interchangeable cross-reference
interchangeable
550 11/32Interchangeable
interchangeable cross-reference
interchangeable
A1-3111-S-1449Interchangeable
interchangeable cross-reference
interchangeable
LIFECYCLE
StatusACTIVE
AvailabilityOEM and secondary market
RoHS CompliantEAR99Not HAZMAT
Ready to buy 17198?
Compare prices from verified sellers on eBay
Buy on eBay →
As an eBay Partner, PartsTable may earn a commission. Your price is not affected.
FREQUENTLY ASKED QUESTIONS
What is 17198?
17198 is a CABLE ASSEMBLY,POWER,ELECTRICAL manufactured by Clementoni.
What parts can replace 17198?
There are 12 known substitutes for 17198: 17198, 29358, R10C 11/32 and 9 more. Substitute compatibility should be verified for your specific system.
What is the NSN for 17198?
17198 is cataloged in the Federal Logistics Information System (FLIS) under NSN 6150-00-063-3968. This indicates validated use in U.S. government and defense supply chains.
Community Feedback
Comments (0)
No comments yet. Be the first to share what you know.
Leave a Comment
Comments are reviewed before appearing. You will receive an email to verify before your comment appears.

Request a Quote — 17198