16738632-004 — CABLE ASSEMBLY,POWER,ELECTRICAL

✓ Government record, cited
— · WIRE CABLE
PRODUCT OVERVIEW

16738632-004: CABLE ASSEMBLY,POWER,ELECTRICAL.

CABLE ASSEMBLY,POWER,ELECTRICAL. Key specifications include color: GREEN SECOND POSITION COVER SECOND CONDUCTOR, material: COPPER CORE CONDUCTOR ALL CONDUCTORS, conductor_form: STRANDED ALL CONDUCTORS, overall_length: 8.167 FEET FT, style_designator: JACK AND EXTERNAL CONNECTOR, termination_type: CONNECTOR EXTERNAL STRAIGHT SECOND END ALL CONDUCTORS. This part is cataloged in the U.S.

Government catalog under NSN 6150-01-207-8085, indicating validated use in U.S. government and defense logistics supply chains. Available through authorized enterprise resellers and TPM (Third Party Maintenance) channels.

Verify compatibility with your specific system configuration before ordering.

WHERE IT FITS
16738632-004
NSN: 6150-01-207-8085
FSC: 6150 — Miscellaneous Electric Power and Distribution Equipment
CAGE: 16428 — BELDEN WIRE & CABLE COMPANY LLC DBA BELDEN CDT ELECTRONICS DIVISION (USA)
SPECIFICATIONS
colorGREEN SECOND POSITION COVER SECOND CONDUCTOR
materialCOPPER CORE CONDUCTOR ALL CONDUCTORS
conductor_formSTRANDED ALL CONDUCTORS
overall_length8.167 FEET FT
style_designatorJACK AND EXTERNAL CONNECTOR
termination_typeCONNECTOR EXTERNAL STRAIGHT SECOND END ALL CONDUCTORS
conductor_quantity2
round_conductor_size18 AWG ALL CONDUCTORS
cross-sectional_shape_styleROUND
strand_awg_size_per_conductor34 ALL CONDUCTORS
strand_quantity_per_conductor41 ALL CONDUCTORS
cross_section_outside_diameter0.265 INCHES NOMINAL IN
NSN6150-01-207-8085
COMPONENT DIAGRAM
WIRE / CABLE — AMPACITY DEPENDS ON INSTALLATION CROSS-SECTION JACKET WIRE SPECIFICATIONS Conductor Size: — Conductor Count: — Voltage Rating: — Insulation: — Temp Rating: — PN: 16738632-004 · OEM ⚠ VERIFY BEFORE ORDERING Ampacity depends on installation method — conduit ≠ free air ≠ underground. Same wire, different ratings. AWG sizing is inverse — smaller number = thicker wire (4 AWG > 12 AWG) ✓ BROKER TIP Stranded = flexible routing and vibration resistance. Solid = fixed conduit runs only. THHN/THWN = dual rated — check both dry and wet ampacity tables PARTSTABLE TECHNICAL DRAWING — NOT TO SCALE
KEY FEATURES
•
ROUND CONDUCTOR SIZE: 18 AWG ALL CONDUCTORS
•
TERMINATION TYPE: CONNECTOR INTERNAL STRAIGHT FIRST END ALL CONDUCTORS
•
CONDUCTOR QUANTITY: 2
•
STRAND AWG SIZE PER CONDUCTOR: 34 ALL CONDUCTORS
•
STYLE DESIGNATOR: JACK AND EXTERNAL CONNECTOR
•
CROSS-SECTIONAL SHAPE STYLE: ROUND
TYPICAL APPLICATIONS
  • Server Internal Cabling
  • Data Center Cable Infrastructure
  • SAS/SATA Drive Connectivity
TECHNICAL CHARACTERISTICS
ROUND CONDUCTOR SIZE18 AWG ALL CONDUCTORS
TERMINATION TYPECONNECTOR INTERNAL STRAIGHT FIRST END ALL CONDUCTORS
TERMINATION TYPECONNECTOR EXTERNAL STRAIGHT SECOND END ALL CONDUCTORS
OVERALL LENGTH8.167 FEET FT
CONDUCTOR QUANTITY2
STRAND AWG SIZE PER CONDUCTOR34 ALL CONDUCTORS
STYLE DESIGNATORJACK AND EXTERNAL CONNECTOR
CROSS-SECTIONAL SHAPE STYLEROUND
CONDUCTOR FORMSTRANDED ALL CONDUCTORS
STRAND QUANTITY PER CONDUCTOR41 ALL CONDUCTORS
OTHER ITEMS IN FSC 6150 — Miscellaneous Electric Power and Distribution Equipment
Items in the same Federal Supply class. No interchangeability or substitution relationship is implied.
6150-00-000-0125 6150-00-000-0174 6150-00-000-0176 6150-00-000-0178 6150-00-000-0179 6150-00-000-0180 6150-00-001-1272 6150-00-001-1522
SUBSTITUTES & CROSS-REFERENCES

No substitute or cross-reference records for this part.

LIFECYCLE
NSN statusActive· U.S. Government catalog
Acquisition advice: Normally procured from the manufacturer (OEM)Demilitarization required — mutilation
Ready to buy 16738632-004?
Compare prices from verified sellers on eBay
Buy on eBay →
As an eBay Partner, PartsTable may earn a commission. Your price is not affected.
FREQUENTLY ASKED QUESTIONS
What is 16738632-004?
16738632-004 is a CABLE ASSEMBLY,POWER,ELECTRICAL.
What is the NSN for 16738632-004?
16738632-004 is cataloged in the U.S. Government catalog under NSN 6150-01-207-8085. This indicates validated use in U.S. government and defense supply chains.
Community Feedback
Leave a Comment
Comments are reviewed before appearing. You will receive an email to verify before your comment appears.

Request a Quote — 16738632-004