The CAPACITOR,FIXED,ELECTROLYTIC is a the manufacturer cache protection component designed to preserve data integrity during power loss events in enterprise server and storage controller environments. Key specifications include material: COPPER ALLOY 101 OR COPPER ALLOY 102 CORE CONDUCTOR ALL CONDUCTORS, conductor_form: STRANDED ALL CONDUCTORS, voltage_rating: 600.0 MAXIMUM ROOT MEAN SQUARE (RMS) OPERATING VOLTAGE ALL CONDUCTORS, surface_treatment: TIN CORE CONDUCTOR ALL CONDUCTORS, conductor_quantity: 14, round_conductor_size: 16 AWG ALL CONDUCTORS. This product is currently in active production with full OEM support.
This part is cataloged in the Federal Logistics Information System (FLIS) under NSN 6145-01-273-0073, indicating validated use in U.S. government and defense logistics supply chains. Available through authorized enterprise resellers and TPM (Third Party Maintenance) channels.
Verify compatibility with your specific system configuration before ordering.
| material | COPPER ALLOY 101 OR COPPER ALLOY 102 CORE CONDUCTOR ALL CONDUCTORS |
| conductor_form | STRANDED ALL CONDUCTORS |
| voltage_rating | 600.0 MAXIMUM ROOT MEAN SQUARE (RMS) OPERATING VOLTAGE ALL CONDUCTORS |
| special_features | SIXTH GROUPING ARRANGEMENT ELEVENTH AND TWELFTH CONDUCTOR THROUGH SEVENTH GROUPING ARRANGEMENT THIRTEENTH AND FOURTEENTH CONDUCTOR. PLASTIC,POLYOLEFIN IS IRRADIATED AND CROSS-LINKED |
| surface_treatment | TIN CORE CONDUCTOR ALL CONDUCTORS |
| conductor_quantity | 14 |
| round_conductor_size | 16 AWG ALL CONDUCTORS |
| cross-sectional_shape_style | ROUND |
| strand_awg_size_per_conductor | 29 ALL CONDUCTORS |
| strand_quantity_per_conductor | 19 ALL CONDUCTORS |
| cross_section_outside_diameter | 0.775 INCHES NOMINAL IN |
| conductor_sequence_within_groups | FIRST CONDUCTOR AND SECOND CONDUCTOR FIRST GROUP |
| NSN | 6145-01-273-0073 |
| CONDUCTOR SEQUENCE WITHIN GROUPS | NINTH CONDUCTOR AND TENTH CONDUCTOR FIFTH GROUP |
| CONDUCTOR ARRANGEMENT AND QUANTITY | 7 TWISTED PAIR |
| CONDUCTOR SEQUENCE WITHIN GROUPS | SEVENTH CONDUCTOR AND EIGHTH CONDUCTOR FOURTH GROUP |
| CONDUCTOR SEQUENCE WITHIN GROUPS | THIRD CONDUCTOR AND FOURTH CONDUCTOR SECOND GROUP |
| CONDUCTOR SEQUENCE WITHIN GROUPS | FIRST CONDUCTOR AND SECOND CONDUCTOR FIRST GROUP |
| MATERIAL | COPPER ALLOY 101 OR COPPER ALLOY 102 CORE CONDUCTOR ALL CONDUCTORS |
| CONDUCTOR SEQUENCE WITHIN GROUPS | FIFTH CONDUCTOR AND SIXTH CONDUCTOR THIRD GROUP |
| SURFACE TREATMENT DOCUMENT AND CLASSIFICATION | ASTM B33-63 ASSN STD SINGLE TREATMENT RESPONSE CORE CONDUCTOR ALL CONDUCTORS |
| CROSS SECTION OUTSIDE DIAMETER | 0.775 INCHES NOMINAL IN |
| CONDUCTOR QUANTITY | 14 |